Trial summary

With an aging population a prevalence of edentulous patients increased above 60 % among individuals aged ≥65 yr. Face mask ventilation of these edentulous patients is often difficult because of the inadequate fitting of the standard mask to the face. Read more about this study

Who is it for?
Ages 65 years and older
Conditions the study is for
Anaesthesia
What is being tested?
Group LMA Unique™ and Group LMA Supreme™
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteTurkey (Türkiye)
Study dates
Aug 2009to May 2010
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 65 years and older
  • All sexes
  • No healthy volunteers
  • Older adult

Who may be able to join

  • ASA I-III
  • 65 years and older

Who cannot join

  • Any neck or upper respiratory pathology
  • Those at risk of gastric content regurgitation/aspiration (previous upper gastro-intestina system surgery, known hiatus hernia, gastroesophageal reflux, history of peptic ulcer, full stomach, pregnancy)
  • Possibility of and those with history of difficult intubation (history of impossible intubation, Mallampati classification 3-4, sterno mental distance less than 12 cm, thyromental distance less than 6 cm, head extension less than 90 degrees, mouth opening less than 1.5 cm)
  • Those with low pulmonary compliance or high airway resistance (morbid obesity, lung disease)
  • Throat pain, dysphagia and dysphonia

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Dokuz Eylül University, School of Medicine, Department of Anesthesiology and Reanimation

    Izmi̇r, Narlıdere, 35320

Other trials in Turkey (Türkiye)

About this study

Official title: Comparison of The Laryngeal Mask Airway Supreme™ Versus Unique™ in Edentulous Geriatric Patients

With an aging population a prevalence of edentulous patients increased above 60 % among individuals aged ≥65 yr. Face mask ventilation of these edentulous patients is often difficult because of the inadequate fitting of the standard mask to the face. In addition, because of a reduction in muscle tone under general anesthesia, the air space in the oropharynx is reduced, and posterior displacement of the tongue, soft palate and epiglottis tend to close the airway. The laryngeal mask airway (LMA) provides a better alternative to the standard face mask if the facial contours of the patient are not suited to the standard face mask. It is more difficult to perform bag-mask ventilation in edentulous patients than in patients with intact dentition. The laryngeal mask airway (LMA) provides a better alternative to the standard face mask if the facial contours of the patient are not suited to the standard face mask.

We aimed to compare the routinely used laryngeal mask airway in our clinic, the LMA Unique™ with the newly released LMA Supreme™ in edentulous elderly patients for the success in first attempt insertion, ease and time of insertion, and oropharyngeal leak pressure.

Read the detailed description

After Ethical Committee approval and written informed consent were obtained, sixty edentulous patients (American Society of Anesthesiologists physical status (ASA) grade I-III, aged over 65 years) undergoing elective surgery were included into the study. Patients with dentures had to remove their dentures before surgery at the ward. The supraglottic airway device was inserted into each patient in a random order. A statistician independent of the clinical investigators generated the randomization sequence using a computerized program. Patients were excluded if they had a known or predicted difficult airway, a body mass index > 35 kg/m2, or were at risk of aspiration. All cases were conducted by anesthetists who had experience over 5 years of LMA insertion.

Demographic parameters, Mallampati classification and the duration of surgery were recorded. Patients were routinely monitored using ECG, non-invasive blood pressure measurement, pulse oximetry and end-tidal carbon dioxide tension. Depth of anesthesia was monitored with bispectral index (BIS).

Patients were premedicated with midazolam 0.02 mg/kg when venous access was obtained. After 3 min preoxygenation with 100 % oxygen via face mask, anesthesia was induced with fentanyl 1-2 µg/kg and propofol 1-2 mg/kg. When the BIS value was 40-60 the predetermined supraglottic airway device was inserted according to the manufacturer's recommendations. The supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O.

An effective airway was defined as the presence of normal thoracoabdominal movement and a square-wave end-tidal carbon dioxide trace. General anesthesia was maintained with sevoflurane, O2 and N2O.

Insertion time was defined as the time from picking up the airway device until connection to the airway circuit. Ease of insertion was graded by the attending anesthesiologist as easy, fair or difficult. If after three attempts insertion was still not successful, the other device was used. If insertion of the other device also failed the patient was endotracheally intubated.

Before the oropharyngeal leak test was carried out, the face of the patient was covered so that the observer was blinded to the airway device. The oropharyngeal leak pressure was determined by transiently stopping ventilation and closing the adjustable pressure-limiting valve with a fresh gas flow of 3 L/min until airway pressure reached a steady state and a voice of leakage was heard. The airway pressure was not allowed to exceed 40 cm H2O.

After successful placement of the LMA Supreme™, a 12 French gauge gastric catheter was inserted via the gastric channel.

Any episode of hypoxemia (SpO2 < 90%), aspiration or regurgitation,bronchospasm and airway obstruction were documented. After removal of the LMA, it was examined for the presence of visible blood.

In the postanesthesia care unit, a research assistant, who was blinded to the group allocation, interviewed the patients using a predetermined questionnaire to collect data on the postoperative pharyngolaryngeal adverse events. The presence or absence of sore throat, dysphonia and dysphagia was assessed at 1 and 24 h postoperatively.

Conditions
Anaesthesia
Being tested
Group LMA Unique™, Group LMA Supreme™
Keywords
Laryngeal mask airway, edentulous geriatric patient

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Group LMA Unique™Device

    Also called Laryngeal Mask Airway Unique, LMA Unique (The Laryngeal Mask Company Limited, Singapore)

    The supraglottic airway devices were deflated fully before insertion. After placement an effective airway was defined as the presence of normal thoracoabdominal movement and a square-wave end-tidal carbon dioxide trace.

  • Group LMA Supreme™Device

    Also called Laryngeal Mask Airway Supreme, Teleflex, The Laryngeal Mask Company Limited, Singapore

    The supraglottic airway devices were deflated fully before insertion.The supraglottic airway devices were deflated fully before insertion. After placement an effective airway was defined as the presence of normal thoracoabdominal movement and a square-wave end-tidal carbon dioxide trace.

Study groups in NCT02197377
Study groupRoleWhat they receive
Group LMA UniqueActive comparatorThe supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O.The oropharyngeal leak pressure was determined by transiently stopping ventilation and closing the adjustable pressure-limiting valve with a fresh gas flow of 3 L/min until airway pressure reached a steady state and a voice of leakage was heard. The airway pressure was not allowed to exceed 40 cm H2O.
Receives: Device: Group LMA Unique™
Group LMA SupremeExperimentalThe supraglottic airway devices were deflated fully before insertion. Size 4 LMA was used for those with a weight of 50-70 kg and size 5 LMA for those between 70-100 kg. After insertion, each device was inflated with a hand-held airway manometer (Rusch, Germany) to an intracuff pressure of 60 cm H2O.The oropharyngeal leak pressure was determined by transiently stopping ventilation and closing the adjustable pressure-limiting valve with a fresh gas flow of 3 L/min until airway pressure reached a steady state and a voice of leakage was heard. The airway pressure was not allowed to exceed 40 cm H2O.
Receives: Device: Group LMA Supreme™

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. First Attempt's Success Rate of Insertion

    Edentulous elderly patients for the success in first attempt insertion, ease and time of insertion (second).

    Measured: after anaesthesia induction

Secondary outcomes (1)
  1. Oropharyngeal Leak Pressure

    The aim of this study is to compare on the oropharyngeal leak pressure in LMA Unique™ and LMA Supreme™ applications

    Measured: before surgery

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Jul 2014 (estimated)
  2. Study startAug 2009
  3. Primary completionApr 2010
  4. Study completionMay 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Screening
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Investigator, Outcomes assessor
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02197377
Sponsor's protocol ID
178/2009
Status last verified
Dec 2017
First submitted
21 Jul 2014
Last updated
19 Oct 2018
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Group LMA Unique™ and Group LMA Supreme™ in people with Anaesthesia, run by Dokuz Eylul University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Oct 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 19 Oct 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

First Attempt's Success Rate of Insertion (time frame: after anaesthesia induction). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Oct 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in