AzTrials
AzTrials

CRCNCT02161549

Evaluation of the Motus Gl CleanUp System During Screening Colonoscopy

An observational study of CRC, run by Motus GI Medical Technologies Ltd at 1 site in Spain.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Motus Gl is developing a single-use device that attaches to a standard colonoscope, thereby integrating colon cleansing, screening and treatment into one procedure. The device creates turbulence within the colon using water jets. The colon's fecal fluids are evacuated by the system. Read more about this study

Who is it for?
Ages 50 to 69 yearsHealthy volunteers can take part
Conditions the study is for
CRC
What is being tested?
Motus Gl CleanUp System
Type of treatment
Medical device
How many people
71 participants
Where
1 siteSpain
Study dates
Jul 2012to Oct 2013
How long will I take part?
2 Days
Phase
Observational
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 50 to 69 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: subjects indicate for standard colonoscopy procedure (i.e., screening, diagnostic , surveillance)

Who may be able to join

  • Subjects in the age range of 50-69 years
  • Subjects who are considered for routine screening colonoscopy
  • Subjects with BMI within the range of 18.5-30
  • Subject is willing to sign informed consent form

Who cannot join

  • History of G diseases or history of Colorectal cancer (personal or family)
  • Previous major abdominal surgeries
  • Medical status ASA grater or equal to 3
  • Acute Gl symptoms, such as bleeding, unexplained weight loss, inflammatory bowel disease (lBD).
  • Patients taking anticoagulants (e.g., Coumadin, Heparin, Clopidrogrel)
  • Life-threatening condition
  • Subjects who are unable or unwilling to cooperate with study procedures
  • Severe Diverticula

Trial locations and contacts

1 site in 1 country.

Spain1 site
  • Clinica San Rafael

    Cadiz, 11002

Other trials in Spain

About this study

Motus Gl is developing a single-use device that attaches to a standard colonoscope, thereby integrating colon cleansing, screening and treatment into one procedure.

The device creates turbulence within the colon using water jets. The colon's fecal fluids are evacuated by the system.

Read the detailed description

63 eligible subjects who are allocated for a diagnostic screening colonoscopy were enrolled in the study. The assignment of the level of the bowel preparation agent was according to the physician decision. Following preparation, enrolled subjects were intubated and cleansed using a standard colonoscope with the Motus GI CleanUp device attached to it. At the end of the procedure, subjects were followed through discharge and at 48 hours post procedure for occurrence of adverse events.

40 subjects were enrolled under protocol Rev 1.0 used Motus GI CleanUp System Rev 1.0 31 subjects were enrolled under protocol Rev 2 used Motus GI CleanUp System Rev 1.5, due to improvement made to the study device including the following:

  1. One head that irrigates and evacuates instead of two heads
  2. Elimination of the grinding mechanism and the motor to reduce the pipes' diameters while keeping the same flow rate.
  3. System adjustment to the above changes including updated software version.
Conditions
CRC
Being tested
Motus Gl CleanUp System

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Motus Gl CleanUp SystemDevice

Study groups in NCT02161549
Study groupRoleWhat they receive
Colonoscopy with MotusGi CleanUp System Rev 1.0subjects indicated for colonoscopy procedure with CleanUp System Rev 1.0 , enrolled under protocol Rev 1.0
Receives: Device: Motus Gl CleanUp System
Colonoscopy with MotusGi CleanUp System Rev 1.5subjects indicated for colonoscopy procedure with CleanUp System Rev 1.5 , enrolled under protocol Rev 2.0
Receives: Device: Motus Gl CleanUp System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mean Score of Boston Bowel Preparation Scale (BBPS) Index Prior and After the Use of MotusGI CleanUp System

    Human colon has 3 segments and each segment can be scored 0 (unprepared colon) - 3 (clean colon). average of all colon segments BBPS score after the use of MotusGI CleanUp System

    Measured: during colonoscopy procedure after cleansing with CleanUp System

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted11 Jun 2014 (estimated)
  2. Study startJul 2012
  3. Primary completionOct 2013
  4. Study completionOct 2013

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
71 participants (actual)
Target duration
2 Days
IDs, dates and publications
ClinicalTrials.gov ID
NCT02161549
Sponsor's protocol ID
CP-MCU-SP-1211
Status last verified
Mar 2017
First submitted
10 Jun 2014
Last updated
20 Sep 2017
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of CRC, run by Motus GI Medical Technologies Ltd at 1 site in Spain.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 20 Sep 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Spain. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 15 Jun 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Mean Score of Boston Bowel Preparation Scale (BBPS) Index Prior and After the Use of MotusGI CleanUp System (time frame: during colonoscopy procedure after cleansing with CleanUp System). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Sep 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in