Atrial FibrillationAWARENCT02150902
Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence
A study testing Wide area circumferential catheter ablation and Augmented- wide area circumferential ablation procedure in people with Atrial Fibrillation, run by Ottawa Heart Institute Research Corporation at 11 sites in Canada.
Trial summary
Atrial fibrillation (AF) is an abnormal heart rhythm in which the top chambers of the heart beat very fast. AF catheter ablation is a known technique to convert heart rhythm from AF to normal rhythm. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Atrial Fibrillation
- What is being tested?
- Wide area circumferential catheter ablation and Augmented- wide area circumferential ablation procedure
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 411 participants
- Where
- 11 sitesCanada
- Study dates
- Mar 2015to 27 Nov 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age ≥18 years
- Subjects must have symptomatic Paroxysmal AF that is refractory to at least one class I or Class III antiarrhythmic medication OR be intolerant of antiarrhythmic medications OR prefer not to trial antiarrhythmic medications
- At least one episode of AF documented on 12-lead ECG, Holter monitor or Loop recorder.
- Subjects must be able to provide informed consent
Who cannot join
- Subjects with persistent or permanent AF
- History of previous catheter or surgical ablation for AF
- Presence of known intracardiac thrombus
- Subjects with contraindication to systemic oral anticoagulation therapy, including a history of Heparin Induced Thrombocytopenia
- Subjects with reversible causes of AF
- Subjects with significant valve disease (moderate or severe mitral/aortic stenosis or regurgitation)
Show all 9Show fewer
- Subjects with known adverse reaction to adenosine
- Subjects with congenital heart disease
- Subjects that are pregnant
Trial locations and contacts
11 sites in 1 country.
11 sites in 1 country
Canada11 sites
University of Calgary-Foothills Campus
Calgary, Alberta, T2N 4Z6
QE II Health Sciences Centre
Halifax, Nova Scotia, B3H 3A7
McGill University Health Center
Montreal, Quebec, H3G 1A4
CIUSSSNIM-Hopital du Sacre-Coeur de Montreal
Montreal, Quebec, H4J 1C5
University of Ottawa Heart Institute
Ottawa, Ontario, K1Y 4W7
Institut universitaire de cardiologie et de pneumologie de Quebec
Québec, Quebec, G1V 4G5
Centre hospitalier universitaire de Sherbrooke (CHUS)
Sherbrooke, Quebec, J1H 5N4
St. Michael"s Hospital
Toronto, Ontario, M5B 1W8
Toronto General Hospital-University Health Network
Toronto, Ontario, M5G 2C4
Sunnybrook Health Sciences Centre
Toronto, Ontario
Victoria Cardiac Arrhythmia Trials Inc.
Victoria, British Columbia, V8T 1Z4
About this study
Official title: AUGMENTED WIDE AREA CIRCUMFERENTIAL CATHETER ABLATION FOR REDUCTION OF ATRIAL FIBRILLATION RECURRENCE - A RANDOMIZED CLINICAL TRIAL (The AWARE Trial)
Atrial fibrillation (AF) is an abnormal heart rhythm in which the top chambers of the heart beat very fast. AF catheter ablation is a known technique to convert heart rhythm from AF to normal rhythm. The technique sends out electrical energy through a catheter (long thin round solid tubes) to destroy the heart tissues in a focused area where AF is starting. This technique is practiced at many hospitals, including the Heart Institute, and is not experimental.
The AWARE study will compare two techniques of AF catheter ablation:
Read more
- Ablation of tissues in wide circular bands around the opening of the pulmonary veins (bring blood back from lungs) in the left upper chamber of the heart. A medicine called adenosine will be given to unmask any incompletely ablated area. Additional ablations will be given if required. This is standard procedure.
- Same as above but adenosine will not be used. Instead, additional ablation of a second circular band of tissues around the opening of the pulmonary veins will be given. This additional ablation is not standard procedure and is considered experimental.
The Investigators are testing if adding more ablation sites will help maintain normal heart rhythm and reduce the rate of return to AF. The study will compare the occurrence of medical events and complications between the two groups.
Identical supplies and equipment used in both techniques have been approved by Health Canada. Adenosine is currently approved by Health Canada for the treatment and diagnosis of arrhythmias.
396 participants from study sites across Canada will be randomly assigned "similar to flipping a coin" to treatment group 1 or group 2.
After the ablation, participants will have study follow-up at 3, 6 and 12 months. All participant's will be followed for a minimum of 12 months.
Read the detailed description
Clinical relevance:
The problem of PV reconnection and recurrent AF after catheter ablation for paroxysmal AF is one of the important challenges faced by treating physicians.
Rationale:
The understanding of the role contact force plays in adequate lesion formation during catheter ablation and the fact that this may reduce pulmonary vein (PV) reconnection and AF recurrence is an exciting advance in the field of catheter ablation for AF. A few small clinical trials have demonstrated the safety and feasibility of contact force guided catheter ablation in reducing PV reconnection and AF recurrence. There is a clear need for well designed and adequately powered clinical trials to evaluate the effectiveness of this new strategy. The investigators have developed a novel "augmented" CF guided augmented ablation strategy and will test this against the current clinical gold standard ablation technique.
Objective:
Using contact force (CF) technology, our intention is to evaluate an "augmented- wide area circumferential catheter ablation strategy" that could potentially reduce the incidence of pulmonary vein reconnection and AF recurrence after catheter ablation in patients with paroxysmal AF.
Hypothesis:
In patients with symptomatic paroxysmal AF an augmented-wide area circumferential catheter ablation strategy will result in fewer electrocardiographically documented atrial arrhythmias (AF, atrial flutter and atrial tachycardia) recurrences compared to conventional wide-area catheter ablation.
All subjects in the control arm of the trial will undergo wide area circumferential catheter ablation (WACA; lesions delivered 1-2 cm away from the pulmonary vein ostium) around all four pulmonary veins to the endpoint of electrical isolation (demonstrated by entry and exit block using differential pacing). Catheter ablation will be performed using CF and VISITAG guidance (average CF >10g, Force time integral (FTI) > 500 g-sec and minimum ablation duration >10 sec). Dormant PV conduction will be tested using adenosine, after completion of the lesion set, and additional lesions will be delivered to eliminate dormant PV conduction.
In the experimental arm of the trial all subjects will undergo WACA as described above; however without adenosine testing. In addition these subjects will receive "augmented" ablation lesions, guided by CF feedback, on the outer aspect of the first WACA lesion set. Our hypothesis is that this "belts and suspender" strategy of redundant, CF guided antral ablation lesions will result in a wider band of irreversible atrial muscle and cardiac autonomic ganglionated-plexi damage. It is our expectation that the augmented WACA strategy will result in more durable PV isolation and thereby significantly reduce AF recurrence.
Trial Design:
This trial is a multicentre, prospective, randomized, blinded endpoint trial (PROBE) design. Subjects who satisfy the inclusion and exclusion criteria will be enrolled in the clinical trial. Subjects will be randomized (1:1) to either the control arm (WACA only) or the experimental arm (augmented- WACA). Patients randomized to the experimental arm will go on to have augmented-WACA. The first 90 days after catheter ablation will be considered a "blanking-period" and atrial tachyarrhythmias (AF, Atrial Flutter [AFl] or Atrial Tachycardia [AT]) occurring during this period will be documented. However, these will not be considered treatment failures. Patient accrual will occur over a 24-month period and each subject will have a minimum follow-up period of 12 months. The total duration of the trial will be 36-months (24 months for accrual and a minimum of 12 months of follow up for each subject). Patients will be followed at 3, 6, and 12 months, with 14 day continuous ambulatory ECG monitoring done at each follow up visit. A total of three questionnaires will be administered throughout the study, each at a specific time point. The Quality of Life (EQ-5D) and CCS-Severity of AF scale will be completed together, prior to ablation and at the final follow-up visit. The patient satisfaction score will be completed at the final follow-up visit. All participants will be followed for a minimum of 12 months.
- Conditions
- Atrial Fibrillation
- Being tested
- Wide area circumferential catheter ablation, Augmented- wide area circumferential ablation procedure
- Keywords
- Catheter ablation for atrial fibrillation, treatment for atrial fibrillation, comparison of catheter ablation techniques for atrial fibrillation
- Medical subject headings
- Atrial Fibrillation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Wide area circumferential catheter ablationProcedure or surgery
Also called WACA
All subjects in the control arm of the trial will undergo wide area circumferential catheter ablation (WACA; lesions delivered 1-2 cm away from the pulmonary vein ostium) around all four pulmonary veins to the endpoint of electrical isolation (demonstrated by entry and exit block using differential pacing). Catheter ablation will be performed using contact force (CF) and electroanatomical mapping system guidance (average CF >10g, FTI > 500 g-sec and minimum ablation duration >10 sec). Dormant pulmonary vein conduction will be tested using adenosine, after completion of the lesion set, and additional lesions will be delivered to eliminate dormant PV conduction.
Augmented- wide area circumferential ablation procedureProcedure or surgery
Also called Augmented WACA
Subjects in this group will have WACA performed as described for WACA. Following completion of the WACA procedure a second set of circumferential ablation lesions will be delivered around the first set of ablation lesions. The ablation catheter tip will be positioned at each of the ablation lesions along the first WACA line and then moved away (from the PV ostia) until healthy, non ablated tissue is recorded from the catheter tip. Energy will be delivered using CF and FTI data as described previously. Once the first WACA ablation line has been completely duplicated the procedure will be deemed complete. In case PV isolation is not achieved after the first WACA lesion set repeat electrophysiologic testing will be performed to determine whether the augmented-WACA procedure was successful in achieving PV isolation.
| Study group | Role | What they receive |
|---|---|---|
| Augmented- WACA | Experimental | Augmented- wide area circumferential catheter ablation for atrial fibrillation Receives: Procedure: Augmented- wide area circumferential ablation procedure |
| WACA | Active comparator | Wide area circumferential catheter ablation procedure for atrial fibrillation Receives: Procedure: Wide area circumferential catheter ablation |
What is being measured
The primary outcome is the main question the study is designed to answer.
Time to First Recurrence of any ECG documented AF, AFl or AT
Time to first recurrence of any ECG documented AF, AFl or AT (symptomatic or asymptomatic) occurring between days 91 and 364 after catheter ablation in the absence of Class I or III antiarrhythmic drug therapy.
Measured: between days 91 and 364 after catheter ablation
Secondary outcomes (8)
The need for repeat catheter ablation procedure
The need for repeat catheter ablation procedure because of documented recurrence of symptomatic AF, AFl or AT
Measured: days 91 and 364 after catheter ablation
ECG documented AF
Incidence of any ECG documented AF (symptomatic or asymptomatic) during the first 90 days after catheter ablation
Measured: during the first 90 days after catheter ablation
emergency department visits or hospitalizations
The need for emergency department visits or hospitalizations
Measured: from randomization to day 364
procedure related complications
Composite safety endpoints- procedure related complications (Stroke, PV stenosis, Pericarditis, Cardiac perforation, Atrio-esophageal fistula, Major bleeding) and/or death.
Measured: from ablation to day 364
Quality of Life measurement using (EQ-5 and Canadian Cardiovascular Society-Severity of AF scales)
Quality of Life (EQ-5 and Canadian Cardiovascular Society-Severity of AF scales)
Measured: from randomization to day 364
Total procedure duration
total ablation procedure duration in minutes
Measured: day of the ablation procedure
Total radiation exposure during the procedure
Dose area product in McGy.cm2 and cumulative skin dose in mGv
Measured: day of the ablation procedure
Health Economic Analysis
Health care related costs
Measured: from randomization to day 364
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted30 May 2014 (estimated)
- Study startMar 2015
- Primary completion27 Nov 2026 (estimated)
- Study completion27 Nov 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Atrial FibrillationStudies of the same condition, open and under way.
- More trials run by Ottawa Heart Institute Research CorporationThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 411 participants (actual)
Sponsor and investigators
- Lead sponsor
- Ottawa Heart Institute Research Corporation
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Girish Nair, MD, Principal investigator, Ottawa Heart Institute Research Corporation
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02150902
- Sponsor's protocol ID
- IRIS 2771
- Other IDs
- 201610PJT-376677
- Acronym
- AWARE
- Status last verified
- Apr 2026
- First submitted
- 27 May 2014
- Last updated
- 1 May 2026
- Results posted
- No
- Data monitoring committee
- Yes
Publications
Nair GM, Birnie DH, Nery PB, Redpath CJ, Sarrazin JF, Roux JF, Parkash R, Bernier M, Sterns LD, Sapp J, Novak P, Veenhuyzen G, Morillo CA, Singh SM, Sadek MM, Golian M, Klein A, Sturmer M, Chauhan VS, Angaran P, Green MS, Bernick J, Wells GA, Essebag V. Standard vs Augmented Ablation of Paroxysmal Atrial Fibrillation for Reduction of Atrial Fibrillation Recurrence: The AWARE Randomized Clinical Trial. JAMA Cardiol. 2023 May 1;8(5):475-483. doi: 10.1001/jamacardio.2023.0212.
PubMed 36947030Nair GM, Birnie DH, Wells GA, Nery PB, Redpath CJ, Sarrazin JF, Roux JF, Parkash R, Bernier M, Sterns LD, Novak P, Veenhuyzen G, Morillo CA, Singh SM, Sturmer M, Chauhan VS, Angaran P, Essebag V. Augmented wide area circumferential catheter ablation for reduction of atrial fibrillation recurrence (AWARE) trial: Design and rationale. Am Heart J. 2022 Jun;248:1-12. doi: 10.1016/j.ahj.2022.02.009. Epub 2022 Feb 24.
PubMed 35219715
Study at a glance
From the registry record, last updated by the sponsor on 1 May 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- AUGMENTED WIDE AREA CIRCUMFERENTIAL CATHETER ABLATION FOR REDUCTION OF ATRIAL FIBRILLATION RECURRENCE - A RANDOMIZED CLINICAL TRIAL (The AWARE Trial)
- ClinicalTrials.gov ID
- NCT02150902
- Acronym / sponsor ID
- AWARE / IRIS 2771
- Conditions
- Atrial Fibrillation
- Keywords
- Catheter ablation for atrial fibrillation, treatment for atrial fibrillation, comparison of catheter ablation techniques for atrial fibrillation
- Study type
- Interventional
- Recruitment status
- Active, not recruiting
- Enrolment
- 411 participants (actual)
- Lead sponsor
- Ottawa Heart Institute Research CorporationUniversity, hospital or other
- Study start
- Mar 2015
- Primary completion
- 27 Nov 2026 (estimated)
- Study completion
- 27 Nov 2026 (estimated)
- First posted
- 30 May 2014 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Atrial fibrillation (AF) is an abnormal heart rhythm in which the top chambers of the heart beat very fast. AF catheter ablation is a known technique to convert heart rhythm from AF to normal rhythm. The technique sends out electrical energy through a catheter (long thin round solid tubes) to destroy the heart tissues in a focused area where AF is starting. This technique is practiced at many hospitals, including the Heart Institute, and is not experimental.
The AWARE study will compare two techniques of AF catheter ablation:
- Ablation of tissues in wide circular bands around the opening of the pulmonary veins (bring blood back from lungs) in the left upper chamber of the heart. A medicine called adenosine will be given to unmask any incompletely ablated area. Additional ablations will be given if required. This is standard procedure.
- Same as above but adenosine will not be used. Instead, additional ablation of a second circular band of tissues around the opening of the pulmonary veins will be given. This additional ablation is not standard procedure and is considered experimental.
The Investigators are testing if adding more ablation sites will help maintain normal heart rhythm and reduce the rate of return to AF. The study will compare the occurrence of medical events and complications between the two groups.
Identical supplies and equipment used in both techniques have been approved by Health Canada. Adenosine is currently approved by Health Canada for the treatment and diagnosis of arrhythmias.
396 participants from study sites across Canada will be randomly assigned "similar to flipping a coin" to treatment group 1 or group 2.
After the ablation, participants will have study follow-up at 3, 6 and 12 months. All participant's will be followed for a minimum of 12 months.
Detailed description
Clinical relevance:
The problem of PV reconnection and recurrent AF after catheter ablation for paroxysmal AF is one of the important challenges faced by treating physicians.
Rationale:
The understanding of the role contact force plays in adequate lesion formation during catheter ablation and the fact that this may reduce pulmonary vein (PV) reconnection and AF recurrence is an exciting advance in the field of catheter ablation for AF. A few small clinical trials have demonstrated the safety and feasibility of contact force guided catheter ablation in reducing PV reconnection and AF recurrence. There is a clear need for well designed and adequately powered clinical trials to evaluate the effectiveness of this new strategy. The investigators have developed a novel "augmented" CF guided augmented ablation strategy and will test this against the current clinical gold standard ablation technique.
Objective:
Using contact force (CF) technology, our intention is to evaluate an "augmented- wide area circumferential catheter ablation strategy" that could potentially reduce the incidence of pulmonary vein reconnection and AF recurrence after catheter ablation in patients with paroxysmal AF.
Hypothesis:
In patients with symptomatic paroxysmal AF an augmented-wide area circumferential catheter ablation strategy will result in fewer electrocardiographically documented atrial arrhythmias (AF, atrial flutter and atrial tachycardia) recurrences compared to conventional wide-area catheter ablation.
All subjects in the control arm of the trial will undergo wide area circumferential catheter ablation (WACA; lesions delivered 1-2 cm away from the pulmonary vein ostium) around all four pulmonary veins to the endpoint of electrical isolation (demonstrated by entry and exit block using differential pacing). Catheter ablation will be performed using CF and VISITAG guidance (average CF >10g, Force time integral (FTI) > 500 g-sec and minimum ablation duration >10 sec). Dormant PV conduction will be tested using adenosine, after completion of the lesion set, and additional lesions will be delivered to eliminate dormant PV conduction.
In the experimental arm of the trial all subjects will undergo WACA as described above; however without adenosine testing. In addition these subjects will receive "augmented" ablation lesions, guided by CF feedback, on the outer aspect of the first WACA lesion set. Our hypothesis is that this "belts and suspender" strategy of redundant, CF guided antral ablation lesions will result in a wider band of irreversible atrial muscle and cardiac autonomic ganglionated-plexi damage. It is our expectation that the augmented WACA strategy will result in more durable PV isolation and thereby significantly reduce AF recurrence.
Trial Design:
This trial is a multicentre, prospective, randomized, blinded endpoint trial (PROBE) design. Subjects who satisfy the inclusion and exclusion criteria will be enrolled in the clinical trial. Subjects will be randomized (1:1) to either the control arm (WACA only) or the experimental arm (augmented- WACA). Patients randomized to the experimental arm will go on to have augmented-WACA. The first 90 days after catheter ablation will be considered a "blanking-period" and atrial tachyarrhythmias (AF, Atrial Flutter [AFl] or Atrial Tachycardia [AT]) occurring during this period will be documented. However, these will not be considered treatment failures. Patient accrual will occur over a 24-month period and each subject will have a minimum follow-up period of 12 months. The total duration of the trial will be 36-months (24 months for accrual and a minimum of 12 months of follow up for each subject). Patients will be followed at 3, 6, and 12 months, with 14 day continuous ambulatory ECG monitoring done at each follow up visit. A total of three questionnaires will be administered throughout the study, each at a specific time point. The Quality of Life (EQ-5D) and CCS-Severity of AF scale will be completed together, prior to ablation and at the final follow-up visit. The patient satisfaction score will be completed at the final follow-up visit. All participants will be followed for a minimum of 12 months.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Augmented- WACA | Experimental | Procedure: Augmented- wide area circumferential ablation procedureAugmented- wide area circumferential catheter ablation for atrial fibrillation |
| WACA | Active comparator | Procedure: Wide area circumferential catheter ablationWide area circumferential catheter ablation procedure for atrial fibrillation |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Age ≥18 years
- Subjects must have symptomatic Paroxysmal AF that is refractory to at least one class I or Class III antiarrhythmic medication OR be intolerant of antiarrhythmic medications OR prefer not to trial antiarrhythmic medications
- At least one episode of AF documented on 12-lead ECG, Holter monitor or Loop recorder.
- Subjects must be able to provide informed consent
Key exclusion criteria (9 listed)
- Subjects with persistent or permanent AF
- History of previous catheter or surgical ablation for AF
- Presence of known intracardiac thrombus
- Subjects with contraindication to systemic oral anticoagulation therapy, including a history of Heparin Induced Thrombocytopenia
- Subjects with reversible causes of AF
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Wide area circumferential catheter ablationAlso: WACAAll subjects in the control arm of the trial will undergo wide area circumferential catheter ablation (WACA; lesions delivered 1-2 cm away from the pulmonary vein ostium) around all four pulmonary veins to the endpoint of electrical isolation (demonstrated by entry and exit block using differential pacing). Catheter ablation will be performed using contact force (CF) and electroanatomical mapping system guidance (average CF >10g, FTI > 500 g-sec and minimum ablation duration >10 sec). Dormant pulmonary vein conduction will be tested using adenosine, after completion of the lesion set, and additional lesions will be delivered to eliminate dormant PV conduction. | Procedure or surgery | WACA |
| Augmented- wide area circumferential ablation procedureAlso: Augmented WACASubjects in this group will have WACA performed as described for WACA. Following completion of the WACA procedure a second set of circumferential ablation lesions will be delivered around the first set of ablation lesions. The ablation catheter tip will be positioned at each of the ablation lesions along the first WACA line and then moved away (from the PV ostia) until healthy, non ablated tissue is recorded from the catheter tip. Energy will be delivered using CF and FTI data as described previously. Once the first WACA ablation line has been completely duplicated the procedure will be deemed complete. In case PV isolation is not achieved after the first WACA lesion set repeat electrophysiologic testing will be performed to determine whether the augmented-WACA procedure was successful in achieving PV isolation. | Procedure or surgery | Augmented- WACA |
Primary outcome
Time to First Recurrence of any ECG documented AF, AFl or AT
Time frame: between days 91 and 364 after catheter ablation
Time to first recurrence of any ECG documented AF, AFl or AT (symptomatic or asymptomatic) occurring between days 91 and 364 after catheter ablation in the absence of Class I or III antiarrhythmic drug therapy.
8 secondary outcomes
The need for repeat catheter ablation procedure
Time frame: days 91 and 364 after catheter ablation
ECG documented AF
Time frame: during the first 90 days after catheter ablation
emergency department visits or hospitalizations
Time frame: from randomization to day 364
procedure related complications
Time frame: from ablation to day 364
Quality of Life measurement using (EQ-5 and Canadian Cardiovascular Society-Severity of AF scales)
Time frame: from randomization to day 364
Total procedure duration
Time frame: day of the ablation procedure
Total radiation exposure during the procedure
Time frame: day of the ablation procedure
Health Economic Analysis
Time frame: from randomization to day 364
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 1 May 2026.
- Derived from this study: PubMed 36947030Nair GM, Birnie DH, Nery PB, Redpath CJ, Sarrazin JF, Roux JF, Parkash R, Bernier M, Sterns LD, Sapp J, Novak P, Veenhuyzen G, Morillo CA, Singh SM, Sadek MM, Golian M, Klein A, Sturmer M, Chauhan VS, Angaran P, Green MS, Bernick J, Wells GA, Essebag V. Standard vs Augmented Ablation of Paroxysmal Atrial Fibrillation for Reduction of Atrial Fibrillation Recurrence: The AWARE Randomized Clinical Trial. JAMA Cardiol. 2023 May 1;8(5):475-483. doi: 10.1001/jamacardio.2023.0212.
- Derived from this study: PubMed 35219715Nair GM, Birnie DH, Wells GA, Nery PB, Redpath CJ, Sarrazin JF, Roux JF, Parkash R, Bernier M, Sterns LD, Novak P, Veenhuyzen G, Morillo CA, Singh SM, Sturmer M, Chauhan VS, Angaran P, Essebag V. Augmented wide area circumferential catheter ablation for reduction of atrial fibrillation recurrence (AWARE) trial: Design and rationale. Am Heart J. 2022 Jun;248:1-12. doi: 10.1016/j.ahj.2022.02.009. Epub 2022 Feb 24.
Related trials for Atrial Fibrillation
Active, not recruiting
Horizon 360 Protocol for the Treatment of Paroxysmal Atrial Fibrillation With the Sphere-360™ Catheter and Affera™ Mapping and Ablation System (Horizon 360)
Paroxysmal AF
Active, not recruitingObservational study
Concomitant Left Atrial Appendage Closure and Pulsed Field Ablation-Asia
Concomitant Procedures, Atrial Fibrillation
Active, not recruiting
CONVERGE Post-Approval Study (PAS)
Chronic Atrial Fibrillation
Recruiting
Early Closure of Left Atrial Appendage for Patients With Atrial Fibrillation and Ischemic Stroke Despite Anticoagulation Therapy
Ischemic Stroke, Atrial Fibrillation
RecruitingPhase 2
Safety in Adult Participants With Atrial Fibrillation Who Are Treated With Anticoagulation
Atrial Fibrillation (AF)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Girish Nair, MD principal investigator
Ottawa Heart Institute Research Corporation
11 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Wide area circumferential catheter ablation and Augmented- wide area circumferential ablation procedure in people with Atrial Fibrillation, run by Ottawa Heart Institute Research Corporation at 11 sites in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 1 May 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 11 sites in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Time to First Recurrence of any ECG documented AF, AFl or AT (time frame: between days 91 and 364 after catheter ablation). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02150902, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 May 2026.