Atrial FlutterNCT02089672

RF Lesion Monitoring With 8mm IntellaTip MiFi XP

An observational study of Atrial Flutter and Arrhythmia, run by Emory University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Abnormal heart rhythms or arrhythmias are often managed by a procedure in which a catheter is introduced into the heart. These catheters can then cauterize abnormally functioning portions of the heart muscle with the hope of returning the heart to a more effective rhythm. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Atrial Flutter, Arrhythmia
What is being tested?
Catheter ablation
Type of treatment
Medical device
How many people
30 participants
Where
1 siteUnited States
Study dates
Apr 2014to Nov 2015
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Enrollment will include 25 patients undergoing a radiofrequency ablation procedure in which ablation of the cavotricuspid isthmus is planned.

Who may be able to join

  • Any adult undergoing an atrial flutter ablation

Who cannot join

  • -

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Emory University Hospital

    Atlanta, Georgia, 30322

Other trials in United States

About this study

Official title: Radiofrequency Ablation Lesion Monitoring Using Imbedded Micro-Electrodes Versus Standard Bipolar Electrograms

Abnormal heart rhythms or arrhythmias are often managed by a procedure in which a catheter is introduced into the heart. These catheters can then cauterize abnormally functioning portions of the heart muscle with the hope of returning the heart to a more effective rhythm. In the process of performing such a procedure, called a catheter ablation, an operator must be able to accurately sense electrical activity displayed on computer screens in different parts of the heart, provide sufficient localized energy to the abnormally behaving tissue (ideally without damaging uninvolved heart structures), and accurately reassess the electrical activity of the heart to ensure the spot in the heart has been cauterized.

When sensing electrical activity of the heart, specialized catheters produce recordings on a computer screen known as electrograms (EGM). To produce this recording conventional catheters commonly use a positive and negative electrode, from which the difference between the two provides the EGM. The distance between the two electrodes varies from device to device. The greater the distance between them, the less accurate the measurement of local electrical activity becomes. This may result in poorly localized or excessive use of energy that could be damaging to normal heart structures or put the patient at risk for the return or development of additional arrhythmias. The IntellaTip MiFi catheter has been constructed with a specialized sensing tip that uses "microelectrodes" that are relatively close in proximity (<1 mm apart) with the hope of improving the sensing capability of the device.

This study will analyze the signals obtained from this FDA-approved catheter in people undergoing a catheter ablation procedure. The study will examine signals after the procedure is finished and will not prolong or differ the process from a standard ablation procedure. The goal of this study is to determine the ability of the microelectrodes to distinguish ablated, or cauterized versus non-cauterized tissue.

Read the detailed description

This trial is an operator-blinded, acute, single-visit observational trial in humans. Enrollment will include 25 patients undergoing a radiofrequency ablation procedure in which ablation of the cavotricuspid isthmus is planned. Electrogram characteristics of the small, imbedded pin electrodes will be compared to standard bipolar EGMs utilizing the ablation tip electrode and ring. Absolute voltage, voltage reduction, and frequency spectra will be examined before, during, and after ablation. EGM characteristics of standard and "ultra-local" recordings will be compared in their ability to accurately identify an effective RF lesion as defined below.

Being tested
Catheter ablation
Medical subject headings
Atrial Flutter, Arrhythmias, Cardiac

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Catheter ablationDevice

    Also called 8mm IntellaTip MiFi XP ablation catheter

    This is observational trial studying the effects of a standard intervention of a catheter ablation procedure.

Study groups in NCT02089672
Study groupRoleWhat they receive
Atrial flutter patientsAtrial flutter patients undergoing catheter ablation
Receives: Device: Catheter ablation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Total bipolar electrogram amplitude using tip to ring and pin to pin configurations

    Measured: Acute, averaged one hour during ablation. Measured postoperatively.

Secondary outcomes (1)
  1. Total number of seconds per isthmus ablation spent in excess of the post-hoc identified complete lesion time.

    Measured: Acute, averaged one hour during ablation. Measured postoperatively

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Mar 2014 (estimated)
  2. Study startApr 2014
  3. Primary completionNov 2015
  4. Study completionNov 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Retrospective
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02089672
Sponsor's protocol ID
IRB00069674
Other IDs
ISRCRM90003
Status last verified
Nov 2015
First submitted
8 Feb 2014
Last updated
17 Nov 2015
Results posted
No
Data monitoring committee
Yes

Publications

  • Hogh Petersen H, Chen X, Pietersen A, Svendsen JH, Haunso S. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling. Circulation. 1999 Jan 19;99(2):319-25. doi: 10.1161/01.cir.99.2.319.

    PubMed 9892601
  • Sanchez JE, Kay GN, Benser ME, Hall JA, Walcott GP, Smith WM, Ideker RE. Identification of transmural necrosis along a linear catheter ablation lesion during atrial fibrillation and sinus rhythm. J Interv Card Electrophysiol. 2003 Feb;8(1):9-17. doi: 10.1023/a:1022315308803.

    PubMed 12652172

Questions about this trial

What is this clinical trial studying?

An observational study of Atrial Flutter and Arrhythmia, run by Emory University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Nov 2015. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Total bipolar electrogram amplitude using tip to ring and pin to pin configurations (time frame: Acute, averaged one hour during ablation. Measured postoperatively.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT02089672, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Nov 2015.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.