Complex Abdominal Aortic AneurysmNCT02089607
CAAAs, TAAAs, Aortic Arch Aneurysms or Dissections With Fenestrated/Branched Stent Graft
A study testing CAAA and TAAA Arm and Aortic Arch Aneurysm Arm in people with Complex Abdominal Aortic Aneurysm and Thoracoabdominal Aortic Aneurysm, run by Gustavo S Oderich at 3 sites in United States.
Trial summary
The purpose of this study is to gather safety and effectiveness of the Zenith t-Branch and customized physician-specified stent-graft with a combination of fenestrations and/or branches to repair aortic aneurysm. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Complex Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm, Aortic Arch Aneurysm
- What is being tested?
- CAAA and TAAA Arm and Aortic Arch Aneurysm Arm
- Type of treatment
- Injection or infusion, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 760 participants
- Where
- 3 sitesUnited States
- Study dates
- Mar 2014to May 2032
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
General Inclusion Criteria:
- Thoracoabdominal aortic aneurysm with a diameter ≥ 5.5 cm or 2 times the normal aortic diameter.
- Aneurysm with a history of growth ≥ 0.5 cm per year.
- Saccular aneurysms deemed at significant risk for rupture based upon physician interpretation.
- Presence of concomitant thoracoabdominal and aortic arch aneurysm meeting one of the above-mentioned criteria.
- Presence of thoracoabdominal aortic aneurysm meeting one of the above-mentioned criteria with unilateral or bilateral common iliac artery aneurysm with diameter ≥ 3.0-cm or saccular morphology with no suitable landing zone proximal to iliac bifurcation.
General Exclusion Criteria:
- Less than 18 years of age
- Unwilling to comply with the follow-up schedule
- Inability or refusal to give informed consent by the patient or a legally authorized representative
- Pregnant or breastfeeding
- Life expectancy < 2 years
- Prior open surgical or interventional procedure within 30 days of the anticipated date of the fenestrated-branched procedure, with the exception of planned staged procedures to provide access for repair (e.g. staged iliac conduit, cervical debranching, elephant trunk repair), to facilitate the procedure by allowing open revascularization of a target artery not amenable to revascularization with the investigational device, such as an internal iliac artery, subclavian artery or visceral artery with early bifurcation, tortuosity or occlusive disease preventing successful placement of alignment side stents.
- Participation in another investigational clinical or device trial, with the exception of participation in another investigational endovascular stent-graft protocol, percutaneous aortic valve protocol, or concomitant clinical trials designed to evaluate medical therapy strategies to reduce perioperative risk during fenestrated-branched endovascular repair, including risks of renal dysfunction, contrast-induced nephropathy, neurologic, spinal cord or cardiac complications, and/or use of advanced imaging to reduce radiation exposure during implantation of these devices. Participation in investigational device trials not encompassed by the IDE protocol should be performed remotely from the fenestrated procedure (> 30 days). Examples include remote (>30 days) participation in a thoracic, abdominal or iliac branch device trial, or participation in a percutaneous aortic valve trial. Participation in medical therapy trial or advanced imaging trial designed to improve peri-operative outcomes or to reduce radiation exposure of fenestrated-branched endografts may be concurrent with the IDE study. Examples include therapy directed to reduce rates of spinal cord injury, stroke and contrast-induced nephropathy associated with implantation of fenestrated-branched stent-grafts or advanced imaging trials designed to reduce radiation exposure during repair.
- Patients with ruptured aortic aneurysms requiring urgent or emergent repair, with the exception of patients with contained, stable ruptures with anatomy suitable for an off-the-shelf design.
Medical Exclusion Criteria:
- Known sensitivities or allergies to stainless steel, nitinol, polyester, solder (tin, silver), polypropylene, PTFE, urethane or gold
- History of anaphylactic reaction to contrast material that cannot be adequately pre-medicated
- Leaking or ruptured aneurysm associated with hypotension
- Uncorrectable coagulopathy
- Mycotic aneurysm or patients with evidence of active systemic infection.
- History of connective tissue disorder (e.g vascular Ehlers Danlos, Marfans syndrome), with the exception of those patients who had prior open surgical aortic replacement, where a surgical graft would serve as landing zone for the investigational stent-graft, those who are deemed prohibitive risk for open surgical repair or connective tissue disorders with no effect of vascular system (e.g non-vascular forms of Ehlers Danlos).
- Body habitus that would inhibit X-ray visualization of the aorta and its branches.
Anatomical Exclusion Criteria:
- Inadequate femoral or iliac access compatible with the required delivery systems.
- Inability to perform a temporary or permanent open surgical or endovascular iliac conduit for patients with inadequate femoral/iliac access.
- Absence of a non-aneurysmal aortic segment in the distal thoracic aorta above the diaphragmatic hiatus with: a. A diameter measured outer wall to outer wall of no greater than 42mm and no less than 21 mm; b. Parallel aortic wall with <20% diameter change and without significant calcification and/or thrombus in the selected area of seal zone
- Visceral vessel anatomy not compatible with Zenith t-Branch or patient-specific stent-graft due to excessive occlusive disease or small size not amenable to stent graft placement
- Unsuitable distal iliac artery fixation site and anatomy for iliac limb extension or iliac branch device: a. Common iliac artery fixation site diameter, measured outer wall to outer wall on a sectional image (CT) <8.0 mm with inability to perform open surgical conduit ; b. Iliac artery diameter, measured outer wall to outer wall on a sectional image (CT) >20 mm at distal fixation site, with inability to perform open internal iliac artery revascularization or iliac branch stent graft ; c. Non-aneurysmal external liac artery distal fixation site <10 mm in length ; d. Non-aneurysmal internal iliac artery main trunk or branch segment with length <10mm or with inner wall diameter <4 or >14mm; e. Unsuitable anatomy due to inability to preserve at least one hypogastric artery
Additional anatomical inclusion criteria for aortic arch devices:
- Proximal aortic fixation zone: a. Native aorta or surgical graft; b. Diameter: 20-42mm; c. Proximal neck length ≥ 20mm; d. Ascending aortic length ≥50mm; e. Must occur distal to coronary arteries and any coronary artery bypass grafts that are considered patent and necessary for proper cardiac perfusion
- Distal aortic fixation zone:; a. Native aorta or surgical graft; b. Diameter: 20-42mm; c. Distal neck length ≥20mm
- Supra-aortic trunk (brachiocephalic) vessels: a. Although the prosthesis will typically have two branches, modifications to the design will allow for a single branch, three branches or combination of branch and scallop if a customized version is required. Thus, it is generally planned that at least one extra-anatomic bypass graft will be done in conjunction (or in a staged fashion) with the procedure, unless three branches are planned. The two vessels incorporated into the endograft repair would most commonly be the innominate artery and left common carotid artery. However, the innominate artery may be coupled with the left subclavian artery in the setting of a bovine arch whereby the flow to the left carotid would come from a left subclavian to carotid bypass. Similarly, the left carotid and subclavian artery may be branched, or simply one vessel branched should specific anatomic limitations exist. In such a situation, multiple extra-anatomic bypasses may be necessary. A design with a single subclavian retrograde branch and double scallop to the left carotid artery may be used to extent the landing zone to Zone 1. Finally, a design with two antegrade inner branches for the innominate and left common carotid, and one retrograde inner branch for the left subclavian artery may be used in select cases. Thus the inclusion criteria are defined for each artery, yet any combination of arteries may be used for a repair: Innominate artery (Native vessel or surgical graft, Diameter: 8-22mm, Length of sealing zone ≥10mm, Acceptable tortuosity); Left (or right) common carotid artery (Native vessel or surgical graft, Diameter 6-16mm, Length of sealing zone ≥10mm, Acceptable tortuosity); Left (or right) common carotid artery (Native vessel or surgical graft, Diameter: 5-20mm, Length of sealing zone ≥10mm, Acceptable tortuosity).
- In the setting of an aortic dissection the following criteria must exist: a. Access into the true lumen from the groin and at least one supra-aortic trunk vessel; b. A sealing zone in the target aorta (or surgical graft) that is proximal to the primary dissection, such that a stent-graft would be anticipated to seal off the dissection lumen; c. A sealing zone in the target supra-aortic trunk vessels that is distal to the dissection, anticipated to seal off the dissection lumen, or surgically created; d. A true lumen size large enough to deploy the device and still gain access into the target branches
- In the setting of more distal disease: a. The repair may be coupled with a thoracoabdominal branched device, infrarenal device, and/or internal iliac branch device.
- Iliac anatomy must allow for the delivery of the arch branch device which is loaded within a 20F-24F sheath. Thus the iliac requirements are no different than the standard thoracic protocol. Conduits to the iliac vessels or aorta may be used if deemed necessary.
Trial locations and contacts
3 sites in 1 country. Contact the study team or a site near you to ask about taking part.
United States3 sites, 1 recruiting
- Recruiting
Baylor College of Medicine
Houston, Texas, 77030
Andrea C Martinez, BS, 713-798-6835, andrea.martinez@bcm.edu
Ying Huang, MD, PhD, 832-355-9034, Ying.Huang@bcm.edu
- Active, not recruiting
University of Texas Health Science Center at Houston
Houston, Texas, 77089
- Active, not recruiting
Mayo Clinic
Rochester, Minnesota, 55905
About this study
Official title: Clinical Outcomes and Quality of Life Measures in Patients Treated for Complex Abdominal, Thoracoabdominal and Aortic Arch Aneurysms or Dissections With Fenestrated and Branched Stent Grafts
The purpose of this study is to gather safety and effectiveness of the Zenith t-Branch and customized physician-specified stent-graft with a combination of fenestrations and/or branches to repair aortic aneurysm.
Read the detailed description
This is a traditional device feasibility study intended to generate preliminary safety and efficacy information that may be used to plan an appropriate future study, or to inform further product development.
Subjects will have been diagnosed with a bulge or aneurysm in their aortic arch and or abdominal aorta, which is the blood vessel in the abdomen (belly) that supplies blood to most of the lower body including major organs and the legs.
The Zenith t-Branch and physician-specified fenestrated and branched endovascular graft is a tubular graft made of polyester fabric sewn to stainless steel stents that keep the graft open. As an aneurysm expands, the walls become weak and may rupture, causing a major loss of blood with a high risk of death and other serious complications. To avoid this risk the aneurysm will be repaired by putting a graft inside the aneurysm. The graft will be inserted through arteries in the groin (called endovascular repair). This procedure uses catheters that go inside the blood vessel to place a stent-graft above and below the aneurysm.
The graft includes 1 to 5 small holes (fenestrations) or cuffs (side branches). These small holes or branches are the investigational part of this research study. The arteries to the liver, intestine, and kidneys will have a stent (small tubular stainless steel structures) to help keep the arteries open and aligned with the fenestrations or branches. The Zenith t-Branch and physician-specified fenestrated and branched endovascular graft will be referred to as the Zenith Fenestrated-Branched System.
- Conditions
- Complex Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm, Aortic Arch Aneurysm, Aortic Arch Dissection
- Being tested
- CAAA and TAAA Arm, Aortic Arch Aneurysm Arm
- Keywords
- aneurysm, aortic aneurysm
- Medical subject headings
- Aortic Aneurysm, Thoracoabdominal, Aneurysm, Aortic Arch, Dissection, Thoracic Aorta, Aneurysm, Aortic Aneurysm
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
CAAA and TAAA ArmDevice
Also called Endovascular stent, Stent-graft
The Zenith Fenestrated-Branched System is a tubular graft made of polyester fabric sewn to stainless steel stents that keep the graft open. The graft will be inserted through arteries in the leg (called endovascular repair). This procedure uses catheters that go inside the blood vessel to place a stent graft above and below the aneurysm. The graft includes 1 to 5 small holes (fenestrations) or cuffs (side branches). One or more than one of the study devices including the Zenith® Fenestrated AAA Endovascular Graft, Zenith® t-Branch Endovascular Graft, Patient-Specific Thoracoabdominal Graft, Patient-Specific Distal Bifurcated Component, and Zenith® Branch Endovascular Graft-Iliac Bifurcation will be implanted. The arteries to the liver, intestine, and kidneys will have a stent (small tubular stainless steel structures) to help keep the arteries open and aligned with the fenestrations or branches.
Aortic Arch Aneurysm ArmDevice
The Zenith® Arch Branch Endovascular Graft includes the main aortic arch portion and one to three cuffs (side branches) that allow the graft to be located in the aortic arch. The number of cuffs is decided based on the anatomy of your aneurysm. The arteries in the aortic arch are the innominate artery (Zone 0), left common carotid artery (Zone 1) and the left subclavian artery (Zone 2). These arteries supply the right arm and right side of the brain, the left side of the brain and the left arm, respectively. The main aortic endovascular graft will be connected into the innominate artery, left common carotid artery and left subclavian artery using additional stents into the branch vessels.
| Study group | Role | What they receive |
|---|---|---|
| Complex Abdominal (CAAA) and Thoracoabdominal Aortic Aneurysm (TAAA) Arm | Experimental | The CAAA and TAAA study arm will include 700 patients treated by endovascular aortic repair of CAAAs and TAAAs (Extent I to IV) using either an off-the-shelf Zenith t-Branch or patient-specific stent-graft with a combination of fenestrations and/or branches, with or without concomitant unilateral or bilateral iliac artery aneurysms treated by iliac branch devices. The graft includes 1 to 5 small holes (fenestrations) or cuffs (side branches). These small holes or branches are the investigational part of this research study. The arteries to the liver, intestine, and kidneys will have a stent (small tubular stainless steel structures) to help keep the arteries open and aligned with the fenestrations or branches. Receives: Device: CAAA and TAAA Arm |
| Aortic Arch Aneurysm Arm | Experimental | Aortic Arch study arm will include 60 patients with aortic arch aneurysms treated by patient-specific stent-grafts with one to three inner branches or a scallop.
The study will include patients with CAAAs, TAAAs and/or aortic arch aneurysms due to degenerative aneurysms or chronic aortic dissections. The stent-graft design for this study will be individually selected based on anatomy at the discretion of the principal investigator. Receives: Device: Aortic Arch Aneurysm Arm |
What is being measured
The primary outcome is the main question the study is designed to answer.
Number of subjects who have died at 30 days post treatment
Deaths 30 days after treatment
Measured: 30 days post treatment
Number of subjects who experience a Major Adverse Event at 30 days post treatment
A Major Adverse Event includes any of the following: bowel ischemia, myocardial infarction (heart attack), paraplegia, renal failure, respiratory failure, stroke, or blood loss greater than 1000 ml.
Measured: 30 days post treatment
Secondary outcomes (2)
Percentage of subjects who achieve treatment success
Treatment success is defined by a composite endpoint, which includes all the following criteria: 1) technical success, defined as successful delivery and deployment of the custom-made endovascular graft with preservation of those branch vessels intended to be preserved; 2) freedom from type I or III endoleak; 3) freedom from stent-graft migration; 4) freedom from aneurysm enlargement >5 mm; 5) freedom from aneurysm rupture or conversion to open repair.
Measured: 12 months post treatment
Mean Quality of Life Measure at Various Time Points
Subjects complete the Short-Form General Health Survey (SF-36) form which consists of an 11 question survey that is divided into 2 parts: physical and emotional. The scale scores range from 0 to 100, with (0 = worst imaginable, 100 = best imaginable).
Measured: Pre-procedure, 30 days, 6 months, 1 year, 2 years, 3 years, 4 years, 5 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted18 Mar 2014 (estimated)
- Study startMar 2014
- Primary completionMar 2028 (estimated)
- Study completionMay 2032 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (104)Papers the sponsor has linked to this study.
- Other trials for Complex Abdominal Aortic AneurysmStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 760 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Gustavo S Oderich
- Sponsor type
- University, hospital or other
- Collaborators
- William Cook Australia
- Responsible party
- Sponsor-investigator, Gustavo S Oderich, Baylor College of Medicine
- Investigators
- Gustavo S. Oderich, MD, Principal investigator, Baylor College of Medicine
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02089607
- Sponsor's protocol ID
- H-56531
- Status last verified
- Aug 2026
- First submitted
- 14 Mar 2014
- Last updated
- 27 Aug 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Publications
Rhee R, Oderich G, Hertault A, Tenorio E, Shih M, Honari S, Jacob T, Haulon S. Multicenter experience in translumbar type II endoleak treatment in the hybrid room with needle trajectory planning and fusion guidance. J Vasc Surg. 2020 Sep;72(3):1043-1049. doi: 10.1016/j.jvs.2019.10.076. Epub 2019 Dec 25.
PubMed 31882316Lima GB, Huang Y, Ruiter Kanamori L, Tenorio ER, Schmid BP, Maximus S, Saqib N, Macedo TA, Mendes BC, Oderich GS. Comparison of Bare Metal vs Covered Proximal Stent Fixation During Fenestrated Endovascular Aortic Repair of Complex Abdominal Aortic Aneurysms. J Endovasc Ther. 2025 Nov 10:15266028251388749. doi: 10.1177/15266028251388749. Online ahead of print.
PubMed 41211656Finnesgard EJ, Simons JP, Beck AW, Eagleton MJ, Farber MA, Gasper WJ, Lee WA, Oderich GS, Schneider DB, Sweet MP, Timaran CH, Schanzer A; United States Aortic Research Consortium. Residual aneurysm behavior is associated with aortic outcomes after fenestrated and branched endovascular aortic repair. J Vasc Surg. 2026 Jul;84(1):4-12.e2. doi: 10.1016/j.jvs.2026.02.021. Epub 2026 Feb 24.
PubMed 41748036Baghbani A, Savadi S, Sulzer TAL, Tenorio ER, Mesnard T, Vacirca A, Mendes BC, Saqib NU, Maximus S, Huang Y, Oderich GS. Familial History of Aortic Disease Does Not Affect Outcomes of Fenestrated-Branched Endovascular Aortic Repair in Patients With Complex Aortic Aneurysms. J Endovasc Ther. 2026 Feb 9:15266028261417156. doi: 10.1177/15266028261417156. Online ahead of print.
PubMed 41664301Ruiter Kanamori L, Dias-Neto M, Porras-Colon J, Lima GB, Huang Y, Figueroa A, Han SM, Mendes BC, Macedo TA, Saqib N, Maximus S, Timaran CH, Oderich GS. Treatment and outcomes of type IIIb endoleaks affecting the main fenestrated-branched aortic stent graft component among patients treated for complex abdominal and thoracoabdominal aortic aneurysms. J Vasc Surg. 2025 Dec;82(6):1935-1944. doi: 10.1016/j.jvs.2025.06.112. Epub 2025 Jul 17.
PubMed 40683396Schmid BP, Kanamori LR, Abdelhalim MA, Vanmaele A, Lima GB, Babocs D, Nair HR, Huang Y, Modarai B, Oderich GS. Early and late outcomes of patient-specific endografts with retrograde outer branches for complex aortic aneurysms involving cranially oriented target vessels. J Vasc Surg Cases Innov Tech. 2025 Nov 7;12(1):102004. doi: 10.1016/j.jvscit.2025.102004. eCollection 2026 Feb.
PubMed 41625970Sulzer TAL, Macedo TA, Mesnard T, Tenorio ER, Baumgardt Barbosa Lima G, Hatz H, Hesley GK, Lekah A, Tallarita T, Huang Y, Mendes BC, Oderich GS. Prospective Assessment of Changes in Target Vessel Peak Systolic Velocity Measurements After Fenestrated-Branched Endovascular Aortic Repair. J Endovasc Ther. 2025 Sep 28:15266028251368250. doi: 10.1177/15266028251368250. Online ahead of print.
PubMed 41015897Huang Y, Colglazier J, Pochettino A, Kalra M, Bower TC, Greason KL, Mendes BC, Tenorio ER, Gloviczki P, Harmsen WS, Oderich GS. Treatment Trends and Outcomes of Endovascular versus Open Thoracoabdominal Aortic Aneurysm Repair - A Single-center Comparative Cohort Study. Ann Surg. 2025 Jul 25. doi: 10.1097/SLA.0000000000006848. Online ahead of print.
PubMed 40720611Sickels AD, Novak Z, Schanzer A, Farber MA, Sweet MP, Oderich GS, Schneider DB, Eagleton MJ, Timaran C, Gasper WJ, Lee WA, Beck AW. Evolving practices of spinal drain use for branch/fenestrated endovascular aortic repair patients in the United States Aortic Research Consortium. J Vasc Surg. 2025 Jun;81(6):1266-1277.e1. doi: 10.1016/j.jvs.2025.01.216. Epub 2025 Feb 4.
PubMed 39914760Finnesgard EJ, Jones DW, Beck AW, Eagleton MJ, Farber MA, Gasper WJ, Lee WA, Oderich GS, Schneider DB, Sweet MP, Timaran CH, Schanzer A; United States Aortic Research Consortium. Trends and outcomes over time with fenestrated and branched endovascular aortic repair in the United States Aortic Research Consortium. J Vasc Surg. 2025 Jun;81(6):1235-1243. doi: 10.1016/j.jvs.2025.01.213. Epub 2025 Feb 4.
PubMed 39914755Babocs D, Kanamori LR, Schmid BP, Tenorio E, Maximus S, Mendes BC, Macedo TA, Huang Y, Oderich GS. Increasing clinical experience and changes in practice protocols improved outcomes of fenestrated branched endovascular repair of complex aortic aneurysms. J Vasc Surg. 2025 Oct;82(4):1156-1167.e2. doi: 10.1016/j.jvs.2025.05.031. Epub 2025 May 21.
PubMed 40409435Ribe L, Ruiter Kanamori L, Schmid BP, Macedo TA, Mendes BC, Maximus S, Huang Y, Nasser F, Oderich GS. Outcomes of fenestrated-branched endovascular aortic repair of thoracoabdominal aortic aneurysms in patients with heritable thoracic aortic diseases. JTCVS Tech. 2025 May 9;32:10-19. doi: 10.1016/j.xjtc.2025.04.025. eCollection 2025 Aug.
PubMed 40814684Vanmaele A, Ruiter Kanamori L, Vacirca A, Babocs D, Mesnard T, Maximus S, Huang Y, Feng CMJ, Huynh J, Oderich GS. Direct absorbed and equivalent dose of radiation to the eyes in patients and operators during fenestrated and branched endovascular aortic repair. J Vasc Surg. 2025 Aug;82(2):646-654. doi: 10.1016/j.jvs.2025.04.033. Epub 2025 Apr 28.
PubMed 40306594Ruiter Kanamori L, Vacirca A, Babocs D, Tenorio ER, Lima GBB, Mendes BC, Huang Y, Maximus S, Estrera A, Oderich GS. Implementation of a Comprehensive Endovascular Aortic Programme and Maintenance of Clinical Excellence during Fenestrated Branched Endovascular Aortic Repair in Two Centres. Eur J Vasc Endovasc Surg. 2025 Mar;69(3):407-414. doi: 10.1016/j.ejvs.2024.11.014. Epub 2024 Nov 19.
PubMed 39571886Fan EY, Schanzer A, Beck AW, Eagleton MJ, Farber MA, Gasper WJ, Lee WA, Oderich GS, Parodi FE, Schneider DB, Sweet MP, Timaran CH, Simons JP; US Aortic Research Consortium. Practice patterns of antiplatelet and anticoagulant therapy after fenestrated/branched endovascular aortic repair. J Vasc Surg. 2024 Oct;80(4):968-978.e3. doi: 10.1016/j.jvs.2024.05.041. Epub 2024 May 23.
PubMed 38796031
Study at a glance
From the registry record, last updated by the sponsor on 27 Aug 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Outcomes and Quality of Life Measures in Patients Treated for Complex Abdominal, Thoracoabdominal and Aortic Arch Aneurysms or Dissections With Fenestrated and Branched Stent Grafts
- ClinicalTrials.gov ID
- NCT02089607
- Acronym / sponsor ID
- H-56531
- Conditions
- Complex Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm, Aortic Arch Aneurysm, Aortic Arch Dissection
- Keywords
- aneurysm, aortic aneurysm
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 760 participants (estimated)
- Lead sponsor
- Gustavo S OderichUniversity, hospital or other
- Collaborators
- William Cook Australia
- Study start
- Mar 2014 (actual)
- Primary completion
- Mar 2028 (estimated)
- Study completion
- May 2032 (estimated)
- First posted
- 18 Mar 2014 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to gather safety and effectiveness of the Zenith t-Branch and customized physician-specified stent-graft with a combination of fenestrations and/or branches to repair aortic aneurysm.
Detailed description
This is a traditional device feasibility study intended to generate preliminary safety and efficacy information that may be used to plan an appropriate future study, or to inform further product development.
Subjects will have been diagnosed with a bulge or aneurysm in their aortic arch and or abdominal aorta, which is the blood vessel in the abdomen (belly) that supplies blood to most of the lower body including major organs and the legs.
The Zenith t-Branch and physician-specified fenestrated and branched endovascular graft is a tubular graft made of polyester fabric sewn to stainless steel stents that keep the graft open. As an aneurysm expands, the walls become weak and may rupture, causing a major loss of blood with a high risk of death and other serious complications. To avoid this risk the aneurysm will be repaired by putting a graft inside the aneurysm. The graft will be inserted through arteries in the groin (called endovascular repair). This procedure uses catheters that go inside the blood vessel to place a stent-graft above and below the aneurysm.
The graft includes 1 to 5 small holes (fenestrations) or cuffs (side branches). These small holes or branches are the investigational part of this research study. The arteries to the liver, intestine, and kidneys will have a stent (small tubular stainless steel structures) to help keep the arteries open and aligned with the fenestrations or branches. The Zenith t-Branch and physician-specified fenestrated and branched endovascular graft will be referred to as the Zenith Fenestrated-Branched System.
Study design
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Complex Abdominal (CAAA) and Thoracoabdominal Aortic Aneurysm (TAAA) Arm | Experimental | Device: CAAA and TAAA ArmThe CAAA and TAAA study arm will include 700 patients treated by endovascular aortic repair of CAAAs and TAAAs (Extent I to IV) using either an off-the-shelf Zenith t-Branch or patient-specific stent-graft with a combination of fenestrations and/or branches, with or without concomitant unilateral or bilateral iliac artery aneurysms treated by iliac branch devices. The graft includes 1 to 5 small holes (fenestrations) or cuffs (side branches). These small holes or branches are the investigational part of this research study. The arteries to the liver, intestine, and kidneys will have a stent (small tubular stainless steel structures) to help keep the arteries open and aligned with the fenestrations or branches. |
| Aortic Arch Aneurysm Arm | Experimental | Device: Aortic Arch Aneurysm ArmAortic Arch study arm will include 60 patients with aortic arch aneurysms treated by patient-specific stent-grafts with one to three inner branches or a scallop. The study will include patients with CAAAs, TAAAs and/or aortic arch aneurysms due to degenerative aneurysms or chronic aortic dissections. The stent-graft design for this study will be individually selected based on anatomy at the discretion of the principal investigator. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| CAAA and TAAA ArmAlso: Endovascular stent, Stent-graftThe Zenith Fenestrated-Branched System is a tubular graft made of polyester fabric sewn to stainless steel stents that keep the graft open. The graft will be inserted through arteries in the leg (called endovascular repair). This procedure uses catheters that go inside the blood vessel to place a stent graft above and below the aneurysm. The graft includes 1 to 5 small holes (fenestrations) or cuffs (side branches). One or more than one of the study devices including the Zenith® Fenestrated AAA Endovascular Graft, Zenith® t-Branch Endovascular Graft, Patient-Specific Thoracoabdominal Graft, Patient-Specific Distal Bifurcated Component, and Zenith® Branch Endovascular Graft-Iliac Bifurcation will be implanted. The arteries to the liver, intestine, and kidneys will have a stent (small tubular stainless steel structures) to help keep the arteries open and aligned with the fenestrations or branches. | Device | Complex Abdominal (CAAA) and Thoracoabdominal Aortic Aneurysm (TAAA) Arm |
| Aortic Arch Aneurysm ArmThe Zenith® Arch Branch Endovascular Graft includes the main aortic arch portion and one to three cuffs (side branches) that allow the graft to be located in the aortic arch. The number of cuffs is decided based on the anatomy of your aneurysm. The arteries in the aortic arch are the innominate artery (Zone 0), left common carotid artery (Zone 1) and the left subclavian artery (Zone 2). These arteries supply the right arm and right side of the brain, the left side of the brain and the left arm, respectively. The main aortic endovascular graft will be connected into the innominate artery, left common carotid artery and left subclavian artery using additional stents into the branch vessels. | Device | Aortic Arch Aneurysm Arm |
Primary outcome
Number of subjects who have died at 30 days post treatment
Time frame: 30 days post treatment
Deaths 30 days after treatment
Number of subjects who experience a Major Adverse Event at 30 days post treatment
Time frame: 30 days post treatment
A Major Adverse Event includes any of the following: bowel ischemia, myocardial infarction (heart attack), paraplegia, renal failure, respiratory failure, stroke, or blood loss greater than 1000 ml.
2 secondary outcomes
Percentage of subjects who achieve treatment success
Time frame: 12 months post treatment
Mean Quality of Life Measure at Various Time Points
Time frame: Pre-procedure, 30 days, 6 months, 1 year, 2 years, 3 years, 4 years, 5 years
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 Aug 2026.
- Results publication: PubMed 31882316Rhee R, Oderich G, Hertault A, Tenorio E, Shih M, Honari S, Jacob T, Haulon S. Multicenter experience in translumbar type II endoleak treatment in the hybrid room with needle trajectory planning and fusion guidance. J Vasc Surg. 2020 Sep;72(3):1043-1049. doi: 10.1016/j.jvs.2019.10.076. Epub 2019 Dec 25.
- Results publication: PubMed 41211656Lima GB, Huang Y, Ruiter Kanamori L, Tenorio ER, Schmid BP, Maximus S, Saqib N, Macedo TA, Mendes BC, Oderich GS. Comparison of Bare Metal vs Covered Proximal Stent Fixation During Fenestrated Endovascular Aortic Repair of Complex Abdominal Aortic Aneurysms. J Endovasc Ther. 2025 Nov 10:15266028251388749. doi: 10.1177/15266028251388749. Online ahead of print.
- Results publication: PubMed 41748036Finnesgard EJ, Simons JP, Beck AW, Eagleton MJ, Farber MA, Gasper WJ, Lee WA, Oderich GS, Schneider DB, Sweet MP, Timaran CH, Schanzer A; United States Aortic Research Consortium. Residual aneurysm behavior is associated with aortic outcomes after fenestrated and branched endovascular aortic repair. J Vasc Surg. 2026 Jul;84(1):4-12.e2. doi: 10.1016/j.jvs.2026.02.021. Epub 2026 Feb 24.
- Results publication: PubMed 41664301Baghbani A, Savadi S, Sulzer TAL, Tenorio ER, Mesnard T, Vacirca A, Mendes BC, Saqib NU, Maximus S, Huang Y, Oderich GS. Familial History of Aortic Disease Does Not Affect Outcomes of Fenestrated-Branched Endovascular Aortic Repair in Patients With Complex Aortic Aneurysms. J Endovasc Ther. 2026 Feb 9:15266028261417156. doi: 10.1177/15266028261417156. Online ahead of print.
- Results publication: PubMed 40683396Ruiter Kanamori L, Dias-Neto M, Porras-Colon J, Lima GB, Huang Y, Figueroa A, Han SM, Mendes BC, Macedo TA, Saqib N, Maximus S, Timaran CH, Oderich GS. Treatment and outcomes of type IIIb endoleaks affecting the main fenestrated-branched aortic stent graft component among patients treated for complex abdominal and thoracoabdominal aortic aneurysms. J Vasc Surg. 2025 Dec;82(6):1935-1944. doi: 10.1016/j.jvs.2025.06.112. Epub 2025 Jul 17.
- Results publication: PubMed 41625970Schmid BP, Kanamori LR, Abdelhalim MA, Vanmaele A, Lima GB, Babocs D, Nair HR, Huang Y, Modarai B, Oderich GS. Early and late outcomes of patient-specific endografts with retrograde outer branches for complex aortic aneurysms involving cranially oriented target vessels. J Vasc Surg Cases Innov Tech. 2025 Nov 7;12(1):102004. doi: 10.1016/j.jvscit.2025.102004. eCollection 2026 Feb.
- Results publication: PubMed 41015897Sulzer TAL, Macedo TA, Mesnard T, Tenorio ER, Baumgardt Barbosa Lima G, Hatz H, Hesley GK, Lekah A, Tallarita T, Huang Y, Mendes BC, Oderich GS. Prospective Assessment of Changes in Target Vessel Peak Systolic Velocity Measurements After Fenestrated-Branched Endovascular Aortic Repair. J Endovasc Ther. 2025 Sep 28:15266028251368250. doi: 10.1177/15266028251368250. Online ahead of print.
- Results publication: PubMed 40720611Huang Y, Colglazier J, Pochettino A, Kalra M, Bower TC, Greason KL, Mendes BC, Tenorio ER, Gloviczki P, Harmsen WS, Oderich GS. Treatment Trends and Outcomes of Endovascular versus Open Thoracoabdominal Aortic Aneurysm Repair - A Single-center Comparative Cohort Study. Ann Surg. 2025 Jul 25. doi: 10.1097/SLA.0000000000006848. Online ahead of print.
- Results publication: PubMed 39914760Sickels AD, Novak Z, Schanzer A, Farber MA, Sweet MP, Oderich GS, Schneider DB, Eagleton MJ, Timaran C, Gasper WJ, Lee WA, Beck AW. Evolving practices of spinal drain use for branch/fenestrated endovascular aortic repair patients in the United States Aortic Research Consortium. J Vasc Surg. 2025 Jun;81(6):1266-1277.e1. doi: 10.1016/j.jvs.2025.01.216. Epub 2025 Feb 4.
- Results publication: PubMed 39914755Finnesgard EJ, Jones DW, Beck AW, Eagleton MJ, Farber MA, Gasper WJ, Lee WA, Oderich GS, Schneider DB, Sweet MP, Timaran CH, Schanzer A; United States Aortic Research Consortium. Trends and outcomes over time with fenestrated and branched endovascular aortic repair in the United States Aortic Research Consortium. J Vasc Surg. 2025 Jun;81(6):1235-1243. doi: 10.1016/j.jvs.2025.01.213. Epub 2025 Feb 4.
- Results publication: PubMed 40409435Babocs D, Kanamori LR, Schmid BP, Tenorio E, Maximus S, Mendes BC, Macedo TA, Huang Y, Oderich GS. Increasing clinical experience and changes in practice protocols improved outcomes of fenestrated branched endovascular repair of complex aortic aneurysms. J Vasc Surg. 2025 Oct;82(4):1156-1167.e2. doi: 10.1016/j.jvs.2025.05.031. Epub 2025 May 21.
- Results publication: PubMed 40814684Ribe L, Ruiter Kanamori L, Schmid BP, Macedo TA, Mendes BC, Maximus S, Huang Y, Nasser F, Oderich GS. Outcomes of fenestrated-branched endovascular aortic repair of thoracoabdominal aortic aneurysms in patients with heritable thoracic aortic diseases. JTCVS Tech. 2025 May 9;32:10-19. doi: 10.1016/j.xjtc.2025.04.025. eCollection 2025 Aug.
- Individual participant dataSharing planned: No
Related trials for Complex Abdominal Aortic Aneurysm
Not yet recruitingObservational study
Real-World Data Collection of GORE Devices Used In the Endovascular Treatment of Aortic Aneurysms Which Incorporate Visceral Arteries.
Complex Aortic Aneurysms, Thoracoabdominal Aneurysm
Recruiting
Clinical Trial of BAO-G Technique in Complex Aortic Aneurysm Endovascular Repair (BAO-G-02)
Thoracoabdominal Aortic Aneurysm, Endovascular Repair
RecruitingObservational study
Patient-Reported Quality of Life After Open Surgery for Complex Abdominal Aortic Aneurysms: A Prospective Study
Complex Abdominal Aortic Aneurysms
RecruitingObservational study
European Aortic Data Collection Project
Complex Abdominal Aortic Aneurysm, Thoracoabdominal Aortic Aneurysm
Enrolling by invitation
Clinical Outcomes and Radiation Safety After Endovascular Repair of Complex AAAs Using Fenestrated- Branched Devices
Aortic Aneurysm, Abdominal, Thoracic Aneurysm
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Gustavo S. Oderich, MD principal investigator
Baylor College of Medicine
3 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing CAAA and TAAA Arm and Aortic Arch Aneurysm Arm in people with Complex Abdominal Aortic Aneurysm and Thoracoabdominal Aortic Aneurysm, run by Gustavo S Oderich at 3 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 27 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 3 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Andrea C Martinez, BS (713-798-6835, andrea.martinez@bcm.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Number of subjects who have died at 30 days post treatment (time frame: 30 days post treatment). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02089607, which also lists 104 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Aug 2026.