RCT of Mesh Versus Jet Nebulizers on Clinical Outcomes During Mechanical Ventilation in the Intensive Care Unit

A study testing Vibrating Mesh Nebulizer Arm and Jet Nebulizer Arm in people with Respiratory Insufficiency, run by Rush University Medical Center at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Aerosol delivery during mechanical ventilation has long been a long debated topic. As evidence-based knowledge about the delivery of aerosol to the lungs of mechanically ventilated patients increases, one piece of the puzzle has remained unexplored; measurement of clinically relevant outcomes. Read more about this study

Who is it for?
Ages 1 year and older
Conditions the study is for
Respiratory Insufficiency
What is being tested?
Vibrating Mesh Nebulizer Arm and Jet Nebulizer Arm
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
120 participants
Where
1 siteUnited States
Study dates
Sep 2013to Oct 2014
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 1 year and older
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Age > 1 y/o
  • Intubated with endotracheal tube (ETT) and on mechanical ventilation
  • Patient in all intensive care units at Rush University Medical Center
  • Physician order for aerosolized breathing treatment in medical record

Who cannot join

  • Age < 1 y/o
  • Diaphragmatic paralysis
  • Paraplegic or high spinal cord injury
  • Brain death

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Rush University Medical Center

    Chicago, Illinois, 60612

Other trials in United States

About this study

Official title: Randomized Controlled Trial of Mesh Versus Jet Nebulizers on Clinical Outcomes During Mechanical Ventilation in the Intensive Care Unit

Aerosol delivery during mechanical ventilation has long been a long debated topic. As evidence-based knowledge about the delivery of aerosol to the lungs of mechanically ventilated patients increases, one piece of the puzzle has remained unexplored; measurement of clinically relevant outcomes. The primary aim of this research is to compare clinical outcomes (ventilator-associated events (VAEs), length of stay (LOS) in intensive care unit (ICU), and total days on mechanical ventilation) when using a traditional jet nebulizer versus a newer generation vibrating mesh nebulizer during mechanical ventilation. The secondary aim of this research is to identify source of bacteria by obtaining cultures of each nebulizer and ventilator circuit and plating them for colony growth and identification.

Read the detailed description

This pilot study was designed as a randomized, controlled trial comparing clinical outcomes and contamination rates in jet nebulizers versus vibrating mesh nebulizers. The sample size will be one of consecutive convenience over an entire year (September 2013-September 2014) to include all seasons. The study will be performed at Rush University Medical Center (RUMC) in Chicago, IL.

Each mechanically ventilated patient within inclusion criteria, with a physician order for aerosol treatment, will be randomized to either the jet nebulizer or mesh nebulizer group using SPSS computer software. The respiratory care staff will place the nebulization device in the ventilator circuit per hospital protocol. Both devices, jet and mesh nebulizers, are currently standard practice; therefore hospital protocol will be followed regarding placement and administration of ordered aerosol treatment.

The study subject will remain on the device to which they were randomized for the duration of their hospital stay to obtain clinical outcome data. Study staff to be notified of patient extubation from mechanical ventilation, discharge from intensive care unit, or expiration; this will conclude participant involvement in the study. Retrospective clinical outcome data will be obtained from the subject's electronic medical chart at conclusion of study.

Retrospective data to include:

  1. LOS in ICU (days)
  2. LOS on mechanical ventilator (days)
  3. Drug administration information
  4. Drug and dose ordered
  5. Number of treatments delivered
  6. Treatment type
  • Continuous
  • Intermittent
  1. Ventilator-Associated Tracheobronchitis (# VATs)16
  2. Fever, increased volume and purulence of secretions, a positive culture (quantitative or semi-quantitative) of a respiratory sample (tracheal aspirates or bronchoscopic specimens), and the absence of a new or an evolving pulmonary infiltrate in the chest x-ray in a patient on mechanical ventilation >48 hours
  3. Ventilator-Associated Events in Adults15
  4. Ventilator-Associated Condition (# VACs)
  • After a period of stability or improvement on the ventilator, the patient has at least one of the following indications of worsening oxygenation:
  • Minimum daily FiO2 values increase ≥ 0.20 over baseline and remain at or above that increased level for ≥ 2 calendar days. -
  • Minimum daily PEEP values increase ≥ 3 cm H2O over baseline and remain at or above that increased level for ≥ 2 calendar days.
  1. Infection-related Ventilator-Associated Complication (# IVACs)
  • On or after calendar day 3 of mechanical ventilation and within 2 calendar days before or after the onset of worsening oxygenation, the patient meets both of the following criteria:
  • Temperature > 38˚ C or < 36˚ C, or white blood cell count ≥ 12,000 cells/mm3 or ≤ 4,000 cells/mm3. AND
  • A new antimicrobial agent(s) is started, and is continued for ≥ 4 calendar days.
  1. Possible Ventilator-Associated Pneumonia (# Possible VAPs)
  • On or after calendar day 3 of mechanical ventilation and within 2 calendar days before or after the onset of worsening oxygenation, ONE of the following criteria is met:
  • Purulent respiratory secretions
  • Positive culture
  1. Probably Ventilator-Associated Pneumonia (# Probable VAPs)
  • On or after calendar day 3 of mechanical ventilation and within 2 calendar days before or after the onset of worsening oxygenation, ONE of the following criteria is met:
  • Purulent respiratory secretions (from one or more specimen collections- and defined as for possible VAP) and one of the following (positive culture of endotracheal aspirate, positive culture of bronchoalveolar lavage, positive culture of lung tissue, positive culture of protected specimen brush
  • One of the following without requirement for purulent respiratory secretions (positive pleural fluid culture, positive lung histopathology, positive diagnostic test for Legionella, positive diagnostic test on respiratory secretions for influenza virus, respiratory syncytial virus, adenovirus, parainfluenza virus)

The Jet Nebulizer Protocol:

  • Physician order received for subject; randomization to jet nebulizer occurred.
  • Jet nebulizer, Misty Max 10™ (Carefusion, CA), placed into spring-loaded t-piece between the humidifier and the ventilator (approximately 15 cm from the gas outlet).
  • Aerosol treatment delivered per physician order at flow rates of 8-10 L/min.
  • Jet nebulizer to be replaced every 3 days per hospital protocol.
  1. Prior to every nebulizer change or every 3 days, study staff to be notified in order to obtain cultures.
  2. Cultures
  • Jet Nebulizer Culture (3 plates): Sample to be collected from jet nebulizer by running oxygen at a flow of 8-10 L/min through nebulizer (3 mL normal saline in the reservoir) while directing the nebulizer towards plate for 1 minute. Process to be repeated for 3 different plates. Plates to be labeled, have edges sealed with tape, be placed in biohazard bag and sent to microbiology lab for analysis.
  1. Plate 1: MacConkey agar (id gram (-) organisms)
  2. Plate 2: Chocolate agar (id fastidious organisms)
  3. Plate 3: Blood agar (id gram(+) and gram(-) organisms)
  • Ventilator Circuit Culture: Material to be collected from rim of inspiratory ventilator circuit at wye by rubbing a sterile swab along circuit 3x in a circular motion. Swab to be sealed in test tube with lid and sent to lab for analysis.
  • Sputum samples: Data obtained per electronic medical chart. Sputum sample data to be analyzed in study when ordered by physician.
  • After obtaining cultures, the jet nebulizer will be replaced with new one and labeled per hospital protocol.
  • Further cultures are not necessary unless patient is identified by study staff to have VAE. (Appendix A)
  • Study staff to be notified of patient extubation from mechanical ventilation, discharge from intensive care unit or expiration.

The Vibrating Mesh Nebulizer protocol:

  • Physician order received for subject; randomization to vibrating mesh nebulizer occurred.
  • Aeroneb® Solo (Aerogen, Galway, Ireland) vibrating mesh nebulizer to be placed before the heater on the "dry side" of the heater water chamber on the inspiratory ventilator circuit.
  • Aerosol treatment delivered per physician order.
  • Mesh nebulizer to be replaced every 30 days per hospital protocol.
  1. Prior to every nebulizer change or every 3 days, study staff to be notified in order to obtain cultures.
  2. Cultures
  • Vibrating Mesh Nebulizer Culture (3 plates): Sample to be collected from vibrating mesh nebulizer while directing the nebulizer(3 mL normal saline in the reservoir) towards plate for 1 minute. Process to be repeated for 3 different plates. Plates to be labeled, have edges sealed with tape, be placed in biohazard bag and sent to microbiology lab for analysis.
  1. Plate 1: MacConkey agar (id gram (-) organisms)
  2. Plate 2: Chocolate agar (id fastidious organisms)
  3. Plate 3: Blood agar (id gram(+) and gram(-) organisms)
  • Ventilator Circuit Culture: Material to be collected from rim of inspiratory ventilator circuit at wye by rubbing a sterile swab along circuit 3x in a circular motion. Swab to be sealed in test tube with lid and sent to lab for analysis.
  • Sputum samples: Data obtained per electronic medical chart. Sputum sample data to be analyzed in study when ordered by physician.
  • Vibrating mesh nebulizer replaced with new one and labeled per hospital protocol.
  • Further cultures not necessary unless patient identified by study staff to have VAE. (appendix A)
  • Study staff to be notified immediately of patient extubation from mechanical ventilation, discharge from intensive care unit or expiration.
Being tested
Vibrating Mesh Nebulizer Arm, Jet Nebulizer Arm
Keywords
Ventilators, mechanical, Aerosol Drug Therapy, Nebulizers, Equipment Contamination, vibrating mesh nebulizer, jet nebulizer, mechanical ventilation, ventilator associated event, ventilator associated tracheobronchitis
Medical subject headings
Respiratory Insufficiency

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Vibrating Mesh Nebulizer ArmDevice

    Also called Aeroneb Solo (Aerogen, Galway, Ireland)

    • Physician order received for subject, randomization to vibrating mesh nebulizer occurred.
    • Aeroneb® Solo (Aerogen, Galway, Ireland) vibrating mesh nebulizer to be placed before the heater on the "dry side" of the heater water chamber on the inspiratory ventilator circuit.
    • Aerosol treatment delivered per physician order.
    • Mesh nebulizer to be replaced every 30 days per hospital protocol. a. Prior to every nebulizer change or every 3 days, study staff to be notified in order to obtain cultures.
  • Jet Nebulizer ArmDevice

    Also called Misty Max 10 nebulizer (Carefusion, California)

    • Physician order received for subject, randomization to jet nebulizer occurred.
    • Jet nebulizer, Misty Max 10™ (Carefusion, CA), placed into spring loaded t-piece between the humidifier and the ventilator (approximately 15 cm from the gas outlet).
    • Aerosol treatment delivered per physician order at flow rates of 8-10 L/min.
    • Jet nebulizer to be replaced every 3 days per hospital protocol. a. Prior to every nebulizer change or every 3 days, study staff to be notified in order to obtain cultures.
Study groups in NCT02056119
Study groupRoleWhat they receive
Jet Nebulizer ArmActive comparatorThe Jet Nebulizer Protocol: * Physician order received for subject, randomization to jet nebulizer occurred. * Jet nebulizer, Misty Max 10™ (Carefusion, CA), placed into spring loaded t-piece between the humidifier and the ventilator (approximately 15 cm from the gas outlet). * Aerosol treatment delivered per physician order at flow rates of 8-10 L/min. * Jet nebulizer to be replaced every 3 days per hospital protocol. a. Prior to every nebulizer change or every 3 days, study staff to be notified in order to obtain cultures.
Receives: Device: Jet Nebulizer Arm
Vibrating Mesh Nebulizer ArmExperimental* Physician order received for subject, randomization to vibrating mesh nebulizer occurred. * Aeroneb® Solo (Aerogen, Galway, Ireland) vibrating mesh nebulizer to be placed before the heater on the "dry side" of the heater water chamber on the inspiratory ventilator circuit. * Aerosol treatment delivered per physician order. * Mesh nebulizer to be replaced every 30 days per hospital protocol. a. Prior to every nebulizer change or every 3 days, study staff to be notified in order to obtain cultures.
Receives: Device: Vibrating Mesh Nebulizer Arm

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Venilator Associated Events (VAE)

    Ventilator associated conditions (VAC) and infection related ventilator associated conditions (IVAC) were identified based on the 2013 NHSN Surveillance for VAEs (e,g., "See page 92 at https://www.cdc.gov/nhsn/PDFs/pscManual/validation/2013-PSC-Manual-validate.pdf for detailed criteria.")

    Measured: duration of mechanical ventilation or discharge from the intensive care unit

Secondary outcomes (3)
  1. Participants With Bacterial Growth

    While on mechanical ventilator, bacterial growth will be assessed from the vent circuit and nebulizer, and participant sputum.

    Measured: duration of mechanical ventilation or discharge from the intensive care unit

  2. Length of Stay in Intensive Care Unit

    Total length of stay in intensive care unit in days

    Measured: discharge from the intensive care unit

  3. Days on Mechanical Ventilation

    Total days spent on Mechanical Ventilator

    Measured: discharge from the intensive care unit

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Feb 2014 (estimated)
  2. Study startSep 2013
  3. Primary completionOct 2014
  4. Study completionOct 2014

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Basic science
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
120 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT02056119
Sponsor's protocol ID
13070203
Status last verified
Mar 2023
First submitted
15 Jan 2014
Last updated
21 Mar 2023
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Vibrating Mesh Nebulizer Arm and Jet Nebulizer Arm in people with Respiratory Insufficiency, run by Rush University Medical Center at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 21 Mar 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 21 Mar 2023). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Venilator Associated Events (VAE) (time frame: duration of mechanical ventilation or discharge from the intensive care unit). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Mar 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in