Class I or II Indication for Implantation of a Single Chamber Ventricular Pacemaker According to ACC/AHA/HRS 2001 Guidelines and Any National GuidelinesNCT02004873
Micra Transcatheter Pacing Study
A study testing Micra Pacemaker Implant in people with Class I or II Indication for Implantation of a Single Chamber Ventricular Pacemaker According to ACC/AHA/HRS 2001 Guidelines and Any National Guidelines, run by Medtronic Cardiac Rhythm and Heart Failure at 56 sites in 19 countries.
Trial summary
The purpose of this clinical study is to evaluate the safety and efficacy of the Micra Transcatheter Pacing System and to assess long term performance. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Class I or II Indication for Implantation of a Single Chamber Ventricular Pacemaker According to ACC/AHA/HRS 2001 Guidelines and Any National Guidelines
- What is being tested?
- Micra Pacemaker Implant
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 744 participants
- Where
- 56 sitesin 19 countries
- Study dates
- Nov 2013to May 2017
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subjects who have a Class I or II indication for implantation of a single chamber ventricular pacemaker according to ACC/AHA/HRS 2008 guidelines and any national guidelines
- Subjects who are able and willing to undergo the study requirements and are expected to be geographically stable for the duration of the follow-up.
- Subjects who are at least 18 years of age (or older, if required by local law).
Who cannot join
- Subjects who are entirely pacemaker dependent (escape rhythm <30 bpm). (Please note: Subjects who are entirely pacemaker dependent (escape rhythm <30 bpm) can now be included in the study. Medtronic notified all sites on July 23, 2014 that the restriction against pacemaker dependent subjects was lifted, following review of the Early Performance Assessment.)
- Subject has an existing or prior pacemaker, ICD or CRT device implant.
- Subject has unstable angina pectoris or has had an acute myocardial infarction (AMI) in the 30 days prior to eligibility assessment.
- Subjects with current implantation of neurostimulator or any other chronically implanted device which uses current in the body. Note that a temporary pacing wire is allowed.
- Subjects with a mechanical tricuspid valve, implanted vena cava filter, or left ventricular assist device (LVAD).
- Subjects who are morbidly obese and physician believes telemetry communication of ≤5 inches (12.7 cm) could not be obtained with programmer head.
Show all 14Show fewer
- Subjects whose femoral venous anatomy is unable to accommodate a 23 French introducer sheath or implant on the right side of the heart (for example, due to obstructions or severe tortuosity) in the opinion of the implanter.
- Subjects who are considered as unable to tolerate an urgent sternotomy
- Subjects with a known intolerance to Nickel-Titanium (Nitinol) Alloy.
- Subjects for whom a single dose of 1.0mg dexamethasone acetate may be contraindicated.
- Subjects with a life expectancy of less than 12- months.
- Subjects who are currently enrolled or planning to participate in a potentially confounding drug or device trial during the course of this study. Coenrollment in concurrent trials is only allowed when document pre-approval is obtained from the Medtronic study manager.
- Pregnant women, or women of child bearing potential and who are not on a reliable form of birth control.
- Subjects with exclusion criteria required by local law (e.g. age, breast feeding, etc.).
Trial locations and contacts
56 sites in 19 countries.
56 sites in 19 countries
United States30 sites
Emory University Hospital
Atlanta, Georgia, 30322-1059
University of Virginia Medical Center
Charlottesville, Virginia, 22908
Cleveland Clinic
Cleveland, Ohio, 44195
The Ohio State University
Columbus, Ohio, 43210
Baylor Research Institute
Dallas, Texas, 75226
Duke University Medical Center
Durham, North Carolina, 27710
The Stern Cardiovascular Clinic
Germantown, Tennessee, 38138
St. Luke's Medical Center
Houston, Texas, 77030
Baptist Heart Specialists
Jacksonville, Florida, 32207
Mid America Heart Institute
Kansas City, Missouri, 64111
Scripps
La Jolla, California, 92037
Lancaster Heart & Vascular Research Institute
Lancaster, Pennsylvania, 17604
Cedars-Sinai Medical Center
Los Angeles, California, 90048
North Shore LIJ Health System
Manhasset, New York, 11030
Baptist Hospital of Miami
Miami, Florida, 33176
Aurora Cardiovascular Services
Milwaukee, Wisconsin, 53215
Minneapolis Heart Institute Foundation
Minneapolis, Minnesota, 55407-1195
Morristown Memorial Hospital
Morristown, New Jersey, 07960
Vanderbilt University Medical Center
Nashville, Tennessee, 37232
Yale University
New Haven, Connecticut, 06520
NYU Langone Medical Center
New York, New York, 10016-4303
University of Oklahoma Health Science Center (OUHSC)
Oklahoma City, Oklahoma, 73104-5033
Oklahoma Heart Hospital
Oklahoma City, Oklahoma, 73120
University of Pittsburgh Medical Center UPMC Presbyterian
Pittsburgh, Pennsylvania, 15213-2536
Providence Health & Services
Portland, Oregon, 97225
The Valley Hospital
Ridgewood, New Jersey, 07450
CentraCare Heart & Vascular Center
Saint Cloud, Minnesota, 56303
Iowa Heart Center
West Des Moines, Iowa, 50266
Lankenau Institute for Medical Research
Wynnewood, Pennsylvania, 19096
Michigan Heart
Ypsilanti, Michigan, 48197
Japan4 sites
National Cerebral and Cardiovascular Center
Osaka
Showa University Hospital
Shinagawa-Ku
Kyorin University Hospital
Tokyo
Yokohama City University Hospital
Yokohama
India3 sites
CARE Hospitals
Hyderabad
All India Institute of Medical Sciences
New Delhi
Govind Ballabh Pant Hospital
New Delhi
Netherlands3 sites
Academisch Medisch Centrum (AMC)
Amsterdam
Catharina Ziekenhuis
Eindhoven
St. Antonius Ziekenhuis - Locatie Nieuwegein
Nieuwegein
Canada2 sites
Montreal Heart Institute
Montreal, Quebec
Institut Universitaire de Cardiologie et de Pneumologie de Québec (IUCPQ)
Québec
China1 site
Fuwai Hospital Chinese Academy of Medical Sciences and Peking Union Medical College
Beijing
Italy1 site
Azienda Ospedaliero Universitaria Pisana - Stabilimento Santa Chiara
Pisa
Malaysia1 site
Institut Jantung Negara - National Heart Institute
Kuala Lumpur
United Kingdom1 site
Southampton General Hospital - University Hospital Southampton NHS Foundation Trust
Southampton
About this study
The purpose of this clinical study is to evaluate the safety and efficacy of the Micra Transcatheter Pacing System and to assess long term performance.
Read the detailed description
The study is being conducted in 56 sites located around the world, including 30 sites in the United States (U.S.).
Up to 780 subjects were planned to be enrolled (i.e. consented) to allow up to 720 subjects to be implanted enabling at least 600 subjects to be followed for at least 12-months post-implant.
There are two primary objectives in this study (one safety and one efficacy). The primary safety objective of the study is to evaluate major complications related to the Micra system or procedure. The primary safety endpoint was pre-specified to be evaluated at 6-months (183 days) post-implant. The primary efficacy objective, Micra pacing capture thresholds, was also pre-specified to be evaluated six months post-implant. This study also has a separate long term safety objective that will provide additional long-term safety data following potential regulatory submissions.
All subjects will be followed until official study closure (official study closure is defined as when Medtronic and/or FDA requirements have been satisfied per the Clinical Investigational Plan and/or by a decision by Medtronic or regulatory authority).
Additionally, the Micra Accelerometer Sensor Sub-Study (MASS) is being conducted at 4 centers already active in the Micra study in Austria, Spain, Hungary and France. Forty (40) subjects were enrolled in the Sub-Study, and enrollment in the Sub-Study was complete as of March 31, 2016. The purpose of the Sub-Study is to test feasibility for future enhancements in the Micra device functionalities.
An algorithm was designed to sense the atrial contraction using the Micra accelerometer.
- Being tested
- Micra Pacemaker Implant
- Keywords
- pacemaker, leadless, single chamber
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Micra Pacemaker ImplantDevice
| Study group | Role | What they receive |
|---|---|---|
| Micra Pacemaker Implant | Experimental | Not described Receives: Device: Micra Pacemaker Implant |
What is being measured
The primary outcome is the main question the study is designed to answer.
Major Complications
Micra system and/or procedure related major complication free rate at 6-months post-implant.
Measured: Implant to 6 Months Post Implant
Pacing Capture Threshold
Subjects that have an adequate pacing capture threshold (PCT) at the 6-month post-implant visit, which is defined as PCT <=2 volts at 0.24 ms pulse width and the increase in PCT from implant to 6 months <=1.5 volts. The pacing capture threshold is the minimal electrical stimulus required to produce consistent cardiac depolarization. It is the minimum amount of energy that is required for a pacemaker to pace the heart.
Measured: 6 Months Post Implant
Secondary outcomes (2)
Ventricular Capture Management Threshold
Subjects that have a ventricular capture management threshold (VCMT) that is within 0.5 Volts of the manual (auto decrement) PCT (at 0.24 ms pulse width) at the 6-month post-implant visit. The VCMT is an automatically measured pacing capture threshold that is measured by the Micra device's pacing algorithm. In contrast, the manual (auto decrement) pacing capture threshold is measured by the clinician during a study visit.
Measured: 6 Months Post Implant
Rate Response Operation of Micra
Assessment of whether the Micra sensor-indicated rate derived from the input of the accelerometer during the Minnesota Pacemaker Response Exercise Protocol (M-PREP) treadmill test conducted at the 3-month and 6-month follow-up visits was proportional to the workload. The sensor-indicated rate (in min^-1) and workload (in METS) were normalized for each subject relative to their minimum and maximum possible values so the normalized values have a minimum possible value of zero and a maximum possible value of 1. These normalized values were used in a random effect linear regression model to assess the relationship between the sensor-indicated rate and workload via estimation of the Kay-Wilkoff slope parameter. The tests at 3-month and 6-month visits were combined in one analysis.
Measured: 3 Months and 6 Months Post Implant (combined analysis)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Dec 2013 (estimated)
- Study startNov 2013
- Primary completionMay 2015
- Study completionMay 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (11)Papers the sponsor has linked to this study.
- Other trials for Class I or II Indication for Implantation of a Single Chamber Ventricular Pacemaker According to ACC/AHA/HRS 2001 Guidelines and Any National GuidelinesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 744 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medtronic Cardiac Rhythm and Heart Failure
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Dwight Reynolds, Study chair, University of OklahomaPhilippe Ritter, Study chair, Hôpital Haut-Lévêque
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02004873
- Sponsor's protocol ID
- Micra
- Status last verified
- Dec 2017
- First submitted
- 3 Dec 2013
- Last updated
- 17 Jan 2018
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
Publications
Piccini JP, Cunnane R, Steffel J, El-Chami MF, Reynolds D, Roberts PR, Soejima K, Steinwender C, Garweg C, Chinitz L, Ellis CR, Stromberg K, Fagan DH, Mont L. Development and validation of a risk score for predicting pericardial effusion in patients undergoing leadless pacemaker implantation: experience with the Micra transcatheter pacemaker. Europace. 2022 Jul 21;24(7):1119-1126. doi: 10.1093/europace/euab315.
PubMed 35025987El-Chami MF, Shinn T, Bansal S, Martinez-Sande JL, Clementy N, Augostini R, Ravindran B, Sagi V, Ramanna H, Garweg C, Roberts PR, Soejima K, Stromberg K, Fagan DH, Zuniga N, Piccini JP. Leadless pacemaker implant with concomitant atrioventricular node ablation: Experience with the Micra transcatheter pacemaker. J Cardiovasc Electrophysiol. 2021 Mar;32(3):832-841. doi: 10.1111/jce.14881. Epub 2021 Jan 23.
PubMed 33428248Garg A, Koneru JN, Fagan DH, Stromberg K, Padala SK, El-Chami MF, Roberts PR, Piccini JP, Cheng A, Ellenbogen KA. Morbidity and mortality in patients precluded for transvenous pacemaker implantation: Experience with a leadless pacemaker. Heart Rhythm. 2020 Dec;17(12):2056-2063. doi: 10.1016/j.hrthm.2020.07.035. Epub 2020 Aug 4.
PubMed 32763431Tjong FVY, Beurskens NEG, de Groot JR, Waweru C, Liu S, Ritter P, Reynolds D, Wilde AAM, Knops RE; Micra Investigators. Health-related quality of life impact of a transcatheter pacing system. J Cardiovasc Electrophysiol. 2018 Dec;29(12):1697-1704. doi: 10.1111/jce.13726. Epub 2018 Oct 15.
PubMed 30168233El-Chami MF, Al-Samadi F, Clementy N, Garweg C, Martinez-Sande JL, Piccini JP, Iacopino S, Lloyd M, Vinolas Prat X, Jacobsen MD, Ritter P, Johansen JB, Tondo C, Liu F, Fagan DH, Eakley AK, Roberts PR. Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control. Heart Rhythm. 2018 Dec;15(12):1800-1807. doi: 10.1016/j.hrthm.2018.08.005. Epub 2018 Aug 10.
PubMed 30103071Okabe T, El-Chami MF, Lloyd MS, Buck B, Gornick CC, Moore JC, Augostini RS, Hummel JD. Leadless pacemaker implantation and concurrent atrioventricular junction ablation in patients with atrial fibrillation. Pacing Clin Electrophysiol. 2018 May;41(5):504-510. doi: 10.1111/pace.13312. Epub 2018 Apr 16.
PubMed 29476660Soejima K, Asano T, Ishikawa T, Kusano K, Sato T, Okamura H, Matsumoto K, Taguchi W, Stromberg K, Lande J, Kobayashi Y; Micra Transcatheter Pacing Study Group. Performance of Leadless Pacemaker in Japanese Patients vs. Rest of the World - Results From a Global Clinical Trial. Circ J. 2017 Oct 25;81(11):1589-1595. doi: 10.1253/circj.CJ-17-0259. Epub 2017 May 30.
PubMed 28566657Lloyd M, Reynolds D, Sheldon T, Stromberg K, Hudnall JH, Demmer WM, Omar R, Ritter P, Hummel J, Mont L, Steinwender C, Duray GZ. Rate adaptive pacing in an intracardiac pacemaker. Heart Rhythm. 2017 Feb;14(2):200-205. doi: 10.1016/j.hrthm.2016.11.016. Epub 2016 Nov 15.
PubMed 27871854Reynolds D, Duray GZ, Omar R, Soejima K, Neuzil P, Zhang S, Narasimhan C, Steinwender C, Brugada J, Lloyd M, Roberts PR, Sagi V, Hummel J, Bongiorni MG, Knops RE, Ellis CR, Gornick CC, Bernabei MA, Laager V, Stromberg K, Williams ER, Hudnall JH, Ritter P; Micra Transcatheter Pacing Study Group. A Leadless Intracardiac Transcatheter Pacing System. N Engl J Med. 2016 Feb 11;374(6):533-41. doi: 10.1056/NEJMoa1511643. Epub 2015 Nov 9.
PubMed 26551877Ritter P, Duray GZ, Steinwender C, Soejima K, Omar R, Mont L, Boersma LV, Knops RE, Chinitz L, Zhang S, Narasimhan C, Hummel J, Lloyd M, Simmers TA, Voigt A, Laager V, Stromberg K, Bonner MD, Sheldon TJ, Reynolds D; Micra Transcatheter Pacing Study Group. Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study. Eur Heart J. 2015 Oct 1;36(37):2510-9. doi: 10.1093/eurheartj/ehv214. Epub 2015 Jun 4.
PubMed 26045305Ritter P, Duray GZ, Zhang S, Narasimhan C, Soejima K, Omar R, Laager V, Stromberg K, Williams E, Reynolds D; Micra Transcatheter Pacing Study Group. The rationale and design of the Micra Transcatheter Pacing Study: safety and efficacy of a novel miniaturized pacemaker. Europace. 2015 May;17(5):807-13. doi: 10.1093/europace/euv026. Epub 2015 Apr 7.
PubMed 25855677
Study at a glance
From the registry record, last updated by the sponsor on 17 Jan 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Micra Transcatheter Pacing Study
- ClinicalTrials.gov ID
- NCT02004873
- Acronym / sponsor ID
- Micra
- Keywords
- pacemaker, leadless, single chamber
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 744 participants (actual)
- Lead sponsor
- Medtronic Cardiac Rhythm and Heart FailureIndustry (pharma, biotech, devices)
- Study start
- Nov 2013 (actual)
- Primary completion
- May 2015 (actual)
- Study completion
- May 2017 (actual)
- First posted
- 9 Dec 2013 (estimated)
- Results
- Posted 5 Jan 2017
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this clinical study is to evaluate the safety and efficacy of the Micra Transcatheter Pacing System and to assess long term performance.
Detailed description
The study is being conducted in 56 sites located around the world, including 30 sites in the United States (U.S.).
Up to 780 subjects were planned to be enrolled (i.e. consented) to allow up to 720 subjects to be implanted enabling at least 600 subjects to be followed for at least 12-months post-implant.
There are two primary objectives in this study (one safety and one efficacy). The primary safety objective of the study is to evaluate major complications related to the Micra system or procedure. The primary safety endpoint was pre-specified to be evaluated at 6-months (183 days) post-implant. The primary efficacy objective, Micra pacing capture thresholds, was also pre-specified to be evaluated six months post-implant. This study also has a separate long term safety objective that will provide additional long-term safety data following potential regulatory submissions.
All subjects will be followed until official study closure (official study closure is defined as when Medtronic and/or FDA requirements have been satisfied per the Clinical Investigational Plan and/or by a decision by Medtronic or regulatory authority).
Additionally, the Micra Accelerometer Sensor Sub-Study (MASS) is being conducted at 4 centers already active in the Micra study in Austria, Spain, Hungary and France. Forty (40) subjects were enrolled in the Sub-Study, and enrollment in the Sub-Study was complete as of March 31, 2016. The purpose of the Sub-Study is to test feasibility for future enhancements in the Micra device functionalities.
An algorithm was designed to sense the atrial contraction using the Micra accelerometer.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Micra Pacemaker Implant | Experimental | Device: Micra Pacemaker Implant |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Subjects who have a Class I or II indication for implantation of a single chamber ventricular pacemaker according to ACC/AHA/HRS 2008 guidelines and any national guidelines
- Subjects who are able and willing to undergo the study requirements and are expected to be geographically stable for the duration of the follow-up.
- Subjects who are at least 18 years of age (or older, if required by local law).
Key exclusion criteria (14 listed)
- Subjects who are entirely pacemaker dependent (escape rhythm <30 bpm). (Please note: Subjects who are entirely pacemaker dependent (escape rhythm <30 bpm) can now be included in the study. Medtronic notified all sites on July 23, 2014 that the restriction against pacemaker dependent subjects was lifted, following review of the Early Performance Assessment.)
- Subject has an existing or prior pacemaker, ICD or CRT device implant.
- Subject has unstable angina pectoris or has had an acute myocardial infarction (AMI) in the 30 days prior to eligibility assessment.
- Subjects with current implantation of neurostimulator or any other chronically implanted device which uses current in the body. Note that a temporary pacing wire is allowed.
- Subjects with a mechanical tricuspid valve, implanted vena cava filter, or left ventricular assist device (LVAD).
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Micra Pacemaker Implant | Device | Micra Pacemaker Implant |
Primary outcome
Major Complications
Time frame: Implant to 6 Months Post Implant
Micra system and/or procedure related major complication free rate at 6-months post-implant.
Pacing Capture Threshold
Time frame: 6 Months Post Implant
Subjects that have an adequate pacing capture threshold (PCT) at the 6-month post-implant visit, which is defined as PCT <=2 volts at 0.24 ms pulse width and the increase in PCT from implant to 6 months <=1.5 volts. The pacing capture threshold is the minimal electrical stimulus required to produce consistent cardiac depolarization. It is the minimum amount of energy that is required for a pacemaker to pace the heart.
2 secondary outcomes
Ventricular Capture Management Threshold
Time frame: 6 Months Post Implant
Rate Response Operation of Micra
Time frame: 3 Months and 6 Months Post Implant (combined analysis)
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Jan 2018.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Derived from this study: PubMed 35025987Piccini JP, Cunnane R, Steffel J, El-Chami MF, Reynolds D, Roberts PR, Soejima K, Steinwender C, Garweg C, Chinitz L, Ellis CR, Stromberg K, Fagan DH, Mont L. Development and validation of a risk score for predicting pericardial effusion in patients undergoing leadless pacemaker implantation: experience with the Micra transcatheter pacemaker. Europace. 2022 Jul 21;24(7):1119-1126. doi: 10.1093/europace/euab315.
- Derived from this study: PubMed 33428248El-Chami MF, Shinn T, Bansal S, Martinez-Sande JL, Clementy N, Augostini R, Ravindran B, Sagi V, Ramanna H, Garweg C, Roberts PR, Soejima K, Stromberg K, Fagan DH, Zuniga N, Piccini JP. Leadless pacemaker implant with concomitant atrioventricular node ablation: Experience with the Micra transcatheter pacemaker. J Cardiovasc Electrophysiol. 2021 Mar;32(3):832-841. doi: 10.1111/jce.14881. Epub 2021 Jan 23.
- Derived from this study: PubMed 32763431Garg A, Koneru JN, Fagan DH, Stromberg K, Padala SK, El-Chami MF, Roberts PR, Piccini JP, Cheng A, Ellenbogen KA. Morbidity and mortality in patients precluded for transvenous pacemaker implantation: Experience with a leadless pacemaker. Heart Rhythm. 2020 Dec;17(12):2056-2063. doi: 10.1016/j.hrthm.2020.07.035. Epub 2020 Aug 4.
- Derived from this study: PubMed 30168233Tjong FVY, Beurskens NEG, de Groot JR, Waweru C, Liu S, Ritter P, Reynolds D, Wilde AAM, Knops RE; Micra Investigators. Health-related quality of life impact of a transcatheter pacing system. J Cardiovasc Electrophysiol. 2018 Dec;29(12):1697-1704. doi: 10.1111/jce.13726. Epub 2018 Oct 15.
- Derived from this study: PubMed 30103071El-Chami MF, Al-Samadi F, Clementy N, Garweg C, Martinez-Sande JL, Piccini JP, Iacopino S, Lloyd M, Vinolas Prat X, Jacobsen MD, Ritter P, Johansen JB, Tondo C, Liu F, Fagan DH, Eakley AK, Roberts PR. Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control. Heart Rhythm. 2018 Dec;15(12):1800-1807. doi: 10.1016/j.hrthm.2018.08.005. Epub 2018 Aug 10.
- Derived from this study: PubMed 29476660Okabe T, El-Chami MF, Lloyd MS, Buck B, Gornick CC, Moore JC, Augostini RS, Hummel JD. Leadless pacemaker implantation and concurrent atrioventricular junction ablation in patients with atrial fibrillation. Pacing Clin Electrophysiol. 2018 May;41(5):504-510. doi: 10.1111/pace.13312. Epub 2018 Apr 16.
- Derived from this study: PubMed 28566657Soejima K, Asano T, Ishikawa T, Kusano K, Sato T, Okamura H, Matsumoto K, Taguchi W, Stromberg K, Lande J, Kobayashi Y; Micra Transcatheter Pacing Study Group. Performance of Leadless Pacemaker in Japanese Patients vs. Rest of the World - Results From a Global Clinical Trial. Circ J. 2017 Oct 25;81(11):1589-1595. doi: 10.1253/circj.CJ-17-0259. Epub 2017 May 30.
- Derived from this study: PubMed 27871854Lloyd M, Reynolds D, Sheldon T, Stromberg K, Hudnall JH, Demmer WM, Omar R, Ritter P, Hummel J, Mont L, Steinwender C, Duray GZ. Rate adaptive pacing in an intracardiac pacemaker. Heart Rhythm. 2017 Feb;14(2):200-205. doi: 10.1016/j.hrthm.2016.11.016. Epub 2016 Nov 15.
- Derived from this study: PubMed 26551877Reynolds D, Duray GZ, Omar R, Soejima K, Neuzil P, Zhang S, Narasimhan C, Steinwender C, Brugada J, Lloyd M, Roberts PR, Sagi V, Hummel J, Bongiorni MG, Knops RE, Ellis CR, Gornick CC, Bernabei MA, Laager V, Stromberg K, Williams ER, Hudnall JH, Ritter P; Micra Transcatheter Pacing Study Group. A Leadless Intracardiac Transcatheter Pacing System. N Engl J Med. 2016 Feb 11;374(6):533-41. doi: 10.1056/NEJMoa1511643. Epub 2015 Nov 9.
- Derived from this study: PubMed 26045305Ritter P, Duray GZ, Steinwender C, Soejima K, Omar R, Mont L, Boersma LV, Knops RE, Chinitz L, Zhang S, Narasimhan C, Hummel J, Lloyd M, Simmers TA, Voigt A, Laager V, Stromberg K, Bonner MD, Sheldon TJ, Reynolds D; Micra Transcatheter Pacing Study Group. Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study. Eur Heart J. 2015 Oct 1;36(37):2510-9. doi: 10.1093/eurheartj/ehv214. Epub 2015 Jun 4.
- Derived from this study: PubMed 25855677Ritter P, Duray GZ, Zhang S, Narasimhan C, Soejima K, Omar R, Laager V, Stromberg K, Williams E, Reynolds D; Micra Transcatheter Pacing Study Group. The rationale and design of the Micra Transcatheter Pacing Study: safety and efficacy of a novel miniaturized pacemaker. Europace. 2015 May;17(5):807-13. doi: 10.1093/europace/euv026. Epub 2015 Apr 7.
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Dwight Reynolds study chair
University of Oklahoma
Philippe Ritter study chair
Hôpital Haut-Lévêque
56 sites in 19 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Micra Pacemaker Implant in people with Class I or II Indication for Implantation of a Single Chamber Ventricular Pacemaker According to ACC/AHA/HRS 2001 Guidelines and Any National Guidelines, run by Medtronic Cardiac Rhythm and Heart Failure at 56 sites in 19 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 14 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 17 Jan 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 56 sites in United States, Japan, India, Netherlands, Canada and 14 more countries. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 5 Jan 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Major Complications (time frame: Implant to 6 Months Post Implant). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02004873, which also lists 11 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Jan 2018.