Insulin Requiring DiabetesNCT01991470
CEP249 Pediatric Accuracy Study
A study testing Enlite sensors in people with Insulin Requiring Diabetes, run by Medtronic MiniMed, Inc. at 11 sites in United States.
Trial summary
The purpose of this study is to evaluate the Enlite Sensor™ and Enlite 3 Sensor performance in pediatric patients with insulin requiring diabetes at the beginning, middle and end of sensor wear. Read more about this study
- Who is it for?
- Ages 2 to 18 years
- Conditions the study is for
- Insulin Requiring Diabetes
- What is being tested?
- Enlite sensors
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 186 participants
- Where
- 11 sitesUnited States
- Study dates
- Mar 2015to Dec 2016
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 2 to 18 years
- All sexes
- No healthy volunteers
- Child, Adult
Who may be able to join
- Subject is 2-18 years of age at time of screening
- Subject has been diagnosed with insulin requiring diabetes mellitus for at least one year.
- Subject is willing to perform greater than or equal to 4 finger stick blood glucose measurements daily
- Subject is willing to perform required sensor calibrations
- Subject is willing to wear the system (Guardian Mobile application, pumps, sensors, meter) continuously throughout the study
- Adequate venous access as assessed by investigator or appropriate staff
Who cannot join
- Subject is unable to tolerate tape adhesive in the area of sensor placement
- Subject has any unresolved adverse skin condition in the area of sensor or device placement (e.g., psoriasis, rash, Staphylococcus infection)
- Subject is actively participating in an investigational study (drug or device) wherein they have received treatment from an investigational study (drug or device) in the last 2 weeks
- Females of child-bearing potential who have a positive pregnancy test at screening or plans to become pregnant during the course of the study
- Subjects with hematocrit lower than the normal age specific reference range per central or local lab testing
Trial locations and contacts
11 sites in 1 country.
11 sites in 1 country
United States11 sites
"Atlanta Diabetes Associates
Atlanta, Georgia, 30318
Barbara Davis Center
Aurora, Colorado, 80045
AMCR Institute
Escondido, California, 92025
Indiana University, Riley Hospital for Children
Indianapolis, Indiana, 46202
University of Iowa Children Hospital
Iowa City, Iowa, 52242
Nemours Children's Clinic
Jacksonville, Florida, 32207
Yale University, Yale Diabetes Research Program
New Haven, Connecticut, 06511
OUHSC Department of Pediatrics
Oklahoma City, Oklahoma, 73104
Rainier Clinical Research Center
Renton, Washington, 98057
SoCal Diabetes
Torrance, California, 90505
Diablo Clinical Research
Walnut Creek, California, 94598
About this study
Official title: A Performance Evaluation of the Enlite™ and Enlite 3 Glucose Sensor to Support Use in Children
The purpose of this study is to evaluate the Enlite Sensor™ and Enlite 3 Sensor performance in pediatric patients with insulin requiring diabetes at the beginning, middle and end of sensor wear.
Read the detailed description
This study is a prospective, single arm, multi-center, in-clinic study.. There will be two consecutive phases of the study:
A total of up to 260 subjects (2-18 years old) will be enrolled at up to 15 investigational centers
Subjects will come for clinic visit for YSI reference glucose testing and for Enlite Sensor™ and Enlite 3 Sensor™ testing. SMBG (Self-Monitoring of Blood Glucose) reference measurement is for subjects 2-6 years of age and cannot tolerate YSI.
Study has a run-in period and a study period with a total of 10 visits
- Conditions
- Insulin Requiring Diabetes
- Being tested
- Enlite sensors
- Keywords
- Insulin requiring diabetes, Children, Sensor, Accuracy
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Enlite sensorsDevice
Subject wears enlite sensor first and followed by enlite 3 sensor.
| Study group | Role | What they receive |
|---|---|---|
| Enlite sensors | Experimental | Each subject will first wear enlite sensors and will come for clinic visit for YSI (Yellow Spring Instruments). Then each subject will wear enlite 3 sensors and will come for clinic visit for YSI (Yellow Spring Instruments) or SMBG (Self-Monitoring of Blood Glucose) testing. SMBG testings are for subjects 2-6 years of age and cannot tolerate YSI. In addition. In addition, subjects aged 2-6 years old will not participate in Enlite phase. They only participate in Enlite 3 phase. Receives: Device: Enlite sensors |
What is being measured
The primary outcome is the main question the study is designed to answer.
Enlite Sensor Accuracy Mean Absolute Relative Difference (MARD), With Lower Serial Number 530G Pump
Enlite Sensor accuracy relative to the YSI (Yellow Spring Instruments) reference. Each subject wore two 530G pumps. The results for the lower serial number pump worn by each subject were arbitrarily selected and pooled across subjects for the primary dataset. MARD = Mean of ((Absolute difference of YSI reference and Sensor glucose values / YSI reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days were pooled together for reporting purpose.
Measured: 6 days
Enlite 3 Sensor Accuracy Mean Absolute Relative Difference (MARD), With the Guardian Mobile System
Enlite 3 Sensor accuracy using Guardian Mobile System compared to YSI or SMBG (Self-Monitoring of Blood Glucose) reference values. For subjects 2-6 years of age, SMBG was used as a reference value if YSI cannot be tolerated. MARD = Mean of ((Absolute difference of reference and Sensor glucose values / reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days will be pooled together for reporting purpose.
Measured: 7 days
Secondary outcomes (6)
Enlite 3 Sensor Accuracy Mean Absolute Relative Difference (MARD), With the GST3C Transmitter
Enlite 3 Sensor accuracy using GST3C transmitter used as a recorder compared to YSI or SMBG reference values. For subjects 2-6 years of age, SMBG was used as a reference value if YSI cannot be tolerated. MARD = Mean of ((Absolute difference of reference and Sensor glucose values / reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days will be pooled together for reporting purpose.
Measured: 7 days
Enlite Sensor Accuracy Mean Absolute Relative Difference (MARD), With Higher Serial Number 530G Pump
Enlite Sensor accuracy relative to the YSI reference. Each subject wore two 530G pumps. The results for the higher serial number pump worn by each subject were arbitrarily selected and pooled across subjects for the secondary dataset. MARD = Mean of ((Absolute difference of YSI reference and Sensor glucose values / YSI reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days were pooled together for reporting purpose.
Measured: 6 Days
Enlite Sensor Accuracy Mean Absolute Relative Difference (MARD), With Lower Serial Number 530G Pump, Using One Additional Calibration During FST
Enlite Sensor accuracy relative to the YSI reference, using one additional calibration during FST. MARD = Mean of ((Absolute difference of YSI reference and Sensor glucose values / YSI reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days were pooled together for reporting purpose.
Measured: 6 Days
Enlite Sensor Accuracy Mean Absolute Relative Difference (MARD), With Higher Serial Number 530G Pump, Using One Additional Calibration During FST
Enlite Sensor accuracy relative to the YSI reference, using one additional calibration during FST. MARD = Mean of ((Absolute difference of YSI reference and Sensor glucose values / YSI reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days were pooled together for reporting purpose.
Measured: 6 Days
Enlite 3 Sensor Accuracy Mean Absolute Relative Difference (MARD), With the Guardian Mobile System, Using One Additional Calibration During FST
Enlite 3 Sensor accuracy using Guardian Mobile System compared to YSI or SMBG reference values, with one additional calibration during FST. For subjects 2-6 years of age, SMBG was used as a reference value if YSI cannot be tolerated. MARD = Mean of ((Absolute difference of reference and Sensor glucose values / reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days will be pooled together for reporting purpose.
Measured: 7 Days
Enlite 3 Sensor Accuracy Mean Absolute Relative Difference (MARD), With GST3C Transmitter, Using One Additional Calibration During FST
Enlite 3 Sensor accuracy using GST3C transmitter used as a recorder compared to YSI or SMBG reference values, with one additional calibration during FST. For subjects 2-6 years of age, SMBG was used as a reference value if YSI cannot be tolerated. MARD = Mean of ((Absolute difference of reference and Sensor glucose values / reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days will be pooled together for reporting purpose.
Measured: 7 Days
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted25 Nov 2013 (estimated)
- Study startMar 2015
- Primary completionDec 2016
- Study completionDec 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Insulin Requiring DiabetesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Intervention model
- Sequential
- Masking
- None (open label)
- Enrolment
- 186 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medtronic MiniMed, Inc.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Ronald Brazg, MD, Principal investigator, Rainier Clinical Research CenterTimothy Bailey, MD, Principal investigator, AMCR InstituteJeanie Tryggestad, MD, Principal investigator, OUHSC Department of PediatricsLinda DiMeglio, MD, Principal investigator, Indiana University, Riley Hospital for ChildrenLarry Fox, MD, Principal investigator, Nemours Children's ClinicJennifer Sherr, MD, Principal investigator, Yale University, Yale Diabetes Research ProgramRobert Slover, MD, Principal investigator, Barbara Davis CenterEva Tsalikian, MD, Principal investigator, University of Iowa Children Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01991470
- Sponsor's protocol ID
- CEP249
- Status last verified
- Aug 2018
- First submitted
- 18 Nov 2013
- Last updated
- 27 Sep 2018
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Publications
Slover RH, Tryggestad JB, DiMeglio LA, Fox LA, Bode BW, Bailey TS, Brazg R, Christiansen MP, Sherr JL, Tsalikian E, Kaiserman KB, Sullivan A, Huang S, Shin J, Lee SW, Kaufman FR. Accuracy of a Fourth-Generation Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes. Diabetes Technol Ther. 2018 Sep;20(9):576-584. doi: 10.1089/dia.2018.0109. Epub 2018 Jul 31.
PubMed 30063162
Study at a glance
From the registry record, last updated by the sponsor on 27 Sep 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Performance Evaluation of the Enlite™ and Enlite 3 Glucose Sensor to Support Use in Children
- ClinicalTrials.gov ID
- NCT01991470
- Acronym / sponsor ID
- CEP249
- Conditions
- Insulin Requiring Diabetes
- Keywords
- Insulin requiring diabetes, Children, Sensor, Accuracy
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 186 participants (actual)
- Lead sponsor
- Medtronic MiniMed, Inc.Industry (pharma, biotech, devices)
- Study start
- Mar 2015
- Primary completion
- Dec 2016 (actual)
- Study completion
- Dec 2016 (actual)
- First posted
- 25 Nov 2013 (estimated)
- Results
- Posted 27 Sep 2018
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to evaluate the Enlite Sensor™ and Enlite 3 Sensor performance in pediatric patients with insulin requiring diabetes at the beginning, middle and end of sensor wear.
Detailed description
This study is a prospective, single arm, multi-center, in-clinic study.. There will be two consecutive phases of the study:
A total of up to 260 subjects (2-18 years old) will be enrolled at up to 15 investigational centers
Subjects will come for clinic visit for YSI reference glucose testing and for Enlite Sensor™ and Enlite 3 Sensor™ testing. SMBG (Self-Monitoring of Blood Glucose) reference measurement is for subjects 2-6 years of age and cannot tolerate YSI.
Study has a run-in period and a study period with a total of 10 visits
Study design
- Primary purpose
- Treatment
- Intervention model
- Sequential
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Enlite sensors | Experimental | Device: Enlite sensorsEach subject will first wear enlite sensors and will come for clinic visit for YSI (Yellow Spring Instruments). Then each subject will wear enlite 3 sensors and will come for clinic visit for YSI (Yellow Spring Instruments) or SMBG (Self-Monitoring of Blood Glucose) testing. SMBG testings are for subjects 2-6 years of age and cannot tolerate YSI. In addition. In addition, subjects aged 2-6 years old will not participate in Enlite phase. They only participate in Enlite 3 phase. |
Who may qualify
- Ages
- 2 to 18 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult
Key inclusion criteria (6 listed)
- Subject is 2-18 years of age at time of screening
- Subject has been diagnosed with insulin requiring diabetes mellitus for at least one year.
- Subject is willing to perform greater than or equal to 4 finger stick blood glucose measurements daily
- Subject is willing to perform required sensor calibrations
- Subject is willing to wear the system (Guardian Mobile application, pumps, sensors, meter) continuously throughout the study
Key exclusion criteria (5 listed)
- Subject is unable to tolerate tape adhesive in the area of sensor placement
- Subject has any unresolved adverse skin condition in the area of sensor or device placement (e.g., psoriasis, rash, Staphylococcus infection)
- Subject is actively participating in an investigational study (drug or device) wherein they have received treatment from an investigational study (drug or device) in the last 2 weeks
- Females of child-bearing potential who have a positive pregnancy test at screening or plans to become pregnant during the course of the study
- Subjects with hematocrit lower than the normal age specific reference range per central or local lab testing
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Enlite sensorsSubject wears enlite sensor first and followed by enlite 3 sensor. | Device | Enlite sensors |
Primary outcome
Enlite Sensor Accuracy Mean Absolute Relative Difference (MARD), With Lower Serial Number 530G Pump
Time frame: 6 days
Enlite Sensor accuracy relative to the YSI (Yellow Spring Instruments) reference. Each subject wore two 530G pumps. The results for the lower serial number pump worn by each subject were arbitrarily selected and pooled across subjects for the primary dataset. MARD = Mean of ((Absolute difference of YSI reference and Sensor glucose values / YSI reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days were pooled together for reporting purpose.
Enlite 3 Sensor Accuracy Mean Absolute Relative Difference (MARD), With the Guardian Mobile System
Time frame: 7 days
Enlite 3 Sensor accuracy using Guardian Mobile System compared to YSI or SMBG (Self-Monitoring of Blood Glucose) reference values. For subjects 2-6 years of age, SMBG was used as a reference value if YSI cannot be tolerated. MARD = Mean of ((Absolute difference of reference and Sensor glucose values / reference glucose values) * 100). Therefore, the unit of MARD is percentage (%). Note that results from multiple testing days will be pooled together for reporting purpose.
6 secondary outcomes
Enlite 3 Sensor Accuracy Mean Absolute Relative Difference (MARD), With the GST3C Transmitter
Time frame: 7 days
Enlite Sensor Accuracy Mean Absolute Relative Difference (MARD), With Higher Serial Number 530G Pump
Time frame: 6 Days
Enlite Sensor Accuracy Mean Absolute Relative Difference (MARD), With Lower Serial Number 530G Pump, Using One Additional Calibration During FST
Time frame: 6 Days
Enlite Sensor Accuracy Mean Absolute Relative Difference (MARD), With Higher Serial Number 530G Pump, Using One Additional Calibration During FST
Time frame: 6 Days
Enlite 3 Sensor Accuracy Mean Absolute Relative Difference (MARD), With the Guardian Mobile System, Using One Additional Calibration During FST
Time frame: 7 Days
Enlite 3 Sensor Accuracy Mean Absolute Relative Difference (MARD), With GST3C Transmitter, Using One Additional Calibration During FST
Time frame: 7 Days
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 Sep 2018.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Derived from this study: PubMed 30063162Slover RH, Tryggestad JB, DiMeglio LA, Fox LA, Bode BW, Bailey TS, Brazg R, Christiansen MP, Sherr JL, Tsalikian E, Kaiserman KB, Sullivan A, Huang S, Shin J, Lee SW, Kaufman FR. Accuracy of a Fourth-Generation Continuous Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes. Diabetes Technol Ther. 2018 Sep;20(9):576-584. doi: 10.1089/dia.2018.0109. Epub 2018 Jul 31.
Related trials for Insulin Requiring Diabetes
Recruiting
Integrating New Skills Into Diabetes Education With CGM
Insulin Dependent Diabetes, Diabetes (DM)
Recruiting
Evaluation of the Safety and Performance of the Novel Medtronic Experimental Automated Insulin Delivery System (NMX8) in People Living With Diabetes (NEXUS)
Diabetes (Insulin-requiring, Type 1 or Type 2)
RecruitingObservational study
Benefits of Retained Insulin for Good Health
Diabetes (Insulin-requiring, Type 1 or Type 2), Diabetes
Not yet recruiting
A Novel Miniature Equine-Assisted Diabetes Education Program for Youth: Evaluating the Diabetes Equine Empowerment Program (DEEP).
Diabetes (Insulin-requiring, Type 1 or Type 2), Pediatric Diabetes
Recruiting
APP-MNT: App-Enhanced Medical Nutrition Therapy on Glycemic Outcomes and Quality of Life
Diabetes (Insulin-requiring, Type 1 or Type 2)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Ronald Brazg, MD principal investigator
Rainier Clinical Research Center
Timothy Bailey, MD principal investigator
AMCR Institute
Jeanie Tryggestad, MD principal investigator
OUHSC Department of Pediatrics
11 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Enlite sensors in people with Insulin Requiring Diabetes, run by Medtronic MiniMed, Inc. at 11 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 27 Sep 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 11 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 27 Sep 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Enlite Sensor Accuracy Mean Absolute Relative Difference (MARD), With Lower Serial Number 530G Pump (time frame: 6 days). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01991470, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Sep 2018; AzTrials last refreshed its copy on 27 Oct 2026.