AzTrials
AzTrials

Cystic FibrosisNCT01987271

Effects Of Noninvasive Ventilation On Functional Capacity Of Patients With Cystic Fibrosis

A study testing Noninvasive Ventilation in people with Cystic Fibrosis, run by Universidade Federal de Pernambuco at 1 site in Brazil.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this study is to evaluate the effect of noninvasive ventilation (NIV) in functional capacity of children and adolescents with cystic fibrosis. Read more about this study

Who is it for?
Ages 7 to 16 years
Conditions the study is for
Cystic Fibrosis
What is being tested?
Noninvasive Ventilation
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
13 participants
Where
1 siteBrazil
Study dates
Aug 2012to Jan 2013
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 7 to 16 years
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • clinical diagnosis of Cystic Fibrosis
  • FEV1< 80% of predicted
  • age between 7 and 16 years
  • clinically stable patients
  • no history of hospitalization for respiratory failure in the last three months

Who cannot join

  • recent history of hemoptysis
  • pneumothorax or evidence of emphysomatous bubbles detected by chest X-ray
  • Burkholderia cepacia colonization
  • the need for more than two physiotherapy sessions per day
  • gastroesophageal reflux
  • orthopedic trauma or cardiovascular conditions that impede the treadmill walk test
  • heart failure

Trial locations and contacts

1 site in 1 country.

Brazil1 site
  • Instituto de Medicina Intergral Prof. Fernando Fiqueira

    Recife, Pernambuco, 50070-550

Other trials in Brazil

About this study

Official title: Effects Of Noninvasive Ventilation During The Treadmill Walking Test On Cardiorespiratory System, Walk Distance, And Thoracoabdominal Kinematics Of Patients With Cystic Fibrosis: Clinical Randomized Controlled Trial.

The purpose of this study is to evaluate the effect of noninvasive ventilation (NIV) in functional capacity of children and adolescents with cystic fibrosis.

Read the detailed description

This is an open randomized controlled crossover clinical trial. Sample selection was by convenience and patients were screened at the Pneumology outpatient facility of the Instituto de Medicina Integral Professor Fernando Figueira (IMIP) in Recife, Brazil.

The sample was calculated using a software developed by the MGH Mallinckrodt General Clinical Research Center, based on the results of the first 10 volunteers, for a statistical power of detecting differences between procedures of 80% and a significance level of 0.05. A sample size of n=13 patients was determined, considering that the real difference between the walk distance between procedures with and without NIV is 0.03 km and the standard deviation of the differences in variables is 0.034 km.

All patients agreed to take part in the study by giving their informed consent, in accordance with resolution 196/96 of the National Health Council.

Technical Procedures Patients were initially assessed for current and past conditions, medication use and anthropometric data (height, weight and body mass index - BMI). Next, a randomized plan was compiled using the Web Site Randomization.com, applying a generator of random-permuted blocks to define the order in which patients would execute the 6MWT, with or without NIV. Patients allocated to group 1 (G1) initiated the 6MWT without NIV to subsequently perform the test with ventilatory support, since those allocated to group 2 (G2) underwent the tests in reverse order. A minimum and maximum rest period of 24 and 48 hours, respectively, was observed between tests.

Before and after the 6MWT with and without NIV, patients were assessed for variations in compartmental chest wall volume and ventilatory pattern by optoelectronic plethysmography (OEP), which was followed by the spirometric test. A 20-minute rest period was given after the pulmonary function test before proceeding to the 6MWT.

6-minute walk test on the treadmill: Prior to the test, the patient was familiarized with the treadmill (G-635, Pro Action BH-fitness- Germany) and instructed about test procedures in accordance with ATS guidelines22. The following parameters were assessed before, immediately after and in the 5th minute post-test: blood pressure (BP), respiratory rate (RR), heart rate (HR), Borg's scale (BS) and peripheral O2 saturation (SpO2). HR, RR and SpO2 were also monitored minute by minute during the test, such that a drop in SpO2 below 87% or rise in RR to more than 75% of age-predicted maximal HR were used as criteria for interrupting the test. The test initiated with the treadmill traveling at 2.5 km/h. Every 30 seconds of the test, the examiner asked the patient if the speed could be increased, maintained or decreased, and patients answered using previously agreed upon signals. The speed could not exceed 7 km/h and if it was reached, the question would be re-asked in the next 30 seconds to determine whether the speed would be maintained or reduced. After the test, the walk distance (WD) on the treadmill was recorded.

The 6MWT performed with NIV followed the same procedures described above. However, before the test, patients were submitted to NIV on a BiPAP mode (Synchrony- Respironics, Brazil) for 30 minutes, as proposed by Serra et al 15, with inspiratory airway pressure (IPAP) level of 12 cmH2O and final expiratory airway pressure (EPAP) of 6 cmH2O, which can vary by 2 cmH2O more or less depending on the patient's comfort. In the last six minutes of BiPAP the patient performed the 6MWT with the ventilatory support.

Optoelectronic plethysmography: The individual was sitting with 89 retro-reflective sensors at specific thoracic and abdominal points. Eight cameras were arranged around the patient for a three-minute film of quiet breathing. The images were analyzed in a three-dimensional polyhedric model using OEP capture software (BTS Bioengineering, Italy). The following variables were assessed by OEP (BTS Bioengineering, Italy) before and after both tests, with and without NIV: tidal volume, pulmonary rib cage volume, abdominal rib cage and abdominal volume (VC, Vrcp Vrca, Vab), respiratory rate (RR), inspiratory time (Ti), expiratory time (Te) total ventilatory cycle time (Ttot) and duty cycle, which represents the Ti/Ttot ratio.

Spirometry: Spirometry was conducted using a Microloop MK 8 spirometer (Micro Medical, England) to assess pulmonary function response, considering a 20-minute rest period between the spirometric test and 6MWT. Three reproducible forced maneuvers that met American Thoracic Society criteria were performed. The highest values obtained for forced expiratory volume in the first minute (FEV1), forced vital capacity (FVC), forced vital capacity between 25-75% of FVC (FEF 25-75) were recorded for analysis.

Conditions
Cystic Fibrosis
Being tested
Noninvasive Ventilation
Keywords
exercise tolerance, exercise test, noninvasive ventilation
Medical subject headings
Cystic Fibrosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Noninvasive VentilationDevice

    Also called BiLEVEL, Noninvasive ventilatory support

    A randomized plan define the order in which patients would execute the 6MWT, with or without NIV.

Study groups in NCT01987271
Study groupRoleWhat they receive
With noninvasive ventilationExperimentalWhen patients do the six minute walk test with the noninvasive ventilation.
Receives: Device: Noninvasive Ventilation
Without noninvasive ventilationNo interventionWhen patients do the six minute walk test without noninvasive ventilation.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Walk Distance (WD) on six minute walk test (6MWT)

    Patients allocated to group 1 (G1) initiated the 6MWT without noninvasive ventilation (NIV) to subsequently perform the test with ventilatory support, since those allocated to group 2 (G2) underwent the tests in reverse order. Rest period between tests: 24 - 48 hours. At the end of the test, the walk distance on a treadmill is recorded.

    Measured: 2 days

Secondary outcomes (5)
  1. Forced expiratory volume in the first second (FEV1)

    The patients do the walk test a twice on a week. Before and after each test, this variable is recorded.

    Measured: 2 days

  2. Rib cage volumes

    This variable is assessed by Optoeletronic Pletismography (BTS Bioengineering, Italy) before and after both tests, with and without NIV, recording the tidal volume, pulmonary rib cage volume, abdominal rib cage and abdominal volume (Vt, Vrcp Vrca, Vab).

    Measured: 2 days

  3. Forced vital capacity (FVC)

    The patients do the walk test a twice on the same week. Before and after each test, this variable is recorded.

    Measured: 2 days

  4. Forced expiratory flow of 25% to 75% of FVC (FEF 25-75)

    The patients do the walk test a twice on the same week. Before and after each test, this variable is recorded.

    Measured: 2 days

  5. Respiratory cicle time

    This following variable is assessed by Optoeletronic Pletismography (BTS Bioengineering, Italy) before and after both tests, with and without NIV, recording the respiratory rate (RR), inspiratory time (Ti), expiratory time (Te), total ventilatory cycle time (Ttot) and duty cycle, which represents the Ti/Ttot ratio.

    Measured: 2 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Nov 2013 (estimated)
  2. Study startAug 2012
  3. Primary completionJan 2013
  4. Study completionJan 2013

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
13 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01987271
Sponsor's protocol ID
0.381.0.172.099-11
Status last verified
Nov 2013
First submitted
4 Nov 2013
Last updated
19 Nov 2013
Results posted
No
Data monitoring committee
Yes

Publications

  • Engelsbel S, Kuijper EJ, Dankert J, Braat MC, Egas J. [A tuberculosis project in Ecuador]. Ned Tijdschr Geneeskd. 1991 Dec 21;135(51):2428-32. Dutch.

    PubMed 1758504
  • Aliverti A, Cala SJ, Duranti R, Ferrigno G, Kenyon CM, Pedotti A, Scano G, Sliwinski P, Macklem PT, Yan S. Human respiratory muscle actions and control during exercise. J Appl Physiol (1985). 1997 Oct;83(4):1256-69. doi: 10.1152/jappl.1997.83.4.1256.

    PubMed 9338435

Questions about this trial

What is this clinical trial studying?

A study testing Noninvasive Ventilation in people with Cystic Fibrosis, run by Universidade Federal de Pernambuco at 1 site in Brazil.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Nov 2013. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Walk Distance (WD) on six minute walk test (6MWT) (time frame: 2 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01987271, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Nov 2013.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in