ArrhythmiaNCT01913561

The Use of Master Caution Garment for Continuous Monitoring for Arrhythmia Detection

A study testing Master Caution Garment and ECG gel electrodes in people with Arrhythmia, run by HealthWatch Ltd. at 1 site in Israel.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The Master Caution Garment is embedded with 10/13 textile dry electrodes that enable 12/15-lead ECG. The electrodes are dry, textile ECG electrodes. The garment is designed to position the electrodes in the appropriate anatomical locations, without any special guidance. Read more about this study

Who is it for?
Ages 18 to 90 years
Conditions the study is for
Arrhythmia
What is being tested?
Master Caution Garment and ECG gel electrodes
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
16 participants
Where
1 siteIsrael
Study dates
Sep 2013to 31 Aug 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age>18 years.
  • Suspected for arrhythmia or have evidence of arrhythmia disorder.
  • Needs continuous, in-hospital ECG monitoring.
  • Ability to give informed consent.

Who cannot join

  • Patients with known allergy to silver.
  • Patients with recent trauma to chest wall.
  • Pregnant or lactating woman.
  • Patients with chest deformity precluding placement of the garment.
  • Patients participating in another ongoing trial.

Trial locations and contacts

1 site in 1 country.

Israel1 site
  • Rambam medical center

    Haifa, 9602

Other trials in Israel

About this study

Official title: The Use of Master Caution Garment for Continuous Monitoring for Arrhythmia Detection Compared To Standard Gel-Electrode-Based ECG

The Master Caution Garment is embedded with 10/13 textile dry electrodes that enable 12/15-lead ECG.

The electrodes are dry, textile ECG electrodes. The garment is designed to position the electrodes in the appropriate anatomical locations, without any special guidance. The dry electrodes are made from unique yarns with silver embedded into the garment using a proprietary technique developed by HealthWatch (HW)that obviates the need for skin preparation or the application of fluids. The garment can be connected to any standard ECG device available in the hospitals.

Read more

The purpose of this study is to evaluate the safety and effectiveness of the Master Caution Garment for continuous monitoring of ECG signal compared to standard gel electrodes.

The following endpoints will be evaluated in subjects participating in the study:

Primary:

Compare the quality of the ECG signal of HW textile electrodes compared to gel electrodes using standard ECG devices.

Secondary:

Compare the quality of the ECG signal of HW textile electrodes compared to gel electrodes when event is detected by the ECG devices.

Read the detailed description

Part A - ECG in Rest

  1. In the beginning of the study, the following parameters will be measured and documented in the CRF: blood pressure, body temperature, respiratory rate and oxygen saturation in the blood.
  2. The patient will be dressed with the Master Caution Garment and connected to a 12 lead ECG device. The procedure takes 5 minutes including data printing.
  3. A twelve lead ECG with gel electrodes will be done and data printed. The procedure takes 5 minutes. The patient will stay connected to the monitor for the following hour.
  4. After an hour the data from the gel electrodes will be printed again.
  5. The patient will be dressed again with the Master Caution Garment and connected to a 12 lead ECG device. The procedure takes 5 minutes including data printing.
  6. The following parameters will be compared between the gel ECG and the Garment ECG:
  • Heart Rate (HR)
  • P wave width and amplitude
  • QRS complex width and amplitude
  • T wave width and amplitude
  • RR interval
  • PR interval
  • QT interval

Part B - ECG in motion

  1. In the beginning of the study, the following parameters will be measured : blood pressure, body temperature, respiratory rate and oxygen saturation in the blood.
  2. Four (4) gel electrodes will be placed on the patient on the following places - Left Arm (LA), Right Arm (RA), Left Leg (LL) and Right Leg (RL).
  3. The patient will be dressed with the Master Caution Garment (MCG)on the 4 gel electrodes that were already placed.
  4. The same 4 electrodes in the garment LA, RA, LL and RL will be connected to a standard of care ECG device.
  5. The 4 gel electrodes will be connected to a standard of care ECG device.
  6. The ECG devices will be recording the ECG signal from the two sets of electrodes for 24 hours. Every hour in the first 6 hours the data will be printed from both devices. In every event detected the data will be printed from both devices. the data will be evaluated for quality comparison between the gel and the textile electrodes using the hospital ECG device.
  7. In first 6 hours for every hour and for each event detected by either the gel electrodes or the MCG textile electrodes the following parameters shell be evaluated at the end of the study from the hospital ECG printouts for the Master Caution Garment and for the gel electrodes:
  • Heart Rate (HR)
  • P wave width and amplitude
  • QRS complex width and amplitude
  • T wave width and amplitude
  • RR interval
  • PR interval
  • QT interval After first 6 hours for each event detected by either the gel electrodes or the MCG textile electrodes the above mentioned parameters shell be evaluated at the end of the study from the hospital ECG printouts for the Master Caution Garment and for the gel electrodes.

The goal of the current study is to evaluate the safety of the MCG and compare ECG signals from the Master Caution Garment with the ECG signals from gel electrodes.

This is a prospective, comparative study.

For each time interval and each event detected by the ECG devices, the analysis will determine its category as follows:

  1. Blinded cardiologist's assessment whether at that time interval the patient suffered from a disorder. This assessment will be based on hospital's recorded data with the gel electrodes.
  2. The Master Caution Garment result for that time interval will be categorized as follows:
  • True Positive (TP) = MCG Alert was right (based on GS)
  • False Positive (FP) = MCG Alert was wrong
  • True Negative (TN) = No MCG Alert when indeed alert was not necessary
  • False Negative (FN) = No MCG Alert but there was a disorder case
Conditions
Arrhythmia
Being tested
Master Caution Garment, ECG gel electrodes
Keywords
Electrocardiogram, gel electrodes, textile electrodes
Medical subject headings
Arrhythmias, Cardiac

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Master Caution GarmentDevice

    Also called MCG

    Master Caution Garment is embedded with 10/13 textile dry electrodes that enable 12/15-lead ECG.

    The electrodes are dry, textile ECG electrodes.

  • ECG gel electrodesDevice

    Standard gel electrodes that are been in use in hospital for ECG monitoring.

Study groups in NCT01913561
Study groupRoleWhat they receive
Master Caution GarmentExperimentaleach patient will be connected simultaneously with two devices: * ECG gel electrodes * Master Caution Garment textile electrodes The two devices will be connected to hospital ECG telemetry.
Receives: Device: Master Caution Garment; Device: ECG gel electrodes

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. From the ECG record collect the Heart Rate HR.

    Measured: 0,1,2,3,4,5,6 hours and in each arrythemia event detected durring 24 hours from the start of the ECG recording.

  2. From the ECG record collect the P Wave width (sec.) and the amplitude (mV).

    Measured: 0,1,2,3,4,5,6 hours and in each arrythemia event detected durring 24 hours from the start of the ECG recording.

  3. From the ECG record collect the QRS Complex width (sec.) and the amplitude (mV).

    Measured: 0,1,2,3,4,5,6 hours and in each arrythemia event detected durring 24 hours from the start of the ECG recording.

  4. From the ECG record collect the T Wave width (sec.) and the amplitude (mV).

    Measured: 0,1,2,3,4,5,6 hours and in each arrythemia event detected durring 24 hours from the start of the ECG recording.

  5. From the ECG record collect the RR Interval width (sec.).

    Measured: 0,1,2,3,4,5,6 hours and in each arrythemia event detected durring 24 hours from the start of the ECG recording.

  6. From the ECG record collect the PR Interval width (sec.).

    Measured: 0,1,2,3,4,5,6 hours and in each arrythemia event detected durring 24 hours from the start of the ECG recording.

  7. From the ECG record collect the QT Interval width (sec.).

    Measured: 0,1,2,3,4,5,6 hours and in each arrythemia event detected durring 24 hours from the start of the ECG recording.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Aug 2013 (estimated)
  2. Study startSep 2013
  3. Primary completionJun 2017
  4. Study completion31 Aug 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
16 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01913561
Sponsor's protocol ID
HWG001
Status last verified
Aug 2018
First submitted
24 Jul 2013
Last updated
8 Aug 2018
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Master Caution Garment and ECG gel electrodes in people with Arrhythmia, run by HealthWatch Ltd. at 1 site in Israel.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 8 Aug 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Israel. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

From the ECG record collect the Heart Rate HR. (time frame: 0,1,2,3,4,5,6 hours and in each arrythemia event detected durring 24 hours from the start of the ECG recording.). The study lists 7 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Aug 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in