Trial summary

The overall goal of this proposal is to correlate ultrasound elastography technique with more standard clinically based outcome measures within the setting of a small sample sized group of patients affected by moderate-to- severe, chronic (>6months) midsubstance Achilles tendinopathy (AT). Read more about this study

Who is it for?
Ages 18 to 65 years
Conditions the study is for
Achilles Tendinitis
What is being tested?
Autologous Platelet Rich Plasma, Ultrasound Imaging and Quality of Life Questionnaires
Type of treatment
Injection or infusion
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteUnited States
Study dates
Jun 2013to 10 Jan 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • age 18-65 years, inclusive
  • diagnosis of moderate to severe AT, confirmed by Dr. Wilson using clinical symptoms and exam findings consistent with chronic AT (>6 month duration) - which includes pain while palpating the intratendinous swelling part of the Achilles tendon and relief of pain when tendon placed under tension - and pre-procedure US
  • self-reported AT-related pain for at least 6 months and VAS (Visual Analog Scale) pain >5 (0-10 scale)
  • self-reported failure of eccentric exercise protocol (at least 75% completion)
  • self-reported failure of at least 2 of the 3 most common treatments for AT (NSAIDS, rest/ice or taping)
  • patient considered surgery but decided to wait and/or refused surgery -

Who cannot join

  • bilateral AT
  • insertional AT
  • local steroid injection within 6 weeks or physical therapy within 4 weeks
  • inability to comply with follow-up criteria
  • history of surgery on the Achilles tendon or systemic diseases (general inflammatory diseases such as rheumatologic disorders and diabetes)
  • daily use of opioids for pain
Show all 9Show fewer
  • anticoagulation or immunosuppressive therapy
  • intent to use NSAIDs or steroids
  • self-reported pregnancy

Trial locations and contacts

1 site in 1 country.

United States1 site
  • University of Wisconsin, Madison

    Madison, Wisconsin, 53705

Other trials in United States

About this study

Official title: A Pilot Study Correlating Novel Ultrasound Elastography Techniques to Standard Clinical Outcomes in the Treatment of Achilles Tendinopathy With Platelet-Rich Plasma Therapy

The overall goal of this proposal is to correlate ultrasound elastography technique with more standard clinically based outcome measures within the setting of a small sample sized group of patients affected by moderate-to- severe, chronic (>6months) midsubstance Achilles tendinopathy (AT).

Read the detailed description

The main goal for this pilot level study is to correlate ultrasound elastography technique with more standard clinically based outcome measures within the setting of a small sample sized group of patients affected by moderate-to- severe, chronic (> 6 months) midsubstance Achilles tendinopathy (AT). Investigators will conduct a 24-week, 2-arm randomized controlled pilot study to determine whether novel elastography techniques (AE) and shear wave imaging (SWI), a new quantitative method of ultrasound (US) imaging, correlate with valid clinical outcome measures (VISA-A and conventional US). Methods will be based on recently published clinical trials of autologous blood injections for treating AT and will incorporate novel US outcome measures of Achilles tendon appearance and stiffness, i.e. elasticity. The results of this multi-disciplinary pilot study will be used to help plan a separate larger scaled study to evaluate the effects of platelet-rich plasma (PRP) therapy for Achilles tendinopathy in which elastography will be included as a potential outcome measure and also correlated with standard clinical outcome surveys.

Pain and function will be evaluated by self-report using a validated clinical outcome questionnaire (VISA-A). Disease modification will be assessed by novel US-based AE and SWI methods for stiffness changes (biomechanical) and correlated with morphologic changes using conventional US. A larger study that will evaluate the effects of PRP in healing AT, while correlating with elastography assessment, will include a sham injection arm.

Intervention Subjects assigned to the PRP group will then receive the PRP injection under ultrasound guidance. The injection will take about 15 minutes.

Each subject will undergo a palpatory and ultrasound Achilles tendon exam. Tender areas associated with the Achilles tendon will be identified. Physical exam will be followed by Achilles tendon ultrasound which will serve as visual guidance for injection.

At the injection session, the research nurse will perform a single standard antecubital blood draw (35 mL). The PRP will be obtained from this sample using a two-stage spinning technique: the 1st separates red blood cells from platelets, and the 2nd concentrates the platelets to yield approximately 4 mL of concentrated autologous platelet. This layer of platelet rich plasma will be placed in the syringe by the centrifuge machine.

Platelet counts of subjects' whole blood and PRP processed blood will be analyzed. Platelet counts in whole blood vary by individual. The optimal quantity of platelets and growth factors required for tissue healing is not known, but a clinically effective concentration has been described as being greater than 4 times baseline autologous whole blood platelet concentrations. Therefore, platelet concentration yield may have important implications in clinical outcome correlation. In order to validate consistent platelet concentration yields across subjects, investigators will sample 1 mL of whole blood (approximately one lab Vacutainer) and an additional 1 mL of platelet rich plasma for lab analysis of platelet concentration using a standard lab automated analyzer. This extra 1 ml of whole blood will be drawn at the same time that the 35 ml described above is drawn.

The 3 ml of platelet rich plasma will be injected into the subject's Achilles tendon. The specimens will not be kept or stored. The blood will be analyzed on the same day as the procedure is being performed. This will not require storing of the specimen and prevent erroneous labeling of platelet concentration with a different subject.

After the injections, the subject will rest for 5 minutes. Participants will be given acetaminophen for "as-needed" analgesia and will be telephoned after 3 days to inquire about side effects or adverse events. Subjects will be placed in a boot for two weeks with gradual return to activity. Subjects will also be provided crutches to be non-weight bearing for 24 hours.

Data and Safety Monitoring Plan The data and safety monitoring plan to be implemented in this study consists, in part, of a monthly staff meeting to discuss subject enrollment, safety, and retention. These meetings are intended to monitor participant study flow from initial eligibility assessment to study completion. Standing agenda items for these meetings will be side effects, adverse events and participant retention.

Unanticipated adverse events and complications will be evaluated and treated if necessary by the Principal Investigator and the primary Co-Investigator.

In addition, the following processes will help ensure the timely detection, evaluation and treatment:

  1. The Principal Investigator and the primary Co-Investigator will screen subjects for adverse events prior to treatment with PRP. Standardized forms will be used for monitoring and reporting of adverse events. The PI will be immediately available to staff via cell phone in case of a serious adverse event. The PI will immediately report serious adverse events to the UW Research Subjects Advocate using standardized forms. Reports will be made using the subject identification number without other identifying information.
  2. Autologous injection of PRP has been found to be safe. The system being used was chosen for its closed system to prevent contamination and for its ease of use. Although safe, internal monitoring of PRP injection safety will also be performed. The study coordinator will assess each PRP injection subject 3 days after treatment with the following question during a brief telephone interview: "Do you think that you have had any side effects from the injection you've received?" [If "Yes"] "Please tell me more about that." Information regarding side effects and adverse events will be made available to the PI, who will decide if the subject requires further medical care.

Investigators do not expect serious adverse events (SAEs) but are well equipped to manage them. Investigators have not seen significant adverse events in combined (UW Radiology and Sports Medicine) clinic use of PRP. Subjects with reactions to acetaminophen or injections have the option to call study personnel at any time. The PI and the primary Co-Investigator will share on-call duty for subjects with adverse events through a pager on a 24/7 basis. Subjects who require significant evaluation and care will be referred to the UW Hospital Emergency Department.

Adverse events from a diagnostic ultrasound are extremely unlikely because ultrasound is considered to have non-significant risk by the FDA. All study procedures will be monitored and documented, and in the unlikely situation where an adverse event occurs, it will be followed to resolution.

The PI(a Board-Certified radiologist) will assess whether the findings should be reported to subjects. Findings that would be reported are those considered clinically relevant. Findings that are considered normal variants (eg. variant anatomy) or clinically insignificant (eg. simple hepatic cyst) will not be reported. Clinically relevant findings will be reported to the subject within 24 hours of the scan, and will also be reported to the subject's physician according to whether the subject has indicated a desire for this in the consent form.

Being tested
Autologous Platelet Rich Plasma, Ultrasound Imaging, Quality of Life Questionnaires
Keywords
Achilles, tendinopathy
Medical subject headings
Tendinopathy

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Autologous Platelet Rich PlasmaOther

    This procedure will include a single collection of 35 mL of peripheral blood. A two-stage spinning protocol will be used: the 1st separates red blood cells from platelets, and the 2nd concentrates the platelets to yield approximately 4 mL of concentrated autologous platelet. This layer of platelet rich plasma will be placed in the syringe by the centrifuge machine.

  • Ultrasound ImagingOther

    A conventional ultrasound in addition to AE and shear wave imaging (SWI) will be administered.

  • Quality of Life QuestionnairesOther

    Also called Victorian Institute of Sports Assessment - Achilles (VISA-A)

    This questionnaire is a self-report of pain and function associated with the Achilles tendon.

Study groups in NCT01911650
Study groupRoleWhat they receive
Autologous Platlet Rich PlasmaExperimentalThis subject arm will receive one injection of autologous platelet rich plasma for the treatment of Achilles tendinopathy. In addition, they will be asked to undergo a palpatory exam of the Achilles tendon; complete Quality of Life Questionnaires at three different time points; and complete a 30 minute ultrasound imaging exam of the Achilles tendon.
Receives: Other: Autologous Platelet Rich Plasma; Other: Ultrasound Imaging; Other: Quality of Life Questionnaires
WaitlistOtherSubjects in this arm will have already received standard of care interventions for Achilles tendinopathy with unsatisfactory outcomes. For this research they will be asked to undergo a palpatory exam of the Achilles tendon; complete Quality of Life Questionnaires at three different time points; and complete a 30 minute ultrasound imaging exam of the Achilles tendon.
Receives: Other: Ultrasound Imaging; Other: Quality of Life Questionnaires

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Structure and Biomechanical function

    Primary outcome measure: Estimate ultrasound based changes consistent with disease modification in two ways:

    1. conventional ultrasound to assess Achilles tendon thickness, neovascularity, and hypoechogenicity.
    2. estimate AE and SWI variability and the correlations of AE and SWI with conventional ultrasound measures to plan future research.

    Measured: 12 weeks

Secondary outcomes (1)
  1. Quality of Life Assessment

    Secondary outcome measure: Quality of life will be assessed with the VISA-A validated questionnaire of pain and function of the Achilles tendon. This measure will be administered at three time points.

    Measured: 12 weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted30 Jul 2013 (estimated)
  2. Study startJun 2013
  3. Primary completion10 Jan 2019
  4. Study completion10 Jan 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01911650
Sponsor's protocol ID
2012-0908
Status last verified
Jan 2019
First submitted
23 Jul 2013
Last updated
18 Jan 2019
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing Autologous Platelet Rich Plasma, Ultrasound Imaging and Quality of Life Questionnaires in people with Achilles Tendinitis, run by University of Wisconsin, Madison at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 Jan 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Structure and Biomechanical function (time frame: 12 weeks). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 Jan 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in