Gastrointestinal HemorrhageNCT01853241
Prospective Randomized Trial of Anterograde Single Balloon Versus Spirus Enteroscopy
An observational study of Gastrointestinal Hemorrhage and Inflammatory Bowel Disease, run by Johns Hopkins University at 1 site in United States.
Trial summary
The small bowel is poorly suited to standard endoscopy techniques due to its anatomical differences from the colon and the upper gastrointestinal tract. The small bowel has an average length of 6.7 m, with a free mesentery that resists standard "push to advance" endoscopy techniques. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Gastrointestinal Hemorrhage, Inflammatory Bowel Disease, Gastrointestinal Neoplasms
- What is being tested?
- Single Balloon and Spirus
- Type of treatment
- Surgery or procedure
- How many people
- 30 participants
- Where
- 1 siteUnited States
- Study dates
- May 2010to Jan 2011
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients referred to our center for anterograde augmented enteroscopy for the assessment of suspected small disease
Who may be able to join
- Age >18 years old
- Referred to Johns Hopkins Hospital for anterograde augmented enteroscopy to assess for small bowel disease
Who cannot join
- Patients who are unable to give informed consent
- Women who are pregnant
- Inability to tolerate sedated endoscopy due to cardio-pulmonary instability or other contraindication to endoscopy
- Patients who require retrograde enteroscopy as determined by the principle investigator
- Patients with altered small bowel anatomy (i.e. Roux-en-Y anastomosis, Bilroth II anatomy)
- Cirrhosis
- Esophageal stricture
- Uncorrected coagulopathy
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Prospective Randomized Trial of Anterograde Single Balloon Versus Spirus Enteroscopy in Patients With Suspected Small Bowel Disease
The small bowel is poorly suited to standard endoscopy techniques due to its anatomical differences from the colon and the upper gastrointestinal tract. The small bowel has an average length of 6.7 m, with a free mesentery that resists standard "push to advance" endoscopy techniques. New developments in overtubes, which are placed over an enteroscope, have revolutionized doctors ability to deeply intubate the small bowel. Three types of 'augmented' enteroscopy, double balloon enteroscopy (DBE), single balloon enteroscopy (SBE) and spiral enteroscopy (SE), have been developed. Although studies have been performed on these individual techniques, there are no studies comparing SBE and SE, the two techniques used in Johns Hopkins.
The investigators propose performing a prospective, randomised trial, to assess the differences between these two techniques. The question of what differences there are between these two techniques, in terms of depth of insertion, diagnostic and therapeutic yields, time required for the procedure and the sedation requirements, are important questions to answer, and depending on the results, would affect the investigators approach to patients with small bowel disease.
Read the detailed description
We currently perform both spiral enteroscopy (SE) and single balloon enteroscopy (SBE) in Johns Hopkins Hospital. The decision as to which procedure to use is determined by the endoscopist performing the procedure, with currently approximately 60% being performed with SE and 40% performed with SBE. We wish to perform a prospective, randomised trial, to assess the differences between these two procedures. The question of what differences there are between these two techniques, in terms of depth of insertion, diagnostic and therapeutic yields, time required for the procedure and the sedation requirements, are important questions to answer, and depending on the results, would affect the investigators approach to patients with small bowel disease.
The small bowel is poorly suited to standard endoscopy techniques due to its anatomical differences from the colon and the upper gastrointestinal tract. The small bowel has an average length of 6.7 m, with a free mesentery that resists standard "push to advance" endoscopy techniques. New developments in overtubes, which are placed over an enteroscope, have revolutionized the investigators ability to deeply intubate the small bowel. The first of these new techniques to be described was double balloon enteroscopy (DBE) (Fujinon, Wayne, NJ) in 2001. The next development was single balloon enteroscopy (SBE) (Olympus America, Center Valley PA), an iteration of DBE that simply forgoes the second balloon at the tip of the endoscope, and also allows for deep enteroscopy which has been available in the United States since 2007. Spiral enteroscopy (SE) was introduced soon after SBE in 2007, and consists of a spiral overtube (Spirus Medical Inc., Stoughton, Massachusetts, USA) which pleats the small bowel onto the enteroscope.
DBE has the largest amount of published data, with more than 1370 patients and 2591 examinations. Data regarding the efficacy of SBE and SE are more limited than DBE. SBE and SE have only been available in the United States since 2007, and therefore have less published data than DBE. There are two published series of SBE, with several more publications in abstract form. A total of 362 cases have been reported, with diagnostic yields ranging between 30% to 76%, with therapeutic intervention performed in up to 55%. There are 6 reports of SE procedures, with one large series of 1750 cases documenting side effects of SE. The overall diagnostic yield ranged from 24% to 51% with similar treatment success rates. SBE has been compared with DBE in patients with suspected small bowel disease in three studies reported in abstract form. SE has been compared with push enteroscopy and DBE, however there have been no studies comparing SBE and SE.
The risks associated with augmented enteroscopy (DBE, SBE, SE) are similar to those associated with routine endoscopy and include sedation-related complications, aspiration pneumonia, and respiratory infections. In addition, there have been complications specifically related to augmented enteroscopy. Abdominal discomfort can occur due to trapped gas. DBE has been associated with intestinal cramping in 2% to 20% of patients. The use of CO2, which the investigators routinely use in Johns Hopkins, decreases post procedure abdominal cramping. Minor small bowel contusion can occur. The incidence of gastrointestinal haemorrhage does not seem to be increased in augmented enteroscopy compared with standard endoscopic procedures. Pancreatitis occurred in 6 (0.2%) of cases reported in a multicenter United States study of DBE. There have been no reports of pancreatitis associated with SBE or SE enteroscopy. Intestinal perforation is a rare but serious event. Perforation has been reported in 5 (0.2%) of 2591 DBE examinations. In SBE, one perforation was reported in a series of 37 patients, with a case report of a perforation in a patients with jejuna ulceration from metastatic adenocarcinoma of unknown primary. A mucosal tear, requiring endoscopic clip esophageal or gastric perforation, severe bleeding requiring transfusion, cardio-pulmonary arrests or deaths. There were 7 (0.4%) severe complications. Six were small bowel perforations (0.34%).
In Johns Hopkins there has been one perforation using SBE and one using SE one of which occurred in a patient with small bowel Crohns disease (SBE) and the other in a patient with altered anatomy (SE) (personal communication Dr PI Okolo). This latter group of patients are known to be at increased risk of perforation during endoscopic procedures and will be excluded from this study. There have had no other serious complication associated with either SE or SBE enteroscopy. All of the individuals who will participate in this study are already scheduled to have an augmented enteroscopy. Therefore, there is no additional risk incurred by the patient by participating in this study, over and above the risk of an augmented enteroscopy which is part of the routine clinical care for these patients.
- Being tested
- Single Balloon, Spirus
- Keywords
- small intestine, endoscopy, gastrointestinal
- Medical subject headings
- Gastrointestinal Hemorrhage, Inflammatory Bowel Diseases, Gastrointestinal Neoplasms
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Single BalloonProcedure or surgery
Also called Single Balloon Enteroscopy
All patients in this group will undergo single balloon enteroscopy
SpirusProcedure or surgery
Also called Spirus Enteroscopy
All patients in this group will undergo Spirus Enteroscopy
| Study group | Role | What they receive |
|---|---|---|
| Single balloon | Single Balloon Enteroscopy Receives: Procedure: Single Balloon | |
| Spirus | Spirus Enteroscopy Receives: Procedure: Spirus |
What is being measured
The primary outcome is the main question the study is designed to answer.
Comparison of the depth of insertion into the small bowel of SBE compared with SE from the pylorus.
The depth of insertion was defined as the maximum distance the enteroscope was inserted past the pylorus. In SBE, the endoscopist estimates in 10cm increments from 0 to 40 cm the length of small bowel released during each insertion of the overtube and pulling back of the enteroscope and overtube. The net advancement is defined as the DMI for SBE. For SE the DMI is calculated by counting the length of bowel examined in 10-cm increments upon withdrawal of the enteroscope and overtube.
Measured: At the time of procedure
Secondary outcomes (4)
Comparison of the complication rate between the two techniques.
Patients were contacted by telephone within 1 week of the procedure. Immediate and short term complications were recorded. Major complications were defined as deep laceration, perforation, significant bleeding requiring blood products, pancreatitis, or hospital admission related to the procedure. Minor complications were defined as mild to moderate mucosal trauma (score 1-3), sore throat less than 72 hours in duration, abdominal discomfort lasting less than 48 hours in duration, or mild nausea or vomiting.
Mucosal trauma was evaluated upon withdrawal of the enteroscope. Pain was assessed on a 10 point visual analogue scale before and after the procedure. Patients underwent a telephone interview within 7 days of the procedure where the type and severity of side effects and complications were assessed
Measured: 7 days of procedure
Comparison of the diagnostic yield between the two techniques.
Diagnostic yield was defined as the number of patients who had a diagnosis confirmed with enteroscopy.
Measured: immediate
Comparison of the therapeutic yield between the two techniques.
Therapeutic yield was defined as the number of patients who required a intervention at the time of enteroscopy
Measured: immediate
A comparison of the mean adjusted diagnostic procedure time
This is calculated by for all procedures: total time minus therapy time.
Measured: immediate
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 May 2013 (estimated)
- Study startMay 2010
- Primary completionJan 2011
- Study completionJan 2011
Why it stopped: SE system by Spirus Medical withdrawn from market in 2011
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (9)Papers the sponsor has linked to this study.
- Other trials for Gastrointestinal HemorrhageStudies of the same condition, open and under way.
- More trials run by Johns Hopkins UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 30 participants (actual)
Sponsor and investigators
- Lead sponsor
- Johns Hopkins University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Patrick Okolo, MD, Johns Hopkins University
- Investigators
- Patrick Okolo, MD, Principal investigator, Johns Hopkins University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01853241
- Sponsor's protocol ID
- NA_00031000JHU
- Other IDs
- NA_00031000
- Status last verified
- May 2013
- First submitted
- 10 May 2013
- Last updated
- 14 May 2013
- Results posted
- No
- Data monitoring committee
- No
Publications
Hartmann D, Eickhoff A, Tamm R, Riemann JF. Balloon-assisted enteroscopy using a single-balloon technique. Endoscopy. 2007 Feb;39 Suppl 1:E276. doi: 10.1055/s-2007-966616. Epub 2007 Oct 24. No abstract available.
PubMed 17957636Akerman PA, Agrawal D, Cantero D, Pangtay J. Spiral enteroscopy with the new DSB overtube: a novel technique for deep peroral small-bowel intubation. Endoscopy. 2008 Dec;40(12):974-8. doi: 10.1055/s-0028-1103402. Epub 2008 Dec 8.
PubMed 19065477Tsujikawa T, Saitoh Y, Andoh A, Imaeda H, Hata K, Minematsu H, Senoh K, Hayafuji K, Ogawa A, Nakahara T, Sasaki M, Fujiyama Y. Novel single-balloon enteroscopy for diagnosis and treatment of the small intestine: preliminary experiences. Endoscopy. 2008 Jan;40(1):11-5. doi: 10.1055/s-2007-966976. Epub 2007 Dec 4.
PubMed 18058613Kawamura T, Yasuda K, Tanaka K, Uno K, Ueda M, Sanada K, Nakajima M. Clinical evaluation of a newly developed single-balloon enteroscope. Gastrointest Endosc. 2008 Dec;68(6):1112-6. doi: 10.1016/j.gie.2008.03.1063. Epub 2008 Jul 2.
PubMed 18599052Akerman PA, Cantero D. Spiral enteroscopy and push enteroscopy. Gastrointest Endosc Clin N Am. 2009 Jul;19(3):357-69. doi: 10.1016/j.giec.2009.04.001.
PubMed 19647645Mehdizadeh S, Ross A, Gerson L, Leighton J, Chen A, Schembre D, Chen G, Semrad C, Kamal A, Harrison EM, Binmoeller K, Waxman I, Kozarek R, Lo SK. What is the learning curve associated with double-balloon enteroscopy? Technical details and early experience in 6 U.S. tertiary care centers. Gastrointest Endosc. 2006 Nov;64(5):740-50. doi: 10.1016/j.gie.2006.05.022.
PubMed 17055868Heine GD, Hadithi M, Groenen MJ, Kuipers EJ, Jacobs MA, Mulder CJ. Double-balloon enteroscopy: indications, diagnostic yield, and complications in a series of 275 patients with suspected small-bowel disease. Endoscopy. 2006 Jan;38(1):42-8. doi: 10.1055/s-2005-921188.
PubMed 16429354Gerson LB. Outcomes associated with deep enteroscopy. Gastrointest Endosc Clin N Am. 2009 Jul;19(3):481-96. doi: 10.1016/j.giec.2009.04.007.
PubMed 19647653Vincent JR. [The "Mobile Dental Health Clinic of the South-West" (2)]. J Dent Que. 1991 Jul-Aug;28:341-7. French.
PubMed 1960245
Study at a glance
From the registry record, last updated by the sponsor on 14 May 2013. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Prospective Randomized Trial of Anterograde Single Balloon Versus Spirus Enteroscopy in Patients With Suspected Small Bowel Disease
- ClinicalTrials.gov ID
- NCT01853241
- Acronym / sponsor ID
- NA_00031000JHU
- Keywords
- small intestine, endoscopy, gastrointestinal
- Study type
- Observational
- Recruitment status
- TerminatedReason stopped: SE system by Spirus Medical withdrawn from market in 2011
- Enrolment
- 30 participants (actual)
- Lead sponsor
- Johns Hopkins UniversityUniversity, hospital or other
- Study start
- May 2010
- Primary completion
- Jan 2011 (actual)
- Study completion
- Jan 2011 (actual)
- First posted
- 14 May 2013 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The small bowel is poorly suited to standard endoscopy techniques due to its anatomical differences from the colon and the upper gastrointestinal tract. The small bowel has an average length of 6.7 m, with a free mesentery that resists standard "push to advance" endoscopy techniques. New developments in overtubes, which are placed over an enteroscope, have revolutionized doctors ability to deeply intubate the small bowel. Three types of 'augmented' enteroscopy, double balloon enteroscopy (DBE), single balloon enteroscopy (SBE) and spiral enteroscopy (SE), have been developed. Although studies have been performed on these individual techniques, there are no studies comparing SBE and SE, the two techniques used in Johns Hopkins.
The investigators propose performing a prospective, randomised trial, to assess the differences between these two techniques. The question of what differences there are between these two techniques, in terms of depth of insertion, diagnostic and therapeutic yields, time required for the procedure and the sedation requirements, are important questions to answer, and depending on the results, would affect the investigators approach to patients with small bowel disease.
Detailed description
We currently perform both spiral enteroscopy (SE) and single balloon enteroscopy (SBE) in Johns Hopkins Hospital. The decision as to which procedure to use is determined by the endoscopist performing the procedure, with currently approximately 60% being performed with SE and 40% performed with SBE. We wish to perform a prospective, randomised trial, to assess the differences between these two procedures. The question of what differences there are between these two techniques, in terms of depth of insertion, diagnostic and therapeutic yields, time required for the procedure and the sedation requirements, are important questions to answer, and depending on the results, would affect the investigators approach to patients with small bowel disease.
The small bowel is poorly suited to standard endoscopy techniques due to its anatomical differences from the colon and the upper gastrointestinal tract. The small bowel has an average length of 6.7 m, with a free mesentery that resists standard "push to advance" endoscopy techniques. New developments in overtubes, which are placed over an enteroscope, have revolutionized the investigators ability to deeply intubate the small bowel. The first of these new techniques to be described was double balloon enteroscopy (DBE) (Fujinon, Wayne, NJ) in 2001. The next development was single balloon enteroscopy (SBE) (Olympus America, Center Valley PA), an iteration of DBE that simply forgoes the second balloon at the tip of the endoscope, and also allows for deep enteroscopy which has been available in the United States since 2007. Spiral enteroscopy (SE) was introduced soon after SBE in 2007, and consists of a spiral overtube (Spirus Medical Inc., Stoughton, Massachusetts, USA) which pleats the small bowel onto the enteroscope.
DBE has the largest amount of published data, with more than 1370 patients and 2591 examinations. Data regarding the efficacy of SBE and SE are more limited than DBE. SBE and SE have only been available in the United States since 2007, and therefore have less published data than DBE. There are two published series of SBE, with several more publications in abstract form. A total of 362 cases have been reported, with diagnostic yields ranging between 30% to 76%, with therapeutic intervention performed in up to 55%. There are 6 reports of SE procedures, with one large series of 1750 cases documenting side effects of SE. The overall diagnostic yield ranged from 24% to 51% with similar treatment success rates. SBE has been compared with DBE in patients with suspected small bowel disease in three studies reported in abstract form. SE has been compared with push enteroscopy and DBE, however there have been no studies comparing SBE and SE.
The risks associated with augmented enteroscopy (DBE, SBE, SE) are similar to those associated with routine endoscopy and include sedation-related complications, aspiration pneumonia, and respiratory infections. In addition, there have been complications specifically related to augmented enteroscopy. Abdominal discomfort can occur due to trapped gas. DBE has been associated with intestinal cramping in 2% to 20% of patients. The use of CO2, which the investigators routinely use in Johns Hopkins, decreases post procedure abdominal cramping. Minor small bowel contusion can occur. The incidence of gastrointestinal haemorrhage does not seem to be increased in augmented enteroscopy compared with standard endoscopic procedures. Pancreatitis occurred in 6 (0.2%) of cases reported in a multicenter United States study of DBE. There have been no reports of pancreatitis associated with SBE or SE enteroscopy. Intestinal perforation is a rare but serious event. Perforation has been reported in 5 (0.2%) of 2591 DBE examinations. In SBE, one perforation was reported in a series of 37 patients, with a case report of a perforation in a patients with jejuna ulceration from metastatic adenocarcinoma of unknown primary. A mucosal tear, requiring endoscopic clip esophageal or gastric perforation, severe bleeding requiring transfusion, cardio-pulmonary arrests or deaths. There were 7 (0.4%) severe complications. Six were small bowel perforations (0.34%).
In Johns Hopkins there has been one perforation using SBE and one using SE one of which occurred in a patient with small bowel Crohns disease (SBE) and the other in a patient with altered anatomy (SE) (personal communication Dr PI Okolo). This latter group of patients are known to be at increased risk of perforation during endoscopic procedures and will be excluded from this study. There have had no other serious complication associated with either SE or SBE enteroscopy. All of the individuals who will participate in this study are already scheduled to have an augmented enteroscopy. Therefore, there is no additional risk incurred by the patient by participating in this study, over and above the risk of an augmented enteroscopy which is part of the routine clinical care for these patients.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Single balloon | – | Procedure: Single BalloonSingle Balloon Enteroscopy |
| Spirus | – | Procedure: SpirusSpirus Enteroscopy |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients referred to our center for anterograde augmented enteroscopy for the assessment of suspected small disease
Key inclusion criteria (2 listed)
- Age >18 years old
- Referred to Johns Hopkins Hospital for anterograde augmented enteroscopy to assess for small bowel disease
Key exclusion criteria (8 listed)
- Patients who are unable to give informed consent
- Women who are pregnant
- Inability to tolerate sedated endoscopy due to cardio-pulmonary instability or other contraindication to endoscopy
- Patients who require retrograde enteroscopy as determined by the principle investigator
- Patients with altered small bowel anatomy (i.e. Roux-en-Y anastomosis, Bilroth II anatomy)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Single BalloonAlso: Single Balloon EnteroscopyAll patients in this group will undergo single balloon enteroscopy | Procedure or surgery | Single balloon |
| SpirusAlso: Spirus EnteroscopyAll patients in this group will undergo Spirus Enteroscopy | Procedure or surgery | Spirus |
Primary outcome
Comparison of the depth of insertion into the small bowel of SBE compared with SE from the pylorus.
Time frame: At the time of procedure
The depth of insertion was defined as the maximum distance the enteroscope was inserted past the pylorus. In SBE, the endoscopist estimates in 10cm increments from 0 to 40 cm the length of small bowel released during each insertion of the overtube and pulling back of the enteroscope and overtube. The net advancement is defined as the DMI for SBE. For SE the DMI is calculated by counting the length of bowel examined in 10-cm increments upon withdrawal of the enteroscope and overtube.
4 secondary outcomes
Comparison of the complication rate between the two techniques.
Time frame: 7 days of procedure
Comparison of the diagnostic yield between the two techniques.
Time frame: immediate
Comparison of the therapeutic yield between the two techniques.
Time frame: immediate
A comparison of the mean adjusted diagnostic procedure time
Time frame: immediate
Results and safety
The study was stopped early (reason given: SE system by Spirus Medical withdrawn from market in 2011). Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 14 May 2013.
- Background: PubMed 17957636Hartmann D, Eickhoff A, Tamm R, Riemann JF. Balloon-assisted enteroscopy using a single-balloon technique. Endoscopy. 2007 Feb;39 Suppl 1:E276. doi: 10.1055/s-2007-966616. Epub 2007 Oct 24. No abstract available.
- Background: PubMed 19065477Akerman PA, Agrawal D, Cantero D, Pangtay J. Spiral enteroscopy with the new DSB overtube: a novel technique for deep peroral small-bowel intubation. Endoscopy. 2008 Dec;40(12):974-8. doi: 10.1055/s-0028-1103402. Epub 2008 Dec 8.
- Background: PubMed 18058613Tsujikawa T, Saitoh Y, Andoh A, Imaeda H, Hata K, Minematsu H, Senoh K, Hayafuji K, Ogawa A, Nakahara T, Sasaki M, Fujiyama Y. Novel single-balloon enteroscopy for diagnosis and treatment of the small intestine: preliminary experiences. Endoscopy. 2008 Jan;40(1):11-5. doi: 10.1055/s-2007-966976. Epub 2007 Dec 4.
- Background: PubMed 18599052Kawamura T, Yasuda K, Tanaka K, Uno K, Ueda M, Sanada K, Nakajima M. Clinical evaluation of a newly developed single-balloon enteroscope. Gastrointest Endosc. 2008 Dec;68(6):1112-6. doi: 10.1016/j.gie.2008.03.1063. Epub 2008 Jul 2.
- Background: PubMed 19647645Akerman PA, Cantero D. Spiral enteroscopy and push enteroscopy. Gastrointest Endosc Clin N Am. 2009 Jul;19(3):357-69. doi: 10.1016/j.giec.2009.04.001.
- Background: PubMed 17055868Mehdizadeh S, Ross A, Gerson L, Leighton J, Chen A, Schembre D, Chen G, Semrad C, Kamal A, Harrison EM, Binmoeller K, Waxman I, Kozarek R, Lo SK. What is the learning curve associated with double-balloon enteroscopy? Technical details and early experience in 6 U.S. tertiary care centers. Gastrointest Endosc. 2006 Nov;64(5):740-50. doi: 10.1016/j.gie.2006.05.022.
- Background: PubMed 16429354Heine GD, Hadithi M, Groenen MJ, Kuipers EJ, Jacobs MA, Mulder CJ. Double-balloon enteroscopy: indications, diagnostic yield, and complications in a series of 275 patients with suspected small-bowel disease. Endoscopy. 2006 Jan;38(1):42-8. doi: 10.1055/s-2005-921188.
- Background: PubMed 19647653Gerson LB. Outcomes associated with deep enteroscopy. Gastrointest Endosc Clin N Am. 2009 Jul;19(3):481-96. doi: 10.1016/j.giec.2009.04.007.
- Background: PubMed 1960245Vincent JR. [The "Mobile Dental Health Clinic of the South-West" (2)]. J Dent Que. 1991 Jul-Aug;28:341-7. French.
Related trials for Gastrointestinal Hemorrhage
Recruiting
Prospective, Multicenter, Randomized Controlled Phase III Trial of Biological Mesh for Alimentary Tract Reconstruction in Digestive Surgery
Digestive System Surgical Procedures, Anastomosis, Surgical
RecruitingObservational study
Treatment Outcomes and Predictors After Endovascular Intervention for Portal Hypertension-Related Gastrointestinal Bleeding in Cirrhosis
Cirrhosis, Portal Hypertension Related to Cirrhosis
Active, not recruitingObservational study
Resumption of Anticoagulation After Major Gastrointestinal Bleeding in Patients With Atrial Fibrillation
Atrial Fibrillation (AF), Major Gastrointestinal Bleeding (MGIB)
RecruitingPhase 2
Fecal Microbiota Transplantation for Radiation-Induced Proctopathy
Radiation Induced Proctitis
Recruiting
OTSC vs. Angiographic Embolization in Patients With Refractory Non-variceal Upper Gastrointestinal Bleeding
Upper Gastrointestinal Bleeding
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Patrick Okolo, MD principal investigator
Johns Hopkins University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Gastrointestinal Hemorrhage and Inflammatory Bowel Disease, run by Johns Hopkins University at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: stopped early, as of the sponsor's last update on 14 May 2013. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was stopped early (reason given: SE system by Spirus Medical withdrawn from market in 2011). Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Comparison of the depth of insertion into the small bowel of SBE compared with SE from the pylorus. (time frame: At the time of procedure). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01853241, which also lists 9 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 May 2013.