AstigmatismNCT01852084
Hydrophobic Acrylic Toric IOL Designed to Reduce the Effects of Preoperative Corneal Astigmatism
A study testing enVista® One-Piece Hydrophobic Acrylic Toric IOL in people with Astigmatism, run by Bausch & Lomb Incorporated at 1 site in United States.
Trial summary
The investigational enVista IOL, Model MX60Tis equipped with toric optics and axis marks on the posterior surface to minimize the possibility of surgically induced astigmatism. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Astigmatism
- What is being tested?
- enVista® One-Piece Hydrophobic Acrylic Toric IOL
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 191 participants
- Where
- 1 siteUnited States
- Study dates
- 6 Mar 2013to Dec 2016
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subjects must have a clinically significant cataract in the study eye that is considered amenable to treatment with standard phacoemulsification cataract extraction.
- Subjects must require a lens power from 16.0 D to 27.0 D in the study eye.
- Subjects must be willing to discontinue contact lens wear for the duration of the study and, demonstrate stability prior to biometry and surgery in the study eye.
- Subjects must have a best corrected distance visual acuity (BCDVA) projected to be better than 20/30 after toric IOL implantation in the study eye.
- Subjects must have predicted postoperative corneal astigmatism between 0.90D and 2.40D in the study eye, as determined by the Toric Calculator.
- Subjects must have a minimum preoperative corneal astigmatism of 0.90 D in the study eye.
- Subjects must have a dilated preoperative pupil size greater than or equal to 5.0 mm in the study eye.
Who cannot join
- Subjects who have had previous intraocular or corneal surgery in the study eye.
- Subjects with any clinically significant ocular pathology which would be expected to reduce potential BCDVA to 20/30 or worse in the study eye during the course of the study.
- Subjects with any anterior segment pathology in the study eye likely to increase the risk of complications from phacoemulsification cataract surgery.
- Subjects with associated ocular conditions which could affect the stability of the IOL in the study eye.
- Subjects with a traumatic cataract in the study eye.
- Subjects with uncontrolled glaucoma in the study eye.
Show all 12Show fewer
- Subjects with clinically significant irregular corneal astigmatism in the study eye, as determined by the medical judgment of the Investigator.
- Subjects with clinically significant corneal pathology potentially affecting topography of either eye.
- Subjects with any ocular condition that could prevent the possibility of a visual outcome better than 20/30 in the study eye.
- Subjects with a difference of greater than 0.50D of corneal astigmatism as measured with the IOL Master and the topographer in the study eye using vector analysis.
- Subjects with an anterior chamber depth <2mm in the study eye.
- Subjects with potential BCDVA of 20/200 or worse in the fellow eye.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: To Evaluate the Safety and Effectiveness of the EnVista® One-Piece Hydrophobic Acrylic Toric IOL Designed to Reduce the Effects of Preoperative Corneal Astigmatism on Postoperative Refraction Following Cataract Surgery
The investigational enVista IOL, Model MX60Tis equipped with toric optics and axis marks on the posterior surface to minimize the possibility of surgically induced astigmatism.
Read the detailed description
The investigational enVista Toric IOL, Model MX60T, and the currently approved Model MX60, are identical with the exception of the addition of toric optics and axis marks on the posterior optic surface for the correction of astigmatism on the Model MX60T. Both lenses have an aspheric biconvex optic with a modified C haptic monoblock, single-piece design. The design and material of both the MX60 and MX60T allow them to be folded and inserted through small incisions to minimize the possibility of surgically induced astigmatism (SIA).
- Conditions
- Astigmatism
- Being tested
- enVista® One-Piece Hydrophobic Acrylic Toric IOL, enVista control lens
- Medical subject headings
- Astigmatism
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
enVista® One-Piece Hydrophobic Acrylic Toric IOLDevice
Test lens having a toric cylinder power of either 1.25 diopters (D), 2.00 D, or 2.75 D
enVista control lensDevice
Spherical Control lens
| Study group | Role | What they receive |
|---|---|---|
| enVista® One-Piece Hydrophobic Acrylic Toric IOL | Experimental | Toric cylinder power of either 1.25 diopters (D), 2.00 D, or 2.75 D Receives: Device: enVista® One-Piece Hydrophobic Acrylic Toric IOL |
| enVista control lens | Experimental | Spherical control lens Receives: Device: enVista control lens |
What is being measured
The primary outcome is the main question the study is designed to answer.
Mean Dioptric Change in Cylinder
Dioptric change in cylinder from the preoperative keratometric cylinder magnitude to postoperative manifest refraction cylinder magnitude (referenced to the corneal plane).
Measured: Baseline, Final Visit (scheduled within window: days 120-180)
Percentage of Participants With Intraocular Lens (IOL) Rotation of Less Than or Equal to Five Degrees
Intraocular Lens (IOL) rotation of less than or equal to five degrees between Forms 3 (scheduled within window: days 30-60) and final visit (scheduled within window: days 120-180).
Measured: Form 3 Visit (window: days 30-60), Final Visit (window: days 120-180)
Mean Best-corrected Distance Visual Acuity (BCDVA) at Final Visit
Best-corrected distance visual acuity (BCDVA) at Final Visit, expressed as logarithm of the minimum angle of resolution (logMAR). Corrected means spectacle corrected. Visual acuity (VA) was reported as letters read correctly, and the letters read were converted to logarithm of the minimum angle of resolution (logMAR) acuity. The participant read rows of letters on a standard LogMAR chart until the participant misses 3 letters on a row with 5 letters. The total number of correct letters were recorded. A decrease in the number of correct letters indicates a decrease in visual acuity.
Measured: Final Visit (scheduled within window: days 120-180)
Percentage of Participants With Reduction in Cylinder Within 0.50 Diopter (D) and Within 1.00 D of Intended.
Measured: Final Visit (scheduled within window: days 120-180)
Secondary outcomes (1)
Mean Uncorrected Distance Visual Acuity (UCDVA) at Final Visit
Uncorrected distance visual acuity (UCDVA), expressed as logarithm of the minimum angle of resolution (logMAR). Uncorrected means not spectacle-corrected. Visual acuity (VA) was reported as letters read correctly, and the letters read were converted to logarithm of the minimum angle of resolution (logMAR) acuity. The participant read rows of letters on a standard LogMAR chart until the participant misses 3 letters on a row with 5 letters. The total number of correct letters were recorded. A decrease in the number of correct letters indicates a decrease in visual acuity.
Measured: Final Visit (scheduled within window: days 120-180)
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 May 2013 (estimated)
- Study start6 Mar 2013
- Primary completion18 Jul 2016
- Study completionDec 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for AstigmatismStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- A Prospective, Multicenter Clinical Trial to Evaluate the Safety and Effectiveness
- Masking
- Double blind
- Who is masked
- Participant, Investigator
- Enrolment
- 191 participants (actual)
Sponsor and investigators
- Lead sponsor
- Bausch & Lomb Incorporated
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Mark Packer, MD, Study director, Bausch & Lomb Incorporated
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01852084
- Sponsor's protocol ID
- 761
- Status last verified
- Aug 2020
- First submitted
- 9 May 2013
- Last updated
- 16 Sep 2020
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- Individual data sharing
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 16 Sep 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- To Evaluate the Safety and Effectiveness of the EnVista® One-Piece Hydrophobic Acrylic Toric IOL Designed to Reduce the Effects of Preoperative Corneal Astigmatism on Postoperative Refraction Following Cataract Surgery
- ClinicalTrials.gov ID
- NCT01852084
- Acronym / sponsor ID
- 761
- Conditions
- Astigmatism
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 191 participants (actual)
- Lead sponsor
- Bausch & Lomb IncorporatedIndustry (pharma, biotech, devices)
- Study start
- 6 Mar 2013 (actual)
- Primary completion
- 18 Jul 2016 (actual)
- Study completion
- Dec 2016 (actual)
- First posted
- 13 May 2013 (estimated)
- Results
- Posted 16 Sep 2020
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The investigational enVista IOL, Model MX60Tis equipped with toric optics and axis marks on the posterior surface to minimize the possibility of surgically induced astigmatism.
Detailed description
The investigational enVista Toric IOL, Model MX60T, and the currently approved Model MX60, are identical with the exception of the addition of toric optics and axis marks on the posterior optic surface for the correction of astigmatism on the Model MX60T. Both lenses have an aspheric biconvex optic with a modified C haptic monoblock, single-piece design. The design and material of both the MX60 and MX60T allow them to be folded and inserted through small incisions to minimize the possibility of surgically induced astigmatism (SIA).
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, investigator)
- Number of arms
- 2
- Model description
- A Prospective, Multicenter Clinical Trial to Evaluate the Safety and Effectiveness
| Arm | Type | Receives |
|---|---|---|
| enVista® One-Piece Hydrophobic Acrylic Toric IOL | Experimental | Device: enVista® One-Piece Hydrophobic Acrylic Toric IOLToric cylinder power of either 1.25 diopters (D), 2.00 D, or 2.75 D |
| enVista control lens | Experimental | Device: enVista control lensSpherical control lens |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (7 listed)
- Subjects must have a clinically significant cataract in the study eye that is considered amenable to treatment with standard phacoemulsification cataract extraction.
- Subjects must require a lens power from 16.0 D to 27.0 D in the study eye.
- Subjects must be willing to discontinue contact lens wear for the duration of the study and, demonstrate stability prior to biometry and surgery in the study eye.
- Subjects must have a best corrected distance visual acuity (BCDVA) projected to be better than 20/30 after toric IOL implantation in the study eye.
- Subjects must have predicted postoperative corneal astigmatism between 0.90D and 2.40D in the study eye, as determined by the Toric Calculator.
Key exclusion criteria (12 listed)
- Subjects who have had previous intraocular or corneal surgery in the study eye.
- Subjects with any clinically significant ocular pathology which would be expected to reduce potential BCDVA to 20/30 or worse in the study eye during the course of the study.
- Subjects with any anterior segment pathology in the study eye likely to increase the risk of complications from phacoemulsification cataract surgery.
- Subjects with associated ocular conditions which could affect the stability of the IOL in the study eye.
- Subjects with a traumatic cataract in the study eye.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| enVista® One-Piece Hydrophobic Acrylic Toric IOLTest lens having a toric cylinder power of either 1.25 diopters (D), 2.00 D, or 2.75 D | Device | enVista® One-Piece Hydrophobic Acrylic Toric IOL |
| enVista control lensSpherical Control lens | Device | enVista control lens |
Primary outcome
Mean Dioptric Change in Cylinder
Time frame: Baseline, Final Visit (scheduled within window: days 120-180)
Dioptric change in cylinder from the preoperative keratometric cylinder magnitude to postoperative manifest refraction cylinder magnitude (referenced to the corneal plane).
Percentage of Participants With Intraocular Lens (IOL) Rotation of Less Than or Equal to Five Degrees
Time frame: Form 3 Visit (window: days 30-60), Final Visit (window: days 120-180)
Intraocular Lens (IOL) rotation of less than or equal to five degrees between Forms 3 (scheduled within window: days 30-60) and final visit (scheduled within window: days 120-180).
Mean Best-corrected Distance Visual Acuity (BCDVA) at Final Visit
Time frame: Final Visit (scheduled within window: days 120-180)
Best-corrected distance visual acuity (BCDVA) at Final Visit, expressed as logarithm of the minimum angle of resolution (logMAR). Corrected means spectacle corrected. Visual acuity (VA) was reported as letters read correctly, and the letters read were converted to logarithm of the minimum angle of resolution (logMAR) acuity. The participant read rows of letters on a standard LogMAR chart until the participant misses 3 letters on a row with 5 letters. The total number of correct letters were recorded. A decrease in the number of correct letters indicates a decrease in visual acuity.
Percentage of Participants With Reduction in Cylinder Within 0.50 Diopter (D) and Within 1.00 D of Intended.
Time frame: Final Visit (scheduled within window: days 120-180)
1 secondary outcome
Mean Uncorrected Distance Visual Acuity (UCDVA) at Final Visit
Time frame: Final Visit (scheduled within window: days 120-180)
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 16 Sep 2020.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: Yes
Related trials for Astigmatism
Not yet recruiting
Clinical Performance and Outcomes After Toric Lens Transition
Astigmatism
Not yet recruiting
The EYERISING Study
Myopia, Astigmatism
Active, not recruiting
P1 Toric Vs. Max 1day
Eye, Astigmatism
Recruiting
Evaluation of Two Monthly Silicone Hydrogel Multifocal Toric in Soft Contact Lens Wearers
Astigmatism, Myopia
Recruiting
Clareon TruPlus Study
Aphakia, Astigmatism
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Mark Packer, MD study director
Bausch & Lomb Incorporated
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing enVista® One-Piece Hydrophobic Acrylic Toric IOL in people with Astigmatism, run by Bausch & Lomb Incorporated at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 7 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 16 Sep 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 16 Sep 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Mean Dioptric Change in Cylinder (time frame: Baseline, Final Visit (scheduled within window: days 120-180)). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.