Hernia, HiatalPhase 3GIANTNCT01780285
Laparoscopic Repair of Giant Hiatal Hernias With Nitinol-framed Lightweight Polytetrafluoroethylene Mesh
A Phase 3 study testing Nitinol-framed lightweight PTFE mesh for hiatal repair and Partially absorbable lightweight mesh for hiatal repair in people with Hernia, Hiatal, run by Odessa National Medical University at 1 site in Ukraine.
Trial summary
This study is prospective randomized trial enrolling at least 50 participants which compares efficacy and safety of two alternative methods of laparoscopic hiatal repair for giant (i.e. Read more about this study
- Who is it for?
- Ages 20 to 80 years
- Conditions the study is for
- Hernia, Hiatal
- What is being tested?
- Nitinol-framed lightweight PTFE mesh for hiatal repair and Partially absorbable lightweight mesh for hiatal repair
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 50 participants
- Where
- 1 siteUkraine
- Study dates
- Jun 2013to Feb 2017
- Phase
- Phase 3
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 20 to 80 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Type II and III hiatal hernias, including complicated by GERD,
- Able to undergo elective laparoscopic hiatal hernia repair,
- Able to 24 months follow-up with office examinations,
- Hiatal surface area (HSA) exceeding 20 sq.cm (by Granderath et al, 2007) which correspond to the diameter of hernia defect exceeding 8 cm (the distinct size is determined intraoperatively, those with smaller diameter will be excluded from the study),
- Nissen fundoplication (intraoperative criterion)
Who cannot join
- Unable to undergo laparoscopic hiatal hernia repair due to: severe comorbidities (ASA III and more), previous major surgery with severe adhesions, etc.
- Cases of conversion to open surgery
- Age < 20 years and > 80 years
- BMI < 16 and > 39 kg/sq.m
- Pregnancy or plans for pregnancy within next 2 years (in females)
- Uncorrectable coagulopathy and immunosuppression
Show all 13Show fewer
- Oesophageal motility disorders
- Oesophageal peptic strictures
- Oesophageal diverticula, other types (i.e. non-reflux) of chronic esophagitis, connective tissue disorders (e.g. scleroderma)
- Oesophageal shortening (determined intraoperatively as inability to achieve intra-abdominal length of oesophagus at least 3 cm in spite of intramediastinal oesophageal mobilization)
- Barrett's oesophagus
- History of oesophageal/gastric/duodenal surgery including vagotomy
- Relapsing course of ulcer disease/hyperacid gastritis including complicated by delayed gastric/duodenal emptying
Trial locations and contacts
1 site in 1 country.
Ukraine1 site
Department of surgery No. 1 of Odessa national medical university, Odessa regional hospital
Odesa, Ukaraine, 65025
About this study
Official title: Prospective Randomized Phase III Study of Laparoscopic Repair of Giant Hiatal Hernias With Nitinol-framed Lightweight Polytetrafluoroethylene Mesh
This study is prospective randomized trial enrolling at least 50 participants which compares efficacy and safety of two alternative methods of laparoscopic hiatal repair for giant (i.e. with hiatal surface area (HSA) exceeding 20 sq.cm) types II and III hiatal hernias: partially absorbable lightweight mesh repair, and nitinol-framed lightweight polytetrafluoroethylene (PTFE) mesh repair. In the literature, mean rate of anatomical recurrence of giant hiatal hernias is 25 %, reaching 42 %. Polypropylene and composite PTFE meshes used most widely, result in unacceptable rates of long-term dysphagia (10-15 %) and oesophageal strictures. Own experience of the interventors of more than 400 repairs using partially absorbable lightweight mesh Ultrapro (Ethicon) and original sub-lay technique of its fixation precluding contact of the mesh with the oesophagus, showed low recurrence rate for large hernias and a few cases of long-term dysphagia. For giant hiatal hernias, this technique provides acceptable results (20 % of recurrence) which correspond to the literature. Nevertheless, these results may be improved, probably by using of new type of prosthesis. Thus, in collaboration with Minnesota Medical Development, Inc., USA, the interventors created fundamentally new method of hiatal repair by using new prosthesis - Rebound HRD-Hiatus hernia. This prosthesis is heart-shaped lightweight PTFE mesh with peripheral nitinol frame. It is easily fixated to the crura posteriorly to the oesophagus completely covering hernia defect, and supports a strong framework of the hiatus, and, therefore, allows to save a principle a real tension-free repair. Mid-term results (mean follow-up period of 15 months) of 29 procedures showed no recurrences or oesophageal complications. Naturally, final conclusions regarding superiority of the new technique could be established by prospective randomized study. The hypothesis of the current trial is: new method of nitinol-framed lightweight PTFE mesh repair is more effective in terms of recurrence rate compared to sub-lay partially absorbable lightweight mesh repair, and is characterized by at least similar safety in terms of oesophageal complications. The long-term results (24 months post surgery for every patient) will be studied using symptom questionnaires, quality of life and satisfaction questionnaires, barium studies, endoscopic examinations, 24-hour pH testing, and analysis of possible reoperations.
Read the detailed description
Giant hiatal hernias, i.e. hernias with hiatal surface area (HSA), as described by Granderath et al (2007), exceeding 20 sq.cm, is one of the most challenging problem in minimally invasive gastrointestinal surgery. On one hand, according to the literature, the rate of utilization of laparoscopic repair of such hernias does not exceed 80 % [Nguyen et al, 2011]. It means that great proportion of patients is still treated using open approach producing 8 % of postoperative complications [Nguyen et al, 2011]. Therefore, improvement of laparoscopic techniques for this disorder is very actual question. On the other hand, the mean rate of anatomical recurrence following laparoscopic repair of paraoesophageal hernias is 25 % as reported in a meta-analysis [Rathore et al, 2007]. It reaches 42 % in some centers according to recent literature reviews [Draaisma et al, 2005; Johnson et al, 2006]. Hence, creation of new method of hiatal repair diminishing recurrence rate is essential. To interventors' opinion, this new method must follow at least a principle of tension-free repair.
As the most concerning problem or repair of giant hiatal hernias is anatomical recurrence, a conception of prosthetic repair was applied for hiatal closure using different types of meshes. This dramatically decreased recurrence rate as demonstrated by several recent studies. Namely, Frantzides et al (2002) prospectively compared primary repair with on-lay PTFE repair and obtained statistically significant decrease of recurrence rate in favor of mesh arm: 0% versus 22%. Then, Granderath et al (2004) compared primary suturing and on-lay polypropylene mesh repair in prospective randomized trial; the rate of recurrence was significantly lower in the mesh arm: 8% versus 26%. Unfortunately, these studies were not primarily addressed to relation between hernia size and results. Most specialists use mesh when the diameter of the defect is just greater than 5 cm, based on own experience and widespread literature data, including studies of Champion et al (1998, 2003). Hiatal surface area (HSA), first described by Granderath et al (2007), is more sensitive measure than diameter of hiatal hernia defect, and further trials should focus on it.
However, SAGES trial reported by Frantzides et al. (2010) showed that polypropylene or PTFE meshes are characterized by the highest incidence of oesophageal complications although they demonstrated relatively lower recurrence rates compared to other meshes. According to most of the literature, mesh-related dysphagia rate is 10-15 % in the long-term follow-up [Granderath et al, 2005, Targarona et al, 2004]. Interestingly, that composite, i.e. partially absorbable meshes, occupied middle position in terms of recurrence and complications rates in this study [Frantzides et al, 2010]. Own experience of the interventors of more than 400 laparoscopic hiatal repairs using lightweight partially absorbable mesh (Ultrapro, Ethicon) showed minimal rate of recurrence (4,9 %) and dysphagia (2,1 %) for large (HSA 10-20 sq.cm) hernias [Grubnik et al, 2011]. The interventors applied this safe technique for giant (HSA > 20 sq.cm) hiatal hernias, but recurrence rate was 20 % [Grubnik et al, 2011]. This result corresponds to the literature, but may be improved. The interventors believe, it is possible to minimize recurrence rate of giant hiatal hernias, but it could be achieved by introduction of fundamentally new types of prostheses and methods of its fixation.
To remove the risk of mesh-related oesophageal complications of polypropylene or PTFE meshes, biological prostheses were introduced for hiatal repair. However, prospective randomized study by Oelschlager et al (2010) demonstrated insignificant difference in recurrence rates in prosthesis arm compared to primary repair arm (more than 50 %), although no cases of mesh-related complications were observed in prosthesis arm. Similar data regarding biological prostheses were retrieved in the study of Frantzides et al (2010). Data from the literature and international congresses suggest that current biological prostheses cannot be widely used in the setting of giant hiatal hernias due to high rate of recurrences and their high price. Thus, based on current literature data, there is insufficient grade 1 evidence for choice of optimal method of repair of giant hiatal hernias, and the search for the optimal prosthesis is still ongoing.
Therefore, a fundamentally new prosthesis for laparoscopic repair of giant hiatal defects was created. The prototype prosthesis "Rebound HRD-Hiatus hernia" was created by the interventors in collaboration with U.S. company, Minnesota Medical Development, Inc. This device is made from high quality lightweight PTFE mesh attached to a heart-shaped nitinol frame with a notch for oesophagus. Prosthesis may be easily inserted through the trocar using a special tube, and expanded to its initial form inside the abdomen. The principle and purpose of using of the device and method of its fixation was patented in Ukraine (patents No. 66397, 66399). The interventors applied new prosthesis in 29 patients, operated from 2010. All procedures were successfully completed. Two main principles are used in a new prosthesis. First, mesh is made of lightweight PTFE minimizing possibility of adhesions and related complications. As a result, there were no esophageal complications in the cohort. Second, peripheral nitinol frame of the prosthesis provides real tension-free repair without risk of prolapse between free, i.e. anterior, margin of the mesh and oesophagus, which other meshes do if fixed to the borders of the hiatus. As a result, there were no recurrences within mean surveillance of 15 months in this series. Naturally, final conclusions regarding superior efficacy and safety of the new device could be established by prospective randomized study.
Therefore, the hypothesis of this double-blind prospective randomized trial is: new method of nitinol-framed lightweight PTFE mesh (Rebound HRD-Hiatus hernia, Minnesota Medical Development, Inc) repair is more effective in terms of recurrence rate compared to sub-lay partially absorbable lightweight mesh (Ultrapro, Ethicon, Inc) repair, and is characterized by at least similar safety in terms of oesophageal complications.
The study will enroll at least 50 patients with giant (HSA > 20 sq.cm) types II and III hiatal hernias. The basic eligibility criteria will be: absence of oesophageal motility disorders, absence of oesophageal shortening requiring Collis procedure, absence of Barrett's oesophagus, peptic strictures and other factors that may independently influence the rate of recurrence and dysphagia/oesophageal strictures. Thus, the only difference between arms will be method of hiatal closure. To exclude fundoplication-related bias, standard floppy-Nissen procedure will be performed in every patient.
Every patient will be operated by single surgical team with an experience of more than 1500 laparoscopic anti-reflux procedures since 1998. The necessary ethic regulations will be saved including informed consent with the statement that patient is unaware of the method of repair (double-masked). Every patient will be evaluated preoperatively, 6 months, and 24 months postoperatively using symptom questionnaires, quality of life and satisfaction questionnaires, barium studies, endoscopic examinations, 24-hour pH testing, and analysis of possible reoperations. For issue of efficacy of prosthetic repair, recurrence rate of hernia and GERD, which are the primary outcome measure, will be studied. For issue of safety of prosthetic repair, rates of long-term dysphagia/oesophageal strictures/mesh erosions, which are main secondary outcome measure, will be evaluated.
- Conditions
- Hernia, Hiatal
- Being tested
- Nitinol-framed lightweight PTFE mesh for hiatal repair, Partially absorbable lightweight mesh for hiatal repair
- Keywords
- Hiatal hernia, Gastro-oesophageal reflux disease, Laparoscopic hiatal repair, Laparoscopic anti-reflux surgery, Partially absorbable lightweight mesh, Polytetrafluoroethylene, PTFE, Nitinol, Nitinol-framed lightweight PTFE mesh
- Medical subject headings
- Hernia, Hiatal, Gastroesophageal Reflux
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Nitinol-framed lightweight PTFE mesh for hiatal repairDevice
Also called Rebound HRD-Hiatus hernia
The heart-shaped nitinol-framed lightweight PTFE prosthesis "Rebound HRD-Hiatus hernia" (Minnesota Medical Development, Inc.) of small (4,0 x 4,5 cm) to large size (5,5 х 6,0 cm) is sutured to the crura posteriorly to oesophagus with 3 or 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures, thus performing complete tension-free hiatal repair.
Partially absorbable lightweight mesh for hiatal repairDevice
Also called Ultrapro
A fashioned according to the dimensions of hernia defect partially absorbable lightweight mesh Ultrapro (Ethicon, Inc.) will be sutured to both crura posteriorly to oesophagus with 3 to 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures (as tension-free repair). Subsequent 2 to 3 interrupted non-absorbable sutures will approximate crura to completely cover a mesh to preclude its contact with the esophagus (original "sandwich" sub-lay technique).
In both arms procedure will be done in a standard fashion: placement of 30 Fr esophageal bougie, reduction of hernia with excision of hernia sac and mobilization of distal esophagus, exposure of borders of hiatal opening, repair of hiatal hernia defect, a short (2,5 - 3,5 cm) 360° fundoplication wrap (floppy-Nissen procedure).
| Study group | Role | What they receive |
|---|---|---|
| Nitinol-framed PTFE mesh hiatal repair | Active comparator | Nitinol-framed lightweight PTFE mesh for hiatal repair Receives: Device: Nitinol-framed lightweight PTFE mesh for hiatal repair |
| Lightweight mesh hiatal repair | Active comparator | Partially absorbable lightweight mesh for hiatal repair Receives: Device: Partially absorbable lightweight mesh for hiatal repair |
What is being measured
The primary outcome is the main question the study is designed to answer.
Anatomical and functional recurrence of hiatal hernia and GERD
Recurrence of hiatal hernia, i.e. anatomical recurrence, will be assessed by symptom questionnaire with visual analogue scales, mainly by barium study, and data from possible redo procedures. Recurrence of GERD, i.e. functional recurrence, will be evaluated by symptom questionnaire with visual analogue scales, endoscopic examination with assessment of degree of reflux-oesophagitis according to Los-Angeles classification, and 24 hour pH-testing with calculation of DeMeester score.
Measured: 24 months
Secondary outcomes (5)
Repair-related dysphagia/oesophageal stricture/prosthetic erosion
Long-term dysphagia, including due to repair-related oesophageal stricture, will be assessed by symptom questionnaire with visual analogue scales, barium study, endoscopic examination, and data from possible redo procedures. Patients also will be endoscopically assessed for such rare complication as prosthetic erosion of oesophagus.
Measured: 24 months
Quality of life and satisfaction
Quality of life and satisfaction will be assessed by GERD-HRQL score
Measured: 24 months
Morbidity
Measured: 1 month
Time to discharge
Time to discharge will be measured in days, from the day of primary surgical procedure, i.e. laparoscopic hiatal hernia repair, to the day of discharge from the hospital
Measured: 1 month
Number of participants completely recovered from extra-oesophageal complications of hiatal hernia following surgical procedure
Extra-oesophageal complications of hiatal hernia to be assessed are: asthma, chronic obstructive pulmonary disease, laryngitis, angina, and arrhythmias
Measured: 24 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted31 Jan 2013 (estimated)
- Study startJun 2013
- Primary completionJan 2015
- Study completionFeb 2017 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (14)Papers the sponsor has linked to this study.
- Other trials for Hernia, HiatalStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 3
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind
- Who is masked
- Participant, Outcomes assessor
- Enrolment
- 50 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Odessa National Medical University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Dr. Andriy V. Malynovskyy, Odessa National Medical University
- Investigators
- Volodymyr V. Grubnik, Prof., MD, Principal investigator, Department of surgery No. 1 of Odessa national medical university
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01780285
- Sponsor's protocol ID
- ONMU-2
- Acronym
- GIANT
- Status last verified
- Jun 2016
- First submitted
- 26 Jan 2013
- Last updated
- 30 Jun 2016
- Results posted
- No
- Data monitoring committee
- No
Publications
Draaisma WA, Gooszen HG, Tournoij E, Broeders IA. Controversies in paraesophageal hernia repair: a review of literature. Surg Endosc. 2005 Oct;19(10):1300-8. doi: 10.1007/s00464-004-2275-3. Epub 2005 Aug 4.
PubMed 16151684Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP. A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg. 2002 Jun;137(6):649-52. doi: 10.1001/archsurg.137.6.649.
PubMed 12049534Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R. Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg. 2005 Jan;140(1):40-8. doi: 10.1001/archsurg.140.1.40.
PubMed 15655204Grubnik VV, Malinovskii AV. [Analysis of long-term results of laparoscopic repair of hiatal hernias and Nissen fundoplication]. Klin Khir. 2012 Oct;(10):34-6. No abstract available. Russian.
PubMed 23272622Oelschlager BK, Pellegrini CA, Hunter JG, Brunt ML, Soper NJ, Sheppard BC, Polissar NL, Neradilek MB, Mitsumori LM, Rohrmann CA, Swanstrom LL. Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. J Am Coll Surg. 2011 Oct;213(4):461-8. doi: 10.1016/j.jamcollsurg.2011.05.017. Epub 2011 Jun 29.
PubMed 21715189Champion JK, McKernan JB. Hiatal size and risk of recurrence after laparoscopic fundoplication [abstract]. Surg Endosc. 1998; 12:565-570.
Champion JK, Rock D. Laparoscopic mesh cruroplasty for large paraesophageal hernias. Surg Endosc. 2003 Apr;17(4):551-3. doi: 10.1007/s00464-002-8817-7. Epub 2003 Feb 17.
PubMed 12582773Frantzides CT, Carlson MA, Loizides S, Papafili A, Luu M, Roberts J, Zeni T, Frantzides A. Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc. 2010 May;24(5):1017-24. doi: 10.1007/s00464-009-0718-6. Epub 2009 Dec 8.
PubMed 19997755Granderath FA, Schweiger UM, Pointner R. Laparoscopic antireflux surgery: tailoring the hiatal closure to the size of hiatal surface area. Surg Endosc. 2007 Apr;21(4):542-8. doi: 10.1007/s00464-006-9041-7. Epub 2006 Nov 14.
PubMed 17103275Johnson JM, Carbonell AM, Carmody BJ, Jamal MK, Maher JW, Kellum JM, DeMaria EJ. Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplications: a critical analysis of the available literature. Surg Endosc. 2006 Mar;20(3):362-6. doi: 10.1007/s00464-005-0357-5. Epub 2006 Jan 25.
PubMed 16437267Nguyen NT, Christie C, Masoomi H, Matin T, Laugenour K, Hohmann S. Utilization and outcomes of laparoscopic versus open paraesophageal hernia repair. Am Surg. 2011 Oct;77(10):1353-7.
PubMed 22127087Rathore MA, Andrabi SI, Bhatti MI, Najfi SM, McMurray A. Metaanalysis of recurrence after laparoscopic repair of paraesophageal hernia. JSLS. 2007 Oct-Dec;11(4):456-60.
PubMed 18237510Targarona EM, Bendahan G, Balague C, Garriga J, Trias M. Mesh in the hiatus: a controversial issue. Arch Surg. 2004 Dec;139(12):1286-96; discussion 1296. doi: 10.1001/archsurg.139.12.1286.
PubMed 15611451Grubnik VV, Malynovskyy AV. Laparoscopic repair of hiatal hernias: new classification supported by long-term results. Surg Endosc. 2013 Nov;27(11):4337-46. doi: 10.1007/s00464-013-3069-2. Epub 2013 Jul 23.
PubMed 23877759
Study at a glance
From the registry record, last updated by the sponsor on 30 Jun 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Prospective Randomized Phase III Study of Laparoscopic Repair of Giant Hiatal Hernias With Nitinol-framed Lightweight Polytetrafluoroethylene Mesh
- ClinicalTrials.gov ID
- NCT01780285
- Acronym / sponsor ID
- GIANT / ONMU-2
- Conditions
- Hernia, Hiatal
- Keywords
- Hiatal hernia, Gastro-oesophageal reflux disease, Laparoscopic hiatal repair, Laparoscopic anti-reflux surgery, Partially absorbable lightweight mesh, Polytetrafluoroethylene, PTFE, Nitinol
- Phase
- Phase 3
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 50 participants (estimated)
- Lead sponsor
- Odessa National Medical UniversityUniversity, hospital or other
- Study start
- Jun 2013
- Primary completion
- Jan 2015 (actual)
- Study completion
- Feb 2017 (estimated)
- First posted
- 31 Jan 2013 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is prospective randomized trial enrolling at least 50 participants which compares efficacy and safety of two alternative methods of laparoscopic hiatal repair for giant (i.e. with hiatal surface area (HSA) exceeding 20 sq.cm) types II and III hiatal hernias: partially absorbable lightweight mesh repair, and nitinol-framed lightweight polytetrafluoroethylene (PTFE) mesh repair. In the literature, mean rate of anatomical recurrence of giant hiatal hernias is 25 %, reaching 42 %. Polypropylene and composite PTFE meshes used most widely, result in unacceptable rates of long-term dysphagia (10-15 %) and oesophageal strictures. Own experience of the interventors of more than 400 repairs using partially absorbable lightweight mesh Ultrapro (Ethicon) and original sub-lay technique of its fixation precluding contact of the mesh with the oesophagus, showed low recurrence rate for large hernias and a few cases of long-term dysphagia. For giant hiatal hernias, this technique provides acceptable results (20 % of recurrence) which correspond to the literature. Nevertheless, these results may be improved, probably by using of new type of prosthesis. Thus, in collaboration with Minnesota Medical Development, Inc., USA, the interventors created fundamentally new method of hiatal repair by using new prosthesis - Rebound HRD-Hiatus hernia. This prosthesis is heart-shaped lightweight PTFE mesh with peripheral nitinol frame. It is easily fixated to the crura posteriorly to the oesophagus completely covering hernia defect, and supports a strong framework of the hiatus, and, therefore, allows to save a principle a real tension-free repair. Mid-term results (mean follow-up period of 15 months) of 29 procedures showed no recurrences or oesophageal complications. Naturally, final conclusions regarding superiority of the new technique could be established by prospective randomized study. The hypothesis of the current trial is: new method of nitinol-framed lightweight PTFE mesh repair is more effective in terms of recurrence rate compared to sub-lay partially absorbable lightweight mesh repair, and is characterized by at least similar safety in terms of oesophageal complications. The long-term results (24 months post surgery for every patient) will be studied using symptom questionnaires, quality of life and satisfaction questionnaires, barium studies, endoscopic examinations, 24-hour pH testing, and analysis of possible reoperations.
Detailed description
Giant hiatal hernias, i.e. hernias with hiatal surface area (HSA), as described by Granderath et al (2007), exceeding 20 sq.cm, is one of the most challenging problem in minimally invasive gastrointestinal surgery. On one hand, according to the literature, the rate of utilization of laparoscopic repair of such hernias does not exceed 80 % [Nguyen et al, 2011]. It means that great proportion of patients is still treated using open approach producing 8 % of postoperative complications [Nguyen et al, 2011]. Therefore, improvement of laparoscopic techniques for this disorder is very actual question. On the other hand, the mean rate of anatomical recurrence following laparoscopic repair of paraoesophageal hernias is 25 % as reported in a meta-analysis [Rathore et al, 2007]. It reaches 42 % in some centers according to recent literature reviews [Draaisma et al, 2005; Johnson et al, 2006]. Hence, creation of new method of hiatal repair diminishing recurrence rate is essential. To interventors' opinion, this new method must follow at least a principle of tension-free repair.
As the most concerning problem or repair of giant hiatal hernias is anatomical recurrence, a conception of prosthetic repair was applied for hiatal closure using different types of meshes. This dramatically decreased recurrence rate as demonstrated by several recent studies. Namely, Frantzides et al (2002) prospectively compared primary repair with on-lay PTFE repair and obtained statistically significant decrease of recurrence rate in favor of mesh arm: 0% versus 22%. Then, Granderath et al (2004) compared primary suturing and on-lay polypropylene mesh repair in prospective randomized trial; the rate of recurrence was significantly lower in the mesh arm: 8% versus 26%. Unfortunately, these studies were not primarily addressed to relation between hernia size and results. Most specialists use mesh when the diameter of the defect is just greater than 5 cm, based on own experience and widespread literature data, including studies of Champion et al (1998, 2003). Hiatal surface area (HSA), first described by Granderath et al (2007), is more sensitive measure than diameter of hiatal hernia defect, and further trials should focus on it.
However, SAGES trial reported by Frantzides et al. (2010) showed that polypropylene or PTFE meshes are characterized by the highest incidence of oesophageal complications although they demonstrated relatively lower recurrence rates compared to other meshes. According to most of the literature, mesh-related dysphagia rate is 10-15 % in the long-term follow-up [Granderath et al, 2005, Targarona et al, 2004]. Interestingly, that composite, i.e. partially absorbable meshes, occupied middle position in terms of recurrence and complications rates in this study [Frantzides et al, 2010]. Own experience of the interventors of more than 400 laparoscopic hiatal repairs using lightweight partially absorbable mesh (Ultrapro, Ethicon) showed minimal rate of recurrence (4,9 %) and dysphagia (2,1 %) for large (HSA 10-20 sq.cm) hernias [Grubnik et al, 2011]. The interventors applied this safe technique for giant (HSA > 20 sq.cm) hiatal hernias, but recurrence rate was 20 % [Grubnik et al, 2011]. This result corresponds to the literature, but may be improved. The interventors believe, it is possible to minimize recurrence rate of giant hiatal hernias, but it could be achieved by introduction of fundamentally new types of prostheses and methods of its fixation.
To remove the risk of mesh-related oesophageal complications of polypropylene or PTFE meshes, biological prostheses were introduced for hiatal repair. However, prospective randomized study by Oelschlager et al (2010) demonstrated insignificant difference in recurrence rates in prosthesis arm compared to primary repair arm (more than 50 %), although no cases of mesh-related complications were observed in prosthesis arm. Similar data regarding biological prostheses were retrieved in the study of Frantzides et al (2010). Data from the literature and international congresses suggest that current biological prostheses cannot be widely used in the setting of giant hiatal hernias due to high rate of recurrences and their high price. Thus, based on current literature data, there is insufficient grade 1 evidence for choice of optimal method of repair of giant hiatal hernias, and the search for the optimal prosthesis is still ongoing.
Therefore, a fundamentally new prosthesis for laparoscopic repair of giant hiatal defects was created. The prototype prosthesis "Rebound HRD-Hiatus hernia" was created by the interventors in collaboration with U.S. company, Minnesota Medical Development, Inc. This device is made from high quality lightweight PTFE mesh attached to a heart-shaped nitinol frame with a notch for oesophagus. Prosthesis may be easily inserted through the trocar using a special tube, and expanded to its initial form inside the abdomen. The principle and purpose of using of the device and method of its fixation was patented in Ukraine (patents No. 66397, 66399). The interventors applied new prosthesis in 29 patients, operated from 2010. All procedures were successfully completed. Two main principles are used in a new prosthesis. First, mesh is made of lightweight PTFE minimizing possibility of adhesions and related complications. As a result, there were no esophageal complications in the cohort. Second, peripheral nitinol frame of the prosthesis provides real tension-free repair without risk of prolapse between free, i.e. anterior, margin of the mesh and oesophagus, which other meshes do if fixed to the borders of the hiatus. As a result, there were no recurrences within mean surveillance of 15 months in this series. Naturally, final conclusions regarding superior efficacy and safety of the new device could be established by prospective randomized study.
Therefore, the hypothesis of this double-blind prospective randomized trial is: new method of nitinol-framed lightweight PTFE mesh (Rebound HRD-Hiatus hernia, Minnesota Medical Development, Inc) repair is more effective in terms of recurrence rate compared to sub-lay partially absorbable lightweight mesh (Ultrapro, Ethicon, Inc) repair, and is characterized by at least similar safety in terms of oesophageal complications.
The study will enroll at least 50 patients with giant (HSA > 20 sq.cm) types II and III hiatal hernias. The basic eligibility criteria will be: absence of oesophageal motility disorders, absence of oesophageal shortening requiring Collis procedure, absence of Barrett's oesophagus, peptic strictures and other factors that may independently influence the rate of recurrence and dysphagia/oesophageal strictures. Thus, the only difference between arms will be method of hiatal closure. To exclude fundoplication-related bias, standard floppy-Nissen procedure will be performed in every patient.
Every patient will be operated by single surgical team with an experience of more than 1500 laparoscopic anti-reflux procedures since 1998. The necessary ethic regulations will be saved including informed consent with the statement that patient is unaware of the method of repair (double-masked). Every patient will be evaluated preoperatively, 6 months, and 24 months postoperatively using symptom questionnaires, quality of life and satisfaction questionnaires, barium studies, endoscopic examinations, 24-hour pH testing, and analysis of possible reoperations. For issue of efficacy of prosthetic repair, recurrence rate of hernia and GERD, which are the primary outcome measure, will be studied. For issue of safety of prosthetic repair, rates of long-term dysphagia/oesophageal strictures/mesh erosions, which are main secondary outcome measure, will be evaluated.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Nitinol-framed PTFE mesh hiatal repair | Active comparator | Device: Nitinol-framed lightweight PTFE mesh for hiatal repairNitinol-framed lightweight PTFE mesh for hiatal repair |
| Lightweight mesh hiatal repair | Active comparator | Device: Partially absorbable lightweight mesh for hiatal repairPartially absorbable lightweight mesh for hiatal repair |
Who may qualify
- Ages
- 20 to 80 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Type II and III hiatal hernias, including complicated by GERD,
- Able to undergo elective laparoscopic hiatal hernia repair,
- Able to 24 months follow-up with office examinations,
- Hiatal surface area (HSA) exceeding 20 sq.cm (by Granderath et al, 2007) which correspond to the diameter of hernia defect exceeding 8 cm (the distinct size is determined intraoperatively, those with smaller diameter will be excluded from the study),
- Nissen fundoplication (intraoperative criterion)
Key exclusion criteria (13 listed)
- Unable to undergo laparoscopic hiatal hernia repair due to: severe comorbidities (ASA III and more), previous major surgery with severe adhesions, etc.
- Cases of conversion to open surgery
- Age < 20 years and > 80 years
- BMI < 16 and > 39 kg/sq.m
- Pregnancy or plans for pregnancy within next 2 years (in females)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Nitinol-framed lightweight PTFE mesh for hiatal repairAlso: Rebound HRD-Hiatus herniaThe heart-shaped nitinol-framed lightweight PTFE prosthesis "Rebound HRD-Hiatus hernia" (Minnesota Medical Development, Inc.) of small (4,0 x 4,5 cm) to large size (5,5 х 6,0 cm) is sutured to the crura posteriorly to oesophagus with 3 or 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures, thus performing complete tension-free hiatal repair. | Device | Nitinol-framed PTFE mesh hiatal repair |
| Partially absorbable lightweight mesh for hiatal repairAlso: UltraproA fashioned according to the dimensions of hernia defect partially absorbable lightweight mesh Ultrapro (Ethicon, Inc.) will be sutured to both crura posteriorly to oesophagus with 3 to 5 interrupted non-absorbable (Ethibond 3-0 by Ethicon, Inc.) sutures (as tension-free repair). Subsequent 2 to 3 interrupted non-absorbable sutures will approximate crura to completely cover a mesh to preclude its contact with the esophagus (original "sandwich" sub-lay technique). In both arms procedure will be done in a standard fashion: placement of 30 Fr esophageal bougie, reduction of hernia with excision of hernia sac and mobilization of distal esophagus, exposure of borders of hiatal opening, repair of hiatal hernia defect, a short (2,5 - 3,5 cm) 360° fundoplication wrap (floppy-Nissen procedure). | Device | Lightweight mesh hiatal repair |
Primary outcome
Anatomical and functional recurrence of hiatal hernia and GERD
Time frame: 24 months
Recurrence of hiatal hernia, i.e. anatomical recurrence, will be assessed by symptom questionnaire with visual analogue scales, mainly by barium study, and data from possible redo procedures. Recurrence of GERD, i.e. functional recurrence, will be evaluated by symptom questionnaire with visual analogue scales, endoscopic examination with assessment of degree of reflux-oesophagitis according to Los-Angeles classification, and 24 hour pH-testing with calculation of DeMeester score.
5 secondary outcomes
Repair-related dysphagia/oesophageal stricture/prosthetic erosion
Time frame: 24 months
Quality of life and satisfaction
Time frame: 24 months
Morbidity
Time frame: 1 month
Time to discharge
Time frame: 1 month
Number of participants completely recovered from extra-oesophageal complications of hiatal hernia following surgical procedure
Time frame: 24 months
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 30 Jun 2016.
- Background: PubMed 16151684Draaisma WA, Gooszen HG, Tournoij E, Broeders IA. Controversies in paraesophageal hernia repair: a review of literature. Surg Endosc. 2005 Oct;19(10):1300-8. doi: 10.1007/s00464-004-2275-3. Epub 2005 Aug 4.
- Background: PubMed 12049534Frantzides CT, Madan AK, Carlson MA, Stavropoulos GP. A prospective, randomized trial of laparoscopic polytetrafluoroethylene (PTFE) patch repair vs simple cruroplasty for large hiatal hernia. Arch Surg. 2002 Jun;137(6):649-52. doi: 10.1001/archsurg.137.6.649.
- Background: PubMed 15655204Granderath FA, Schweiger UM, Kamolz T, Asche KU, Pointner R. Laparoscopic Nissen fundoplication with prosthetic hiatal closure reduces postoperative intrathoracic wrap herniation: preliminary results of a prospective randomized functional and clinical study. Arch Surg. 2005 Jan;140(1):40-8. doi: 10.1001/archsurg.140.1.40.
- Background: PubMed 23272622Grubnik VV, Malinovskii AV. [Analysis of long-term results of laparoscopic repair of hiatal hernias and Nissen fundoplication]. Klin Khir. 2012 Oct;(10):34-6. No abstract available. Russian.
- Background: PubMed 21715189Oelschlager BK, Pellegrini CA, Hunter JG, Brunt ML, Soper NJ, Sheppard BC, Polissar NL, Neradilek MB, Mitsumori LM, Rohrmann CA, Swanstrom LL. Biologic prosthesis to prevent recurrence after laparoscopic paraesophageal hernia repair: long-term follow-up from a multicenter, prospective, randomized trial. J Am Coll Surg. 2011 Oct;213(4):461-8. doi: 10.1016/j.jamcollsurg.2011.05.017. Epub 2011 Jun 29.
- BackgroundChampion JK, McKernan JB. Hiatal size and risk of recurrence after laparoscopic fundoplication [abstract]. Surg Endosc. 1998; 12:565-570.
- Background: PubMed 12582773Champion JK, Rock D. Laparoscopic mesh cruroplasty for large paraesophageal hernias. Surg Endosc. 2003 Apr;17(4):551-3. doi: 10.1007/s00464-002-8817-7. Epub 2003 Feb 17.
- Background: PubMed 19997755Frantzides CT, Carlson MA, Loizides S, Papafili A, Luu M, Roberts J, Zeni T, Frantzides A. Hiatal hernia repair with mesh: a survey of SAGES members. Surg Endosc. 2010 May;24(5):1017-24. doi: 10.1007/s00464-009-0718-6. Epub 2009 Dec 8.
- Background: PubMed 17103275Granderath FA, Schweiger UM, Pointner R. Laparoscopic antireflux surgery: tailoring the hiatal closure to the size of hiatal surface area. Surg Endosc. 2007 Apr;21(4):542-8. doi: 10.1007/s00464-006-9041-7. Epub 2006 Nov 14.
- Background: PubMed 16437267Johnson JM, Carbonell AM, Carmody BJ, Jamal MK, Maher JW, Kellum JM, DeMaria EJ. Laparoscopic mesh hiatoplasty for paraesophageal hernias and fundoplications: a critical analysis of the available literature. Surg Endosc. 2006 Mar;20(3):362-6. doi: 10.1007/s00464-005-0357-5. Epub 2006 Jan 25.
- Background: PubMed 22127087Nguyen NT, Christie C, Masoomi H, Matin T, Laugenour K, Hohmann S. Utilization and outcomes of laparoscopic versus open paraesophageal hernia repair. Am Surg. 2011 Oct;77(10):1353-7.
- Background: PubMed 18237510Rathore MA, Andrabi SI, Bhatti MI, Najfi SM, McMurray A. Metaanalysis of recurrence after laparoscopic repair of paraesophageal hernia. JSLS. 2007 Oct-Dec;11(4):456-60.
Related trials for Hernia, Hiatal
Recruiting
GORE® ENFORM Biomaterial Product Study
Hernia, Ventral, Hernia, Hiatal
Active, not recruiting
Gastropexy in the Repair of Patients With Paraesophageal Hernias
Paraesophageal Hernia
Recruiting
Mesh Vs Pledgets for Repair of Paraesophageal Hernia
Paraesophageal Hernia, GERD
Recruiting
Phrenoesophageal Ligament Reconstruction With Mesh
Hiatus Hernia, Gastreoesophageal Reflux Disease
RecruitingObservational study
Preoperative Predictors of Symptom Improvement After Laparoscopic Fundoplication
Gastroesophageal Reflux Disease, Hiatal Hernia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Volodymyr V. Grubnik, Prof., MD principal investigator
Department of surgery No. 1 of Odessa national medical university
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 3 study testing Nitinol-framed lightweight PTFE mesh for hiatal repair and Partially absorbable lightweight mesh for hiatal repair in people with Hernia, Hiatal, run by Odessa National Medical University at 1 site in Ukraine.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 30 Jun 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Ukraine. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 3 studies compare the treatment with the current standard treatment or a placebo in a large group, to confirm how well it works and watch for side effects.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Anatomical and functional recurrence of hiatal hernia and GERD (time frame: 24 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01780285, which also lists 14 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Jun 2016.