Late Complication From Cardiac Pacemaker ImplantationNCT01682239
Effects of Right Ventricular Pacemaker Lead Position Assessed by MRI
A study testing RVAP and RVSP in people with Late Complication From Cardiac Pacemaker Implantation, run by Medical University of Vienna at 1 site in Austria.
Trial summary
Chronic right ventricular apical pacing has been associated with negative hemodynamic effects. Clinical outcome of right ventricular pacing can be influenced by multiple factors. An important factor seems to be optimal lead positioning. Read more about this study
- Who is it for?
- Ages 18 to 90 years
- Conditions the study is for
- Late Complication From Cardiac Pacemaker Implantation
- What is being tested?
- RVAP and RVSP
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 24 participants
- Where
- 1 siteAustria
- Study dates
- Sep 2012to Aug 2015
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 90 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- patients with dysrhythmia requiring dual-chamber pacemaker implantation
- planed MRI-pacemaker implantation (Accent MRI System,St. Jude Medical)
- age between 18-90 years
- no absolute pacemaker dependence
- no present heart failure or any significant coronary heart disease (exclusion by anamnesis and echocardiography - LVH <15mm, LV EF>50%)
- no previous myocardial infarction or significant coronary artery disease
- life expectancy > 1 year
- patients willing to participate in follow-up
Who cannot join
- Contraindications for MRI (Brain aneurysm clips, artificial heart valves, artificial joints, vascular stents)
- Any contraindication for surgery
- Absolute pacemaker dependence
- Claustrophobia
- GFR<30ml/min/1,73m2
- Allergy to contrast agent
Trial locations and contacts
1 site in 1 country.
Austria1 site
Department of Cardiac Surgery, MUV
Vienna, State of Vienna, 1090
About this study
Official title: Effects of Different Right Ventricular Lead Positioning on Cardiac Contraction Measured by Cardiac MRI: a Pilot Trial
Chronic right ventricular apical pacing has been associated with negative hemodynamic effects. Clinical outcome of right ventricular pacing can be influenced by multiple factors. An important factor seems to be optimal lead positioning. Data regarding left ventricular function impaired by lead positioning is insufficient. The aim of the present study therefore is to compare right ventricular apical pacing (RVAP) with right ventricular septal pacing (RVSP). Outcome measurements are echocardiographic features, magnetic resonance imaging and clinical outcome.
- Being tested
- RVAP, RVSP
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
RVAPOther
In this arm pacemaker leads will be placed in the RV apex.
RVSPOther
In this arm pacemaker leads will be placed in the RV septum.
| Study group | Role | What they receive |
|---|---|---|
| RVAP lead | Experimental | Pacemaker lead implantation:
Pacemaker leads will be placed in specific predefined RA and RV sites according to randomization. In this arm pacemaker leads will be placed in the RV apex. The successful lead positioning at its target location will be verified by surface ECG and by fluoroscopy. Receives: Other: RVAP |
| RVSP arm | Experimental | Pacemaker lead implantation:
Pacemaker leads will be placed in specific predefined RA and RV sites according to randomization. In this arm pacemaker leads will be placed in the RV septum. The successful lead positioning at its target location will be verified by surface ECG and by fluoroscopy. Receives: Other: RVSP |
What is being measured
The primary outcome is the main question the study is designed to answer.
Ejection Fraction
As primary endpoint the difference of ventricular function in both groups will be taken. Therefore the Ejection Fraction is measured in cardiac MRI and Echocardiography. There may be a different development of contraction, whether the lead is placed in the ventricular apex or the ventricular septum.
Measured: 6 month
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted10 Sep 2012 (estimated)
- Study startSep 2012
- Primary completionAug 2014 (estimated)
- Study completionAug 2015 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (3)Papers the sponsor has linked to this study.
- Other trials for Late Complication From Cardiac Pacemaker ImplantationStudies of the same condition, open and under way.
- More trials run by Medical University of ViennaThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Basic science
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 24 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Medical University of Vienna
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Alfred A Kocher, MD, Medical University of Vienna
- Investigators
- Alfred Kocher, MD, Principal investigator, Department of Cardiac Surgery
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01682239
- Sponsor's protocol ID
- EC 023/2012
- Status last verified
- Sep 2012
- First submitted
- 6 Sep 2012
- Last updated
- 10 Sep 2012
- Results posted
- No
- Data monitoring committee
- Yes
Publications
Beinart R, Nazarian S. MRI-Conditional Cardiac Implantable Electronic Devices: What's New and What Can We Expect in the Future? Curr Treat Options Cardiovasc Med. 2012 Oct;14(5):558-64. doi: 10.1007/s11936-012-0197-2.
PubMed 22851216Cano O, Osca J, Sancho-Tello MJ, Sanchez JM, Ortiz V, Castro JE, Salvador A, Olague J. Comparison of effectiveness of right ventricular septal pacing versus right ventricular apical pacing. Am J Cardiol. 2010 May 15;105(10):1426-32. doi: 10.1016/j.amjcard.2010.01.004. Epub 2010 Mar 30.
PubMed 20451689Inoue K, Okayama H, Nishimura K, Saito M, Yoshii T, Hiasa G, Sumimoto T, Inaba S, Suzuki J, Ogimoto A, Funada J, Higaki J. Right ventricular septal pacing preserves global left ventricular longitudinal function in comparison with apical pacing: analysis of speckle tracking echocardiography. Circ J. 2011;75(7):1609-15. doi: 10.1253/circj.cj-10-1138. Epub 2011 May 20.
PubMed 21597204
Study at a glance
From the registry record, last updated by the sponsor on 10 Sep 2012. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Effects of Different Right Ventricular Lead Positioning on Cardiac Contraction Measured by Cardiac MRI: a Pilot Trial
- ClinicalTrials.gov ID
- NCT01682239
- Acronym / sponsor ID
- EC 023/2012
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 24 participants (estimated)
- Lead sponsor
- Medical University of ViennaUniversity, hospital or other
- Study start
- Sep 2012
- Primary completion
- Aug 2014 (estimated)
- Study completion
- Aug 2015 (estimated)
- First posted
- 10 Sep 2012 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Chronic right ventricular apical pacing has been associated with negative hemodynamic effects. Clinical outcome of right ventricular pacing can be influenced by multiple factors. An important factor seems to be optimal lead positioning. Data regarding left ventricular function impaired by lead positioning is insufficient. The aim of the present study therefore is to compare right ventricular apical pacing (RVAP) with right ventricular septal pacing (RVSP). Outcome measurements are echocardiographic features, magnetic resonance imaging and clinical outcome.
Study design
- Primary purpose
- Basic science
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| RVAP lead | Experimental | Other: RVAPPacemaker lead implantation: Pacemaker leads will be placed in specific predefined RA and RV sites according to randomization. In this arm pacemaker leads will be placed in the RV apex. The successful lead positioning at its target location will be verified by surface ECG and by fluoroscopy. |
| RVSP arm | Experimental | Other: RVSPPacemaker lead implantation: Pacemaker leads will be placed in specific predefined RA and RV sites according to randomization. In this arm pacemaker leads will be placed in the RV septum. The successful lead positioning at its target location will be verified by surface ECG and by fluoroscopy. |
Who may qualify
- Ages
- 18 to 90 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (8 listed)
- patients with dysrhythmia requiring dual-chamber pacemaker implantation
- planed MRI-pacemaker implantation (Accent MRI System,St. Jude Medical)
- age between 18-90 years
- no absolute pacemaker dependence
- no present heart failure or any significant coronary heart disease (exclusion by anamnesis and echocardiography - LVH <15mm, LV EF>50%)
Key exclusion criteria (6 listed)
- Contraindications for MRI (Brain aneurysm clips, artificial heart valves, artificial joints, vascular stents)
- Any contraindication for surgery
- Absolute pacemaker dependence
- Claustrophobia
- GFR<30ml/min/1,73m2
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| RVAPIn this arm pacemaker leads will be placed in the RV apex. | Other | RVAP lead |
| RVSPIn this arm pacemaker leads will be placed in the RV septum. | Other | RVSP arm |
Primary outcome
Ejection Fraction
Time frame: 6 month
As primary endpoint the difference of ventricular function in both groups will be taken. Therefore the Ejection Fraction is measured in cardiac MRI and Echocardiography. There may be a different development of contraction, whether the lead is placed in the ventricular apex or the ventricular septum.
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 10 Sep 2012.
- Background: PubMed 22851216Beinart R, Nazarian S. MRI-Conditional Cardiac Implantable Electronic Devices: What's New and What Can We Expect in the Future? Curr Treat Options Cardiovasc Med. 2012 Oct;14(5):558-64. doi: 10.1007/s11936-012-0197-2.
- Background: PubMed 20451689Cano O, Osca J, Sancho-Tello MJ, Sanchez JM, Ortiz V, Castro JE, Salvador A, Olague J. Comparison of effectiveness of right ventricular septal pacing versus right ventricular apical pacing. Am J Cardiol. 2010 May 15;105(10):1426-32. doi: 10.1016/j.amjcard.2010.01.004. Epub 2010 Mar 30.
- Background: PubMed 21597204Inoue K, Okayama H, Nishimura K, Saito M, Yoshii T, Hiasa G, Sumimoto T, Inaba S, Suzuki J, Ogimoto A, Funada J, Higaki J. Right ventricular septal pacing preserves global left ventricular longitudinal function in comparison with apical pacing: analysis of speckle tracking echocardiography. Circ J. 2011;75(7):1609-15. doi: 10.1253/circj.cj-10-1138. Epub 2011 May 20.
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Alfred Kocher, MD principal investigator
Department of Cardiac Surgery
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing RVAP and RVSP in people with Late Complication From Cardiac Pacemaker Implantation, run by Medical University of Vienna at 1 site in Austria.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 8 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 10 Sep 2012. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Austria. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Ejection Fraction (time frame: 6 month). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01682239, which also lists 3 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Sep 2012.