BradycardiaENHANCENCT01559311
ENHANCE-Efficacy of the Presence of Right Ventricular Apical Pacing Induced Ventricular Dyssynchrony as a Guiding Parameter for Biventricular Pacing in Patients With Bradycardia and Normal Ejection Fraction
A study testing CRT-P OFF, CRT-P ON and DDDR in people with Bradycardia, run by Abbott Medical Devices at 7 sites in 5 countries.
Trial summary
The purpose of this clinical project is to evaluate the efficacy of the presence of Right Ventricular Apical (RVA) pacing induced ventricular dyssynchrony as a guiding parameter for bi-ventricular pacing in patients with bradycardia and normal left ventricular ejection fraction (LVEF). Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Bradycardia
- What is being tested?
- CRT-P OFF, CRT-P ON and DDDR
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 98 participants
- Where
- 7 sitesin 5 countries
- Study dates
- Feb 2012to Apr 2016
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patient meets current indications for implantation of a DDDR pacemaker
- Patient is geographically stable and willing to comply with the required follow-up schedule
- Patient has LVEF >45%
- Patient has atrioventricular block (IIo or above)
- Patient has adequate echocardiographic images to measure LV volumes and LVEF
Who cannot join
- Patient has permanent atrial fibrillation (AF)
- Patient has unstable angina or an acute coronary syndrome
- Patient has undergone percutaneous coronary intervention or coronary artery bypass surgery within the previous 3 months
- Patient's life expectancy is less than 1 year
- Patient is less than 18 years old
- Patient is pregnant
- Patient has received a heart transplant
Trial locations and contacts
7 sites in 5 countries.
7 sites in 5 countries
India3 sites
Madras Medical Mission
Chennai
CARE Banjara
Hyderabad
All India Institute of Medical Sciences
New Delhi
About this study
Official title: Efficacy of the Presence of Right Ventricular Apical Pacing Induced Ventricular Dyssynchrony as a Guiding Parameter for Biventricular Pacing in Patients With Bradycardia and Normal Ejection Fraction
The purpose of this clinical project is to evaluate the efficacy of the presence of Right Ventricular Apical (RVA) pacing induced ventricular dyssynchrony as a guiding parameter for bi-ventricular pacing in patients with bradycardia and normal left ventricular ejection fraction (LVEF). The results of this project may provide with the evidence based medicine for guidelines expansion of using Cardiac resynchronization therapy (CRT) in patients with Heart Block and normal LVEF (LVEF >45%).
Read the detailed description
All eligible patients willing to provide written informed consent were invited to participate in the study, and then randomized 1:2 to either the Control Group or Echo-guided Group. Patients randomized into the Control Group were implanted with a dual chamber pacemaker (DDDR) device (St. Jude Medical) standard therapy. Patients randomized into the Echo-guided Group were implanted with a cardiac resynchronization therapy pacemaker (CRT-P) device (St. Jude Medical), which was programmed to DDDR pacing mode (CRT-P OFF) at implant. For each Echo-guided Group patient, presence of RVA pacing induced ventricular dyssynchrony was assessed within 24-hour of implant using the standardized criteria of Doppler echocardiography. The Echocardiography Core Laboratory (Echo Core Lab) then analyzed each image and the treatment allocation of the Echo-guided Group was done within 72-hour post implant based on the Echo Core Lab outcomes:
- Patients with the presence of RVA pacing induced ventricular dyssynchrony were allocated to the CRT-P standard therapy with CRT-P turned ON
- Patients with the absence of RVA pacing induced ventricular dyssynchrony were allocated to the DDDR standard therapy with CRT-P remained OFF
Patients meeting all the inclusion criteria and not meeting any of the exclusion criteria were eligible for the study. Data was collected at the following study visits:Enrollment, Implant \& Randomization, Pre-discharge (PDH) (≤ 72 hours post implant), Month 1 follow-up visit: 30 ± 14 days post implant, Month 3 follow-up visit: 90 ± 14 days post implant, Month 6 follow-up visit: 180 ± 14 days post implant and Month 12 follow-up visit: 365 ± 14 days post implant
- Conditions
- Bradycardia
- Being tested
- CRT-P OFF, CRT-P ON, DDDR
- Keywords
- Bradycardia
- Medical subject headings
- Bradycardia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
CRT-P OFFDevice
CRT Pacemaker
CRT-P ONDevice
CRT Pacemaker
DDDRDevice
Dual-chamber, rate-modulated pacemaker
| Study group | Role | What they receive |
|---|---|---|
| CRT-P OFF | Active comparator | Patients randomized into the Echo-guided Group were implanted with a CRT-P device (St. Jude Medical), which was programmed to DDDR pacing mode (CRT-P OFF) at implant. For each Echo-guided Group patient, presence of RVA pacing induced ventricular dyssynchrony was assessed within 24-hour of implant using the standardized criteria of Doppler echocardiography. The Echocardiography Core Laboratory (Echo Core Lab) then analyzed each image and the treatment allocation of the Echo-guided Group was done within 72-hour post implant based on the Echo Core Lab outcomes:
• Patients with the absence of RVA pacing induced ventricular dyssynchrony were allocated to the DDDR standard therapy with CRT-P remained OFF Receives: Device: CRT-P OFF |
| CRT-P ON | Experimental | Patients randomized into the Echo-guided Group were implanted with a CRT-P device (St. Jude Medical), which was programmed to DDDR pacing mode (CRT-P OFF) at implant. For each Echo-guided Group patient, presence of RVA pacing induced ventricular dyssynchrony was assessed within 24-hour of implant using the standardized criteria of Doppler echocardiography. The Echocardiography Core Laboratory (Echo Core Lab) then analyzed each image and the treatment allocation of the Echo-guided Group was done within 72-hour post implant based on the Echo Core Lab outcomes:
• Patients with the presence of RVA pacing induced ventricular dyssynchrony were allocated to the CRT-P standard therapy with CRT-P turned ON Receives: Device: CRT-P ON |
| DDDR | Active comparator | Patients randomized into the Control Group were implanted with a DDDR device (St. Jude Medical) standard therapy. Receives: Device: DDDR |
What is being measured
The primary outcome is the main question the study is designed to answer.
LVEF
Left Ventricular Ejection Fraction (LVEF) for assessment of Left ventricular (LV) systolic function
Measured: 12 months
LVESV
Left ventricular end-systolic volume (LVESV) for assessment of LV remodeling
Measured: 12 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Mar 2012 (estimated)
- Study startFeb 2012
- Primary completionNov 2015
- Study completionApr 2016
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for BradycardiaStudies of the same condition, open and under way.
- More trials run by Abbott Medical DevicesThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 98 participants (actual)
Sponsor and investigators
- Lead sponsor
- Abbott Medical Devices
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Cheuk Man Yu, MD, Principal investigator, Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, New Territories, Hong Kong
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01559311
- Sponsor's protocol ID
- CR-10-003-AP-HF
- Acronym
- ENHANCE
- Status last verified
- Jan 2019
- First submitted
- 19 Mar 2012
- Last updated
- 4 Feb 2019
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Study at a glance
From the registry record, last updated by the sponsor on 4 Feb 2019. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Efficacy of the Presence of Right Ventricular Apical Pacing Induced Ventricular Dyssynchrony as a Guiding Parameter for Biventricular Pacing in Patients With Bradycardia and Normal Ejection Fraction
- ClinicalTrials.gov ID
- NCT01559311
- Acronym / sponsor ID
- ENHANCE / CR-10-003-AP-HF
- Conditions
- Bradycardia
- Keywords
- Bradycardia
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 98 participants (actual)
- Lead sponsor
- Abbott Medical DevicesIndustry (pharma, biotech, devices)
- Study start
- Feb 2012
- Primary completion
- Nov 2015 (actual)
- Study completion
- Apr 2016 (actual)
- First posted
- 21 Mar 2012 (estimated)
- Results
- Posted 31 Oct 2016
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this clinical project is to evaluate the efficacy of the presence of Right Ventricular Apical (RVA) pacing induced ventricular dyssynchrony as a guiding parameter for bi-ventricular pacing in patients with bradycardia and normal left ventricular ejection fraction (LVEF). The results of this project may provide with the evidence based medicine for guidelines expansion of using Cardiac resynchronization therapy (CRT) in patients with Heart Block and normal LVEF (LVEF >45%).
Detailed description
All eligible patients willing to provide written informed consent were invited to participate in the study, and then randomized 1:2 to either the Control Group or Echo-guided Group. Patients randomized into the Control Group were implanted with a dual chamber pacemaker (DDDR) device (St. Jude Medical) standard therapy. Patients randomized into the Echo-guided Group were implanted with a cardiac resynchronization therapy pacemaker (CRT-P) device (St. Jude Medical), which was programmed to DDDR pacing mode (CRT-P OFF) at implant. For each Echo-guided Group patient, presence of RVA pacing induced ventricular dyssynchrony was assessed within 24-hour of implant using the standardized criteria of Doppler echocardiography. The Echocardiography Core Laboratory (Echo Core Lab) then analyzed each image and the treatment allocation of the Echo-guided Group was done within 72-hour post implant based on the Echo Core Lab outcomes:
- Patients with the presence of RVA pacing induced ventricular dyssynchrony were allocated to the CRT-P standard therapy with CRT-P turned ON
- Patients with the absence of RVA pacing induced ventricular dyssynchrony were allocated to the DDDR standard therapy with CRT-P remained OFF
Patients meeting all the inclusion criteria and not meeting any of the exclusion criteria were eligible for the study. Data was collected at the following study visits:Enrollment, Implant \& Randomization, Pre-discharge (PDH) (≤ 72 hours post implant), Month 1 follow-up visit: 30 ± 14 days post implant, Month 3 follow-up visit: 90 ± 14 days post implant, Month 6 follow-up visit: 180 ± 14 days post implant and Month 12 follow-up visit: 365 ± 14 days post implant
Study design
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| CRT-P OFF | Active comparator | Device: CRT-P OFFPatients randomized into the Echo-guided Group were implanted with a CRT-P device (St. Jude Medical), which was programmed to DDDR pacing mode (CRT-P OFF) at implant. For each Echo-guided Group patient, presence of RVA pacing induced ventricular dyssynchrony was assessed within 24-hour of implant using the standardized criteria of Doppler echocardiography. The Echocardiography Core Laboratory (Echo Core Lab) then analyzed each image and the treatment allocation of the Echo-guided Group was done within 72-hour post implant based on the Echo Core Lab outcomes: • Patients with the absence of RVA pacing induced ventricular dyssynchrony were allocated to the DDDR standard therapy with CRT-P remained OFF |
| CRT-P ON | Experimental | Device: CRT-P ONPatients randomized into the Echo-guided Group were implanted with a CRT-P device (St. Jude Medical), which was programmed to DDDR pacing mode (CRT-P OFF) at implant. For each Echo-guided Group patient, presence of RVA pacing induced ventricular dyssynchrony was assessed within 24-hour of implant using the standardized criteria of Doppler echocardiography. The Echocardiography Core Laboratory (Echo Core Lab) then analyzed each image and the treatment allocation of the Echo-guided Group was done within 72-hour post implant based on the Echo Core Lab outcomes: • Patients with the presence of RVA pacing induced ventricular dyssynchrony were allocated to the CRT-P standard therapy with CRT-P turned ON |
| DDDR | Active comparator | Device: DDDRPatients randomized into the Control Group were implanted with a DDDR device (St. Jude Medical) standard therapy. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Patient meets current indications for implantation of a DDDR pacemaker
- Patient is geographically stable and willing to comply with the required follow-up schedule
- Patient has LVEF >45%
- Patient has atrioventricular block (IIo or above)
- Patient has adequate echocardiographic images to measure LV volumes and LVEF
Key exclusion criteria (7 listed)
- Patient has permanent atrial fibrillation (AF)
- Patient has unstable angina or an acute coronary syndrome
- Patient has undergone percutaneous coronary intervention or coronary artery bypass surgery within the previous 3 months
- Patient's life expectancy is less than 1 year
- Patient is less than 18 years old
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| CRT-P OFFCRT Pacemaker | Device | CRT-P OFF |
| CRT-P ONCRT Pacemaker | Device | CRT-P ON |
| DDDRDual-chamber, rate-modulated pacemaker | Device | DDDR |
Primary outcome
LVEF
Time frame: 12 months
Left Ventricular Ejection Fraction (LVEF) for assessment of Left ventricular (LV) systolic function
LVESV
Time frame: 12 months
Left ventricular end-systolic volume (LVESV) for assessment of LV remodeling
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 4 Feb 2019.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Bradycardia
Not yet recruiting
nCPAP-NAVA-Backup Versus Standard nCPAP for Severe Apnea in Preterm Infants ≤28 Weeks
Apnea of Prematurity
RecruitingObservational study
Leadless Pacemaker Registry: Outcomes and Follow-up From the University Hospital of St. Pölten
Pacemaker, Leadless Pacemaker
RecruitingObservational study
Product Performance Report: Evaluate Long-term Reliability & Performance of Medtronic Marketed Cardiac Therapy Products
Arrhythmia, Bradycardia
Active, not recruitingObservational study
Safety, Performance, and Clinical Benefit of Pacing the Left Bundle Branch Area - Post-Market Clinical Follow-up
Bradycardia, Atrioventricular Block
RecruitingObservational study
BIO|STREAM.CSP Study
Cardiac Pacing, Cardiac Pacemaker
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Cheuk Man Yu, MD principal investigator
Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, New Territories, Hong Kong
7 sites in 5 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing CRT-P OFF, CRT-P ON and DDDR in people with Bradycardia, run by Abbott Medical Devices at 7 sites in 5 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 4 Feb 2019. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 7 sites in India, Australia, China, Italy, Thailand. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 31 Oct 2016). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
LVEF (time frame: 12 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.