Accuracy of the O2 MedTech PMS-3000 Monitor

A Phase 2 study testing O2 MedTech cerebral oximeter (Oxygen desaturation) in people with Healthy, run by O2 MedTech, Inc. at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

A cerebral oximeter is a device that uses light to measure the amount of oxygen within the brain. It is similar to the device that measures the level of oxygen in the tip of the finger, known as a pulse oximeter. Read more about this study

Who is it for?
Ages 18 to 50 yearsHealthy volunteers can take part
Conditions the study is for
Healthy
What is being tested?
O2 MedTech cerebral oximeter (Oxygen desaturation)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
42 participants
Where
1 siteUnited States
Study dates
Aug 2011to Feb 2012
Phase
Phase 2
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 50 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Body Mass Index (BMI) of 18 to 30, inclusive
  • No anticoagulant or platelet inhibitor use
  • Oxygen saturation (SpO2) ≥ 95% on room air
  • Able to tolerate breathing mask apparatus

Who cannot join

  • Female with positive pregnancy test
  • Beard or history of or anatomy suggestive of difficult airway
  • Lab values outside normal range for the clinical site
  • History of cigarette smoking or currently a cigarette smoker
  • Current drug or alcohol abuse
  • History of sleep apnea, high blood pressure (HBP), cardiac or pulmonary disease, gastroesophageal reflux, hemoglobinopathy, or coagulation abnormality
  • Known allergy to lidocaine or heparin
  • Abnormal electrocardiogram (ECG)

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Duke University Medical Center

    Durham, North Carolina, 27705

Other trials in United States

About this study

Official title: Accuracy of the O2 MedTech PMS-3000 Monitor for the Non-invasive Measurement of Cerebral and Tissue Oxygenation Using Phase-modulated Infrared Spectroscopy

A cerebral oximeter is a device that uses light to measure the amount of oxygen within the brain. It is similar to the device that measures the level of oxygen in the tip of the finger, known as a pulse oximeter. The cerebral oximeter consists of a sensor placed on the forehead that both emits and detects the amount of light absorbed. This study will determine how accurate the device is by comparing the displayed value on the monitor with blood samples taken simultaneously from the arterial blood in the wrist and venous blood in the neck. In order to test the device over a suitable range, the level of oxygen within the blood will be reduced in a controlled manner by reduction of the inspired oxygen concentration. This is the equivalent of ascending to an altitude of 16,000 feet. The study will be conducted in healthy volunteers.

Read the detailed description

This is a calibration and validation study of a near-infrared spectroscopy (NIRS) device designed to measure the cerebral tissue oxygen saturation non-invasively. This is achieved by comparing NIRS-derived cerebral tissue oxygen saturation with a calculated value derived from simultaneous arterial and jugular venous blood samples.

At present the FDA have adopted the standards published in 2005 by the International Organization for Standardization (ISO), entitled ISO 9919. This is a set of technical specifications and guidelines for pulse oximeters, which share certain technical similarities to cerebral oximeters. In particular, Annex EE details the conduct of a controlled desaturation study for the calibration of pulse oximeter equipment. Specifically, the fraction of inspired oxygen delivered to test subjects is varied to achieve a series of targeted steady state saturation periods over a range of arterial oxygen saturation of 70 - 100%.

While cerebral oximeters differ from pulse oximeters in terms of the what is being measured (brain tissue versus arterial blood) the FDA have maintained the requirement to examine data from human volunteer studies in which the arterial oxygen saturation ranges from 70 - 100%. Several FDA-approved cerebral oximeters were validated in a similar manner.

The device controlling the inspired gas concentration is the RespirAct, which permits precise reduction in the arterial oxygen saturation while also maintaining the arterial carbon dioxide level at a precise level.

The study consists of 2 sequences:

  • First sequence: reduction in arterial oxygen saturation in approximately 5% increments from 100 to 70%, while maintaining the arterial carbon dioxide level at 40 mmHg, followed by return to room air and then a period of supplemental oxygen.
  • Second sequence: reduction in arterial oxygen saturation in approximately 5% increments from 100 to 70%, while maintaining the arterial carbon dioxide level at a different level, followed by return to room air and then a period of supplemental oxygen.
Conditions
Healthy
Being tested
O2 MedTech cerebral oximeter (Oxygen desaturation)
Keywords
Spectroscopy, near infrared, cerebral oxygenation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • O2 MedTech cerebral oximeter (Oxygen desaturation)Device

    Also called PMS-3000 cerebral oximeter

    Reduction in blood oxygen saturation by sequential reduction in inspired gas composition. Steps are of 6 minutes duration with reduction in pulse oximeter oxygen saturation from 100 to 70%.

Study groups in NCT01418079
Study groupRoleWhat they receive
PMS-3000ExperimentalHuman volunteers undergo oxygen desaturation in order to determine the accuracy of the device over a clinical range of oxygen saturations 70 - 100%.
Receives: Device: O2 MedTech cerebral oximeter (Oxygen desaturation)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of device to measure cerebral tissue oxygen saturation

    Oximeter measurements are compared to co-oximeter measurements following each subject study. The total sample of subjects is needed to complete the analysis.

    Measured: approximately 4 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Aug 2011 (estimated)
  2. Study startAug 2011
  3. Primary completionFeb 2012
  4. Study completionFeb 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 2
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Single group
Masking
None (open label)
Enrolment
42 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01418079
Sponsor's protocol ID
MT2010001
Status last verified
May 2012
First submitted
12 Aug 2011
Last updated
23 May 2012
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A Phase 2 study testing O2 MedTech cerebral oximeter (Oxygen desaturation) in people with Healthy, run by O2 MedTech, Inc. at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 23 May 2012. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of device to measure cerebral tissue oxygen saturation (time frame: approximately 4 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 May 2012.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in