AzTrials
AzTrials

Coronary Artery DiseaseSPECT-LightNCT01412827

Accuracy of Half of the Usual Radiotracer Dose in SPECT

A study testing 1/2 dose of 99mTc OR 201Tl tracers in people with Coronary Artery Disease, run by Ottawa Heart Institute Research Corporation at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

There has been a shortage of nuclear isotopes, not only in Canada but around the world. New, more sensitive SPECT cameras can obtain better images in shorter scan times. These cameras have also shown the ability to use a smaller dose of radioisotope to obtain the images. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Disease
What is being tested?
1/2 dose of 99mTc OR 201Tl tracers
Could I receive a placebo?
No, everyone receives an active treatment
How many people
18 participants
Where
1 siteCanada
Study dates
Apr 2010to Sep 2014
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Consecutive patients presenting for clinically indicated SPECT perfusion scan
  • Patients presenting to sites with a functional CZT camera. Available sites are Ottawa (OHI), Mississauga, and Calgary.
  • Age >18 years old

Who cannot join

  • Patients with a life expectancy less than 1 year, from non cardiac cause
  • Age < 18 years old or lack of consent
  • Allergy or contraindication to dipyridamole
  • Refractory angina or infarction or need for urgent angiography
  • Known pregnancy
  • Uncontrolled atrial fibrillation

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • University of Ottawa Heart Institute

    Ottawa, Ontario

Other trials in Canada

About this study

Official title: Diagnostic and Prognostic Accuracy of Stress SPECT Myocardial Perfusion Imaging With Half the Usual Radiotracer Dose

There has been a shortage of nuclear isotopes, not only in Canada but around the world. New, more sensitive SPECT cameras can obtain better images in shorter scan times. These cameras have also shown the ability to use a smaller dose of radioisotope to obtain the images. New software has been tested on the standard camera, the GE Infinia-Hawkeye SPECT/CT. The Diagnostic Imaging Department of The University of Ottawa Heart Institute has also acquired a new camera, the Discovery NM530c CZT and has been doing heart scans in shorter times. The investigators will now be looking at the quality of images using less isotope during SPECT myocardial perfusion imaging for diagnostic and prognostic purposes.

Read the detailed description

SPECT MPI is well accepted as a reliable and cost-effective tool for diagnosis, risk stratification and management of patients with suspected or known coronary artery disease (CAD) (1;2). MPI represents approximately 40% of nuclear medicine patient studies and most of these use 99mTc-sestamibi or 99mTc-tetrofosmin(3). Rest/stress MPI using 99mTc-sestamibi and 99mTc-tetrofosmin uses more tracer doses than many other nuclear medicine tests and thus account for >50% of injected radiotracer activity(3). Thus, interruptions in the supply of 99Mo, the parent isotope of 99mTc, significantly affect stress MPI imaging and associated patient care.

Alternatives to 99mTc-sestamibi and 99mTc-tetrofosmin for perfusion imaging include 201Tl for SPECT imaging and 82Rb or 13NH3 for positron emission tomography (PET) imaging (4;5). MPI using 201Tl has similar diagnostic accuracy but image interpretation is more difficult due to greater scatter and attenuation. Moreover, the patient effective radiation dose for MPI using a standard injected dose of 3.5mCi of 201Tl is ~20 mSv. This radiation dose is twice that of 99mTc tracers which typically deliver an effective dose of ~10 mSv. PET imaging with 82Rb or 13NH3 is another alternative, but is much more expensive and not routinely available in Canada due to a very limited install base of PET scanners and associated cyclotrons. The number of SPECT cameras operational in Canada is more than 40 times the number of PET scanners.

Being tested
1/2 dose of 99mTc OR 201Tl tracers
Keywords
Single-photon emission computed tomography, myocardial perfusion imaging, rest/stress, treadmill, persantine, half-dose, radiotracer, tetrofosmin, Thallium, cadmium zinc telluride, diagnostic, prognostic
Medical subject headings
Coronary Artery Disease, Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • 1/2 dose of 99mTc OR 201Tl tracersRadiation

    Rest: Imaging will occur 30 to 60 minutes after injection of tracer.

    Stress: All patients will undergo a symptom-limited Bruce protocol treadmill exercise test. At peak stress, the radiotracer will be injected intravenously, and exercise will continue for an additional 60 s. The patients who are unable to achieve the targeted heart rate or exercise will be stressed pharmacologically. Dipyridamole (0.142 mg/kg/min) will be infused intravenously for 5 minutes, and 99mTc radiotracer will be injected at 2 min after infusion completion (7 min into the study). Aminophylline (100-200 mg) will be given intravenously 2 min after injection of the radiotracer.

Study groups in NCT01412827
Study groupRoleWhat they receive
Comparison of radioisotope dosingOtherNot described
Receives: Radiation: 1/2 dose of 99mTc OR 201Tl tracers

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Rate of non-fatal infarction or death in the normal group of SPECT-Light acquisitions versus standard SPECT acquisitions

    The difference in the rate of non-fatal infarction or death that occurs in the normal group of the combined SPECT-Light acquisition protocols (LDa and LDb) versus the outcome that occurs in the acquisitions obtained by the standard SPECT (FD) protocol.

    Measured: 2 years

Secondary outcomes (1)
  1. Comparison of classification of the degree of abnormality based on the two image acquisition protocols

    A comparison of classification of the degree of abnormality based on the two image acquisition protocols. Multi-level correlation between the two image sets (LDa vs 2 and LDb vs 2) will be obtained against the standard SPECT (FD) images.

    The combined rates of non-fatal MI or death in each of the LD images as well as the standard dose images (FD) which are considered abnormal (SSS ≥ 4) will also be calculated.

    Measured: 2 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Aug 2011 (estimated)
  2. Study startApr 2010
  3. Primary completionMar 2013
  4. Study completionSep 2014

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
18 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01412827
Sponsor's protocol ID
HI Protocol #2010127-01H
Acronym
SPECT-Light
Status last verified
Feb 2016
First submitted
7 Aug 2011
Last updated
24 Feb 2016
Results posted
No
Data monitoring committee
No

Publications

  • Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Stress myocardial perfusion single-photon emission computed tomography is clinically effective and cost effective in risk stratification of patients with a high likelihood of coronary artery disease (CAD) but no known CAD. J Am Coll Cardiol. 2004 Jan 21;43(2):200-8. doi: 10.1016/j.jacc.2003.07.043.

    PubMed 14736438
  • Marcassa C, Bax JJ, Bengel F, Hesse B, Petersen CL, Reyes E, Underwood R; European Council of Nuclear Cardiology (ECNC); European Society of Cardiology Working Group 5 (Nuclear Cardiology and Cardiac CT); European Association of Nuclear Medicine Cardiovascular Committee. Clinical value, cost-effectiveness, and safety of myocardial perfusion scintigraphy: a position statement. Eur Heart J. 2008 Feb;29(4):557-63. doi: 10.1093/eurheartj/ehm607. Epub 2008 Jan 17.

    PubMed 18202253
  • Beanlands RS, Chow BJ, Dick A, Friedrich MG, Gulenchyn KY, Kiess M, Leong-Poi H, Miller RM, Nichol G, Freeman M, Bogaty P, Honos G, Hudon G, Wisenberg G, Van Berkom J, Williams K, Yoshinaga K, Graham J; Canadian Cardiovascular Society; Canadian Association of Radiologists; Canadian Association of Nuclear Medicine; Canadian Nuclear Cardiology Society; Canadian Society of Cardiac Magnetic Resonance. CCS/CAR/CANM/CNCS/CanSCMR joint position statement on advanced noninvasive cardiac imaging using positron emission tomography, magnetic resonance imaging and multidetector computed tomographic angiography in the diagnosis and evaluation of ischemic heart disease--executive summary. Can J Cardiol. 2007 Feb;23(2):107-19. doi: 10.1016/s0828-282x(07)70730-4.

    PubMed 17311116

Questions about this trial

What is this clinical trial studying?

A study testing 1/2 dose of 99mTc OR 201Tl tracers in people with Coronary Artery Disease, run by Ottawa Heart Institute Research Corporation at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 24 Feb 2016. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Rate of non-fatal infarction or death in the normal group of SPECT-Light acquisitions versus standard SPECT acquisitions (time frame: 2 years). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT01412827, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Feb 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in