Myocardial InfarctionPhase 4EVERZOTANCT01347554
Efficacy of Everolimus-Eluting Versus Zotarolimus-Eluting Sten for Coronary Lesions in Acute Myocardial Infarction
A Phase 4 study testing Everolimus eluting stent and Zotarolimus eluting stent in people with Myocardial Infarction, run by Yonsei University at 1 site in South Korea.
Trial summary
Most of the previous data regarding the efficacy of the everolimus-eluting stent (EES) was derived from studies comparing EES with bare metal stent (BMS) or EES with paclitaxel-eluting (PES). Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Myocardial Infarction
- What is being tested?
- Everolimus eluting stent and Zotarolimus eluting stent
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 461 participants
- Where
- 1 siteSouth Korea
- Study dates
- Jan 2009to Mar 2013
- Phase
- Phase 4
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age > 18 years
- Chest pain duration more than 10 minutes
- At least on of the following criteria
- A. ECG change (T inversion, ST depression or ST elevation)
- B. Cardiac enzyme elevation more than upper normal limit
- Significant coronary artery stenosis (>50% by visual estimate)
- The patient or guardian agrees to the study
Who cannot join
- Stent thrombosis
- Left main disease
- Cardiogenic shock
- Cronic kidney disease or renal failure requiring hemodialysis
- History of bleeding diathesis or known coagulopathy
- Gastrointestinal or genitourinary bleeding within the prior 3 months
Show all 9Show fewer
- History of major surgery within 2 months
- Planned surgery requiring cessation of clopidogrel within 12 months of percutaneous coronary intervention (PCI)
- Serious patients whose life expectancy <1 year or severe infectious status
Trial locations and contacts
1 site in 1 country.
South Korea1 site
Yonsei University Wonju College of Medicine; Wonju Severance Christian Hospital
Wŏnju, 220-701
About this study
Official title: Comparison of the Efficacy of Everolimus-Eluting Versus Zotarolimus-Eluting Stent for Coronary Lesions in Acute Myocardial Infarction
Most of the previous data regarding the efficacy of the everolimus-eluting stent (EES) was derived from studies comparing EES with bare metal stent (BMS) or EES with paclitaxel-eluting (PES). Although sirolimus-eluting stents (SES) have been shown to be the most efficacious drug regarding inhibition of neointima and late loss, there have been no previous head to head comparisons between EES and zotarolimus-eluting stent (ZES). Both everolimus and sirolimus are macrocyclic lactones that target the mTOR (mammalian target of rapamycin) to reduce vascular smooth muscle proliferation after vessel injury and therefore in principle may show similar results after stenting in humans. Data pooled from the EES arm that received follow up angiography in the SPIRIT III trial and the SES arm in the SIRIUS trial show similar rates of binary restenosis and late loss. However, the stent and polymer platform is not the same between the EES and ZES and it is reported that the EES system has the thinnest stent + polymer thickness (88.6um) of all of the previously KFDA-approved drug-eluting stent (DES). In addition, there are no data available on the efficacy of the EES and ZES in "real world" lesions other than the selected lesions studied in the previous trials, such as acute myocardial infarction.
Read the detailed description
Previous randomized trials have shown the efficacy of a slow-release polymeric sirolimus-eluting stent (CYPHER, Cordis, Warren, NJ, USA), paclitaxel-eluting stent (TAXUS, Boston Scientific, Natick, MA, USA), and zotarolimus-eluting stent (Endeavor, Medtronic, Minneapolis, MN, USA) over bare metal stents in reducing neointimal hyperplasia, late luminal loss, and angiographic restenosis leading to decreased target lesion revascularization. The everolimus-eluting stent (XIENCE V, Abott Vascular, Santa Clara, CA, USA, PROMUS, Boston Scientific, Natick, MA, USA) is a newly developed drug eluting stent using the MULTILINK VISION® stent platform combined with the drug everolimus contained in a polymer coating.
In the first-in-man SPIRIT First clinical trial, XIENCE V showed a significant benefit over the bare metal VISION stent. Compared with late loss of 0.85 ± 0.36mm in the VISION arm, XIENCE V reduced late loss by 88% (0.10 ± 0.23mm). Also the clinical safety of XIENCE V was confirmed with a 6-month MACE rate of 7.7%. In the SPIRIT II clinical trial, which compared the efficacy and safety of the XIENCE V stent versus the TAXUS PECSS stent, the primary endpoint was met showing a non-inferiority of the XIENCE V compared with the TAXUS regarding in-stent late loss at 180 days. Actually, XIENCE V was superior to TAXUS and reduced in-stent late loss by 72% from a mean of 0.36 mm to 0.11 mm. In addition, analysis of other key clinical endpoints showed a lower rate of ischemia driven MACE (2.7% vs. 6.5% for XIENCE V vs. TAXUS) and protocol-defined stent thrombosis (0.5% vs. 1.3% for XIENCE V vs. TAXUS). The lower rate of ischemia driven MACE at 180 days was sustained through 1 year and there were no new instances of late stent thrombosis in either group up to 1 year.
The SPIRIT III RCT was a prospective, 2:1 randomized, active-controlled, single blinded, parallel, multi-center clinical evaluation of the XIENCE V Everolimus Eluting Coronary Stent System (XIENCE V EECSS) compared to TAXUS Paclitaxel Eluting Coronary Stent System (TAXUS PECSS) in the treatment of up to two de novo lesions. This pivotal clinical trial was designed to demonstrate the non-inferiority of the XIENCE V EECSS to the TAXUS PECSS. Patients were randomized 2:1 to XIENCE V or TAXUS and the primary endpoint was in-segment late loss at 240 days. The results showed a mean in-segment late loss of 0.14mm for XIENCE V and 0.28 mm for TAXUS (p<0.001 for non-inferiority, p=0.0037 for superiority). The secondary endpoint, which was ischemia-driven target vessel failure (TVF), was 7.6% for XIENCE V and 9.7% for TAXUS, confirming the non-inferiority of XIENCE V. Furthermore, the rate of definite and probable stent thrombosis was 1.1% and 0.6% for XIENCE V and TAXUS, respectively.
With a recent approval of new DES, zotarolimus-eluting stent (Endeavor, Medtronic, Minneapolis, MN), other comparison studies have been conducted to compare Endeavor zotarolimus-eluting stent with the sirolimus-eluting stent and paclitaxel-eluting stent. zotarolimus and sirolimus share some common structural and biological properties. In vitro data suggest that sirolimus and tetrazole containing rapamycin analogs have similar inhibitory effects in a mixed lymphocyte reaction assay. The ENDEAVOR clinical trials are currently in progress to evaluate a phosphoryl choline (PC)-coated zotarolimus-eluting stent(ZES) for the prevention of restenosis. The Endeavor zotarolimus-eluting stent utilizes a cobalt alloy balloon-expandable stent (Driver; Medtronic) with a geometry similar to the stainless steel stent used in this preliminary study (S7; Medtronic). The Endeavor ZES also employees a PC strut surface coating as the drug delivery reservoir with a dose of 10 g/mm of ABT-578. The Endeavor (ZES), however, differs from the stent used in this experimental study by the addition of a drug-free PC topcoat to serve as a diffusion barrier to retard drug release from the polymer reservoir. Angiographic analysis at 4 months in the 100-patient focal de novo lesion ENDEAVOR I feasibility study demonstrated a mean in-stent percent diameter stenosis of approximately 14% and a late lumen loss of 0.3 mm with a low frequency of target lesion revascularization (1%). The clinical outcomes from the ENDEAVOR II (1,500 patients randomized to ABT-578 or bare metal stent) and the ENDEAVOR III (436 patients randomized 3:1 to ABT-578 or Cypher) trials as well as other ongoing studies showed efficacy of the PC-coated ABT-578-eluting stent. In ENDEAVOR III study, the Endeavor stent had larger late loss and higher binary restenosis in both the analysis segment and stented segment.
Most of the previous data regarding the efficacy of the EES was derived from studies comparing EES with BMS or EES with PES. Although sirolimus eluting stents (SES) have been shown to be the most efficacious drug eluting stent regarding inhibition of neointima and late loss, there have been no previous head to head comparisons between EES and ZES. Both everolimus and sirolimus are macrocyclic lactones that target the mTOR (mammalian target of rapamycin) to reduce vascular smooth muscle proliferation after vessel injury and therefore in principle may show similar results after stenting in humans. Data pooled from the EES arm that received follow up angiography in the SPIRIT III trial and the SES arm in the SIRIUS trial show similar rates of binary restenosis and late loss. However, the stent and polymer platform is not the same between the EES and ZES and it is reported that the EES system has the thinnest stent + polymer thickness (88.6um) of all of the previously KFDA-approved DES. In addition, there are no data available on the efficacy of the EES and ZES in "real world" lesions other than the selected lesions studied in the previous trials, such as acute myocardial infarction.
- Conditions
- Myocardial Infarction
- Being tested
- Everolimus eluting stent, Zotarolimus eluting stent
- Keywords
- drug-eluting stent, everolimus, zotarolimus, myocardial ischemia, cardiovascular diseases, MACE, safety
- Medical subject headings
- Myocardial Infarction, Myocardial Ischemia, Cardiovascular Diseases
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Everolimus eluting stentDevice
Also called Xience V, Promus or Promus element
Comparison of the safety and efficacy between everolimus-eluting stent and zotarolimus-eluting stent resolute
Zotarolimus eluting stentDevice
Also called Endeavor resolute
Comparison of the safety and efficacy between everolimus-eluting stent and zotarolimus-eluting stent resolute
| Study group | Role | What they receive |
|---|---|---|
| Xience V stent group | Active comparator | Xience V (Everolimus eluting stent) insertion in patients with acute myocardial infarction Receives: Device: Everolimus eluting stent |
| Endeavor resolute group | Active comparator | Endeavor resolute (Zotarolimus eluting stent) insertion in patients with acute myocardial infarction Receives: Device: Zotarolimus eluting stent |
What is being measured
The primary outcome is the main question the study is designed to answer.
Device-oriented Composite Outcome
defined as a composite of cardiac death, Myocardial infarction not clearly attributable to a nontarget vessel and target lesion revascularization
Measured: Two year
Secondary outcomes (3)
Device-oriented Composite Outcome
defined as a composite of all-cause mortality, any MI (includes non-target vessel territory) and repeat revascularization (includes all target and non-target vessel)
Measured: Two years
Stent Thrombosis
Definite and probable stent thrombosis
Measured: Two years
Any Bleeding
Measured: Two year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted4 May 2011 (estimated)
- Study startJan 2009
- Primary completionMar 2013
- Study completionMar 2013
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Myocardial InfarctionStudies of the same condition, open and under way.
- More trials run by Yonsei UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 4
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 461 participants (actual)
Sponsor and investigators
- Lead sponsor
- Yonsei University
- Sponsor type
- University, hospital or other
- Collaborators
- Medtronic
- Responsible party
- Sponsor
- Investigators
- Seung-Hwan Lee, MD, PhD, Principal investigator, Division of Cardiology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, Wonju Severance Christian Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01347554
- Sponsor's protocol ID
- EVZT_2.0
- Acronym
- EVERZOTA
- Status last verified
- Sep 2014
- First submitted
- 27 Apr 2011
- Last updated
- 29 Sep 2014
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
Publications
Ahn SG, Choi HH, Lee JH, Lee JW, Youn YJ, Yoo SY, Cho BR, Lee SH, Yoon J. The impact of initial and residual thrombus burden on the no-reflow phenomenon in patients with ST-segment elevation myocardial infarction. Coron Artery Dis. 2015 May;26(3):245-53. doi: 10.1097/MCA.0000000000000197.
PubMed 25503419
Study at a glance
From the registry record, last updated by the sponsor on 29 Sep 2014. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparison of the Efficacy of Everolimus-Eluting Versus Zotarolimus-Eluting Stent for Coronary Lesions in Acute Myocardial Infarction
- ClinicalTrials.gov ID
- NCT01347554
- Acronym / sponsor ID
- EVERZOTA / EVZT_2.0
- Conditions
- Myocardial Infarction
- Keywords
- drug-eluting stent, everolimus, zotarolimus, myocardial ischemia, cardiovascular diseases, MACE, safety
- Phase
- Phase 4
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 461 participants (actual)
- Lead sponsor
- Yonsei UniversityUniversity, hospital or other
- Collaborators
- Medtronic
- Study start
- Jan 2009
- Primary completion
- Mar 2013 (actual)
- Study completion
- Mar 2013 (actual)
- First posted
- 4 May 2011 (estimated)
- Results
- Posted 29 Sep 2014
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Most of the previous data regarding the efficacy of the everolimus-eluting stent (EES) was derived from studies comparing EES with bare metal stent (BMS) or EES with paclitaxel-eluting (PES). Although sirolimus-eluting stents (SES) have been shown to be the most efficacious drug regarding inhibition of neointima and late loss, there have been no previous head to head comparisons between EES and zotarolimus-eluting stent (ZES). Both everolimus and sirolimus are macrocyclic lactones that target the mTOR (mammalian target of rapamycin) to reduce vascular smooth muscle proliferation after vessel injury and therefore in principle may show similar results after stenting in humans. Data pooled from the EES arm that received follow up angiography in the SPIRIT III trial and the SES arm in the SIRIUS trial show similar rates of binary restenosis and late loss. However, the stent and polymer platform is not the same between the EES and ZES and it is reported that the EES system has the thinnest stent + polymer thickness (88.6um) of all of the previously KFDA-approved drug-eluting stent (DES). In addition, there are no data available on the efficacy of the EES and ZES in "real world" lesions other than the selected lesions studied in the previous trials, such as acute myocardial infarction.
Detailed description
Previous randomized trials have shown the efficacy of a slow-release polymeric sirolimus-eluting stent (CYPHER, Cordis, Warren, NJ, USA), paclitaxel-eluting stent (TAXUS, Boston Scientific, Natick, MA, USA), and zotarolimus-eluting stent (Endeavor, Medtronic, Minneapolis, MN, USA) over bare metal stents in reducing neointimal hyperplasia, late luminal loss, and angiographic restenosis leading to decreased target lesion revascularization. The everolimus-eluting stent (XIENCE V, Abott Vascular, Santa Clara, CA, USA, PROMUS, Boston Scientific, Natick, MA, USA) is a newly developed drug eluting stent using the MULTILINK VISION® stent platform combined with the drug everolimus contained in a polymer coating.
In the first-in-man SPIRIT First clinical trial, XIENCE V showed a significant benefit over the bare metal VISION stent. Compared with late loss of 0.85 ± 0.36mm in the VISION arm, XIENCE V reduced late loss by 88% (0.10 ± 0.23mm). Also the clinical safety of XIENCE V was confirmed with a 6-month MACE rate of 7.7%. In the SPIRIT II clinical trial, which compared the efficacy and safety of the XIENCE V stent versus the TAXUS PECSS stent, the primary endpoint was met showing a non-inferiority of the XIENCE V compared with the TAXUS regarding in-stent late loss at 180 days. Actually, XIENCE V was superior to TAXUS and reduced in-stent late loss by 72% from a mean of 0.36 mm to 0.11 mm. In addition, analysis of other key clinical endpoints showed a lower rate of ischemia driven MACE (2.7% vs. 6.5% for XIENCE V vs. TAXUS) and protocol-defined stent thrombosis (0.5% vs. 1.3% for XIENCE V vs. TAXUS). The lower rate of ischemia driven MACE at 180 days was sustained through 1 year and there were no new instances of late stent thrombosis in either group up to 1 year.
The SPIRIT III RCT was a prospective, 2:1 randomized, active-controlled, single blinded, parallel, multi-center clinical evaluation of the XIENCE V Everolimus Eluting Coronary Stent System (XIENCE V EECSS) compared to TAXUS Paclitaxel Eluting Coronary Stent System (TAXUS PECSS) in the treatment of up to two de novo lesions. This pivotal clinical trial was designed to demonstrate the non-inferiority of the XIENCE V EECSS to the TAXUS PECSS. Patients were randomized 2:1 to XIENCE V or TAXUS and the primary endpoint was in-segment late loss at 240 days. The results showed a mean in-segment late loss of 0.14mm for XIENCE V and 0.28 mm for TAXUS (p<0.001 for non-inferiority, p=0.0037 for superiority). The secondary endpoint, which was ischemia-driven target vessel failure (TVF), was 7.6% for XIENCE V and 9.7% for TAXUS, confirming the non-inferiority of XIENCE V. Furthermore, the rate of definite and probable stent thrombosis was 1.1% and 0.6% for XIENCE V and TAXUS, respectively.
With a recent approval of new DES, zotarolimus-eluting stent (Endeavor, Medtronic, Minneapolis, MN), other comparison studies have been conducted to compare Endeavor zotarolimus-eluting stent with the sirolimus-eluting stent and paclitaxel-eluting stent. zotarolimus and sirolimus share some common structural and biological properties. In vitro data suggest that sirolimus and tetrazole containing rapamycin analogs have similar inhibitory effects in a mixed lymphocyte reaction assay. The ENDEAVOR clinical trials are currently in progress to evaluate a phosphoryl choline (PC)-coated zotarolimus-eluting stent(ZES) for the prevention of restenosis. The Endeavor zotarolimus-eluting stent utilizes a cobalt alloy balloon-expandable stent (Driver; Medtronic) with a geometry similar to the stainless steel stent used in this preliminary study (S7; Medtronic). The Endeavor ZES also employees a PC strut surface coating as the drug delivery reservoir with a dose of 10 g/mm of ABT-578. The Endeavor (ZES), however, differs from the stent used in this experimental study by the addition of a drug-free PC topcoat to serve as a diffusion barrier to retard drug release from the polymer reservoir. Angiographic analysis at 4 months in the 100-patient focal de novo lesion ENDEAVOR I feasibility study demonstrated a mean in-stent percent diameter stenosis of approximately 14% and a late lumen loss of 0.3 mm with a low frequency of target lesion revascularization (1%). The clinical outcomes from the ENDEAVOR II (1,500 patients randomized to ABT-578 or bare metal stent) and the ENDEAVOR III (436 patients randomized 3:1 to ABT-578 or Cypher) trials as well as other ongoing studies showed efficacy of the PC-coated ABT-578-eluting stent. In ENDEAVOR III study, the Endeavor stent had larger late loss and higher binary restenosis in both the analysis segment and stented segment.
Most of the previous data regarding the efficacy of the EES was derived from studies comparing EES with BMS or EES with PES. Although sirolimus eluting stents (SES) have been shown to be the most efficacious drug eluting stent regarding inhibition of neointima and late loss, there have been no previous head to head comparisons between EES and ZES. Both everolimus and sirolimus are macrocyclic lactones that target the mTOR (mammalian target of rapamycin) to reduce vascular smooth muscle proliferation after vessel injury and therefore in principle may show similar results after stenting in humans. Data pooled from the EES arm that received follow up angiography in the SPIRIT III trial and the SES arm in the SIRIUS trial show similar rates of binary restenosis and late loss. However, the stent and polymer platform is not the same between the EES and ZES and it is reported that the EES system has the thinnest stent + polymer thickness (88.6um) of all of the previously KFDA-approved DES. In addition, there are no data available on the efficacy of the EES and ZES in "real world" lesions other than the selected lesions studied in the previous trials, such as acute myocardial infarction.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Xience V stent group | Active comparator | Device: Everolimus eluting stentXience V (Everolimus eluting stent) insertion in patients with acute myocardial infarction |
| Endeavor resolute group | Active comparator | Device: Zotarolimus eluting stentEndeavor resolute (Zotarolimus eluting stent) insertion in patients with acute myocardial infarction |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (7 listed)
- Age > 18 years
- Chest pain duration more than 10 minutes
- At least on of the following criteria
- A. ECG change (T inversion, ST depression or ST elevation)
- B. Cardiac enzyme elevation more than upper normal limit
Key exclusion criteria (9 listed)
- Stent thrombosis
- Left main disease
- Cardiogenic shock
- Cronic kidney disease or renal failure requiring hemodialysis
- History of bleeding diathesis or known coagulopathy
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Everolimus eluting stentAlso: Xience V, Promus or Promus elementComparison of the safety and efficacy between everolimus-eluting stent and zotarolimus-eluting stent resolute | Device | Xience V stent group |
| Zotarolimus eluting stentAlso: Endeavor resoluteComparison of the safety and efficacy between everolimus-eluting stent and zotarolimus-eluting stent resolute | Device | Endeavor resolute group |
Primary outcome
Device-oriented Composite Outcome
Time frame: Two year
defined as a composite of cardiac death, Myocardial infarction not clearly attributable to a nontarget vessel and target lesion revascularization
3 secondary outcomes
Device-oriented Composite Outcome
Time frame: Two years
Stent Thrombosis
Time frame: Two years
Any Bleeding
Time frame: Two year
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 29 Sep 2014.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Derived from this study: PubMed 25503419Ahn SG, Choi HH, Lee JH, Lee JW, Youn YJ, Yoo SY, Cho BR, Lee SH, Yoon J. The impact of initial and residual thrombus burden on the no-reflow phenomenon in patients with ST-segment elevation myocardial infarction. Coron Artery Dis. 2015 May;26(3):245-53. doi: 10.1097/MCA.0000000000000197.
Related trials for Myocardial Infarction
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
Active, not recruitingObservational study
A Longitudinal Cohort Study to Evaluate Cardiovascular Risk Factors and Disease in Haiti
Hypertension, Diabetes
Active, not recruitingPhase 3
A Study of Inclisiran to Prevent Cardiovascular Events in High-risk Primary Prevention Patients.
Primary Prevention of Atherosclerotic Cardiovascular Disease
Enrolling by invitation
The DANE-HEART Trial - Computed Tomography Coronary Angiography for Primary Prevention
Coronary Atherosclerosis and Other Heart Disease, Cardiovascular Diseases
Not yet recruitingObservational study
Elicit Drugs in Myocardial Infarction
Young Patients With Acute Myocardial Infarction
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Seung-Hwan Lee, MD, PhD principal investigator
Division of Cardiology, Department of Internal Medicine, Yonsei University Wonju College of Medicine, Wonju Severance Christian Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 4 study testing Everolimus eluting stent and Zotarolimus eluting stent in people with Myocardial Infarction, run by Yonsei University at 1 site in South Korea.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 7 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 29 Sep 2014. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
Yes. Results are posted in the registry (first posted 29 Sep 2014). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Device-oriented Composite Outcome (time frame: Two year). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01347554, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Sep 2014.