AzTrials
AzTrials

Anesthetized Ventilated PatientsPuTT-NICOMNCT01259687

Pulse Transit Time in Anesthetized Patients: Blood Pressure or Cardiac Output as Measured With NICOM Monitor

An observational study of Anesthetized Ventilated Patients, run by Carmel Medical Center at 2 sites in Israel.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Pulse transit time (PuTT) - the time between R wave on ECG and initiation of upstroke in the peripheral arterial waveform - described in the previous studies as value that reflects changes in both blood pressure and blood volume. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Anesthetized Ventilated Patients
What is being tested?
Non-invasive cardiac output monitoring
Type of treatment
Medical device
How many people
63 participants
Where
2 sitesIsrael
Study dates
Jan 2011to Nov 2013
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients undergoing various types elective surgery which require continous invasive monitoring of blod pressure

Who may be able to join

  • All patients scheduled for elective surgery and require invasive monitoring of blood pressure according to their medical condition and type of surgery

Who cannot join

  • Patients under the age of 18

Trial locations and contacts

2 sites in 1 country.

Israel2 sites
  • Carmel Medical Center

    Haifa, 34362

  • The Lady Davis Carmel Medical Center

    Haifa, 34382

Other trials in Israel

About this study

Official title: Pulse Transit Time in Anesthetized Ventilated Patients: Affect of Blood Pressure or Cardiac Output as Measured With NICOM Monitor

Pulse transit time (PuTT) - the time between R wave on ECG and initiation of upstroke in the peripheral arterial waveform - described in the previous studies as value that reflects changes in both blood pressure and blood volume. The investigators are assuming that PuTT changes reflect the dynamic of systolic blood pressure but not cardiac output fluctuations.

Read the detailed description

Background Pulse transit time (PuTT) - the time between R wave on ECG and initiation of upstroke in the peripheral arterial waveform - described in the previous studies as value that reflects changes in both blood pressure and blood volume. We are assuming that PuTT changes reflect the dynamic of systolic blood pressure but not cardiac output fluctuations.

Clinical trial objectives Investigate a link between PuTT (Pulse transit time) and changes in blood pressure and cardiac output measured by non-invasive cardiac output monitoring device (NICOM).

Endpoints PuTT Blood pressure: systolic, diastolic, mean Heart rate Cardiac output-Index Systemic vascular resistance-Index

Prospective nonrandomized clinical trial

Inclusion criteria Need for continuous invasive monitoring of blood pressure - according to the type of surgery the patient's health status Normal sinus rhythm

Exclusion criteria Pregnancy Cave to Nitroglycerine or Phenylephrine Chronic renal failure with creatinine level above 2 mg%

Safety assessment methods Monitoring of cardiac output is one of the most important elements of hemodynamic monitoring. In the past this monitoring was based mainly on the invasive and awkward methods causing usage only in exceptional cases. NICOM device allows accurate non-invasive monitoring of cardiac output During anesthesia patient care changes are made according to changes in vital indicators such as blood pressure, pulse, cardiac output. So during the study, anesthesia care can be affected by the indices obtained using a NICOM.

Data processing and analysis During the surgery the continuous monitoring of blood pressure by peripheral artery catheter and cardiac output by NICOM will be applied.

In case of hemodynamic changes the patient will be treated according to the standard care:

In case of decrease of systolic blood pressure below 80 mmHg (in the patients with history of arterial hypertension - below 90 mmHg) and HR is above 70 bpm the patient will be treated by repeated boluses of Phenylephrine 50-100 mcg until the systolic blood pressure will increase by at least 20%.

Intraoperative hypertension above 160 mmHg will be treated by repeated boluses of Nitroglycerine 100 mcg until the systolic blood pressure will decrease by at least 20%.

Hypovolemia will be treated by boluses of colloid solution - HAES 6% - at dose of 7 ml/kg of body mass during 15 min.

Study procedures

Cardiac output will be measured by NICOM just before and after each treatment of hemodynamic events that described above. Simultaneous records of ECG, arterial and plethysmographic waveforms will be made just before and after each event.

Systolic blood pressure and PuTT will be measured OFFLINE from the recorded waveforms.

Being tested
Non-invasive cardiac output monitoring
Keywords
Electrocardiogram, Arterial line waveform, Cardiac output

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Non-invasive cardiac output monitoringDevice

    Also called Cheetah Reliant, NICOM, Cheetah Medical

    During the surgery the continuous monitoring of blood pressure by peripheral artery catheter and cardiac output by NICOM (non-invasive cardiac output monitoring) will be applied. In case of intraoperative hemodynamic changes (hypertension, hypotension) the patient will be treated according to the standard care by Phenylephrine, Nitroglycerine or Colloid fluid boluses. Cardiac output will be measured by NICOM just before and after each treatment of hemodynamic events that described above. Simultaneous records of ECG, arterial and plethysmographic waveforms will be made just before and after each event. Systolic blood pressure and PuTT will be measured OFFLINE from the recorded waveforms

Study groups in NCT01259687
Study groupRoleWhat they receive
Study groupNot described
Receives: Device: Non-invasive cardiac output monitoring

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Pulse transit time (PuTT)

    Simultaneous record of arterial line waveform and ECG will be made just before and 2 minute after giving one of treatments (Phenylephrine, Nitroglycerine or fluid bolus). PuTT will be measured offline from the record

    Measured: Two minutes after each intervention (giving Nitroglycerine, Phenylephrine or Fluid loading)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Dec 2010 (estimated)
  2. Study startJan 2011
  3. Primary completionNov 2013
  4. Study completionNov 2013

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
63 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01259687
Sponsor's protocol ID
CMC-09-0124-CTIL
Acronym
PuTT-NICOM
Status last verified
Nov 2013
First submitted
7 Dec 2010
Last updated
26 Nov 2013
Results posted
No
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

An observational study of Anesthetized Ventilated Patients, run by Carmel Medical Center at 2 sites in Israel.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 26 Nov 2013. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Israel. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Pulse transit time (PuTT) (time frame: Two minutes after each intervention (giving Nitroglycerine, Phenylephrine or Fluid loading)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Nov 2013.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in