Prostate CancerVitesseNCT01248741

CT-validation of Ultrasound Based Planning for High Dose Rate (HDR) Prostate Brachytherapy Using Vitesse

A study testing HDR prostate brachytherapy in people with Prostate Cancer and Interstitial Radiation, run by British Columbia Cancer Agency at 1 site in Canada.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

High Dose Rate (HDR) temporary prostate brachytherapy offers a precise form of dose escalation for prostate cancer. Needles are placed, the position is confirmed and treatment is delivered. Read more about this study

Who is it for?
Ages 45 to 80 years, men only
What is being tested?
HDR prostate brachytherapy
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteCanada
Study dates
Dec 2010to May 2012
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 45 to 80 years
  • Men only
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients must have histologically proven adenocarcinoma of the prostate.
  • Patients must have intermediate risk prostate cancer. (Clinical stage ≤ T2c, Gleason score = 7 and initial prostate specific antigen (iPSA) ≤ 20, or Gleason score ≤ 6 and iPSA > 10 and ≤ 20.
  • Patients must be fit for general or spinal anaesthetic.
  • Patients must have an estimated life expectancy of at least 10 years.
  • Patients must have an Eastern Cooperative Oncology Group (ECOG) performance status of 0 - 2.
  • Patients must have no contraindications to interstitial prostate brachytherapy.
  • Patients on coumadin therapy must be able to stop therapy safely for at least 7 days.

Who cannot join

  • Men not able to fully understand the trial and the informed consent document
  • Men suffering from claustrophobia and unable to have a Computed Tomography scan
  • Men not wishing to have a cone-beam Computed Tomography scan following the insertion of the High Dose Rate brachytherapy needles to verify the accuracy of the treatment plan
  • Men who cannot safely discontinue blood thinners for a few days.

Trial locations and contacts

1 site in 1 country.

Canada1 site
  • BCCA Center for the Southern Interior

    Kelowna, British Columbia, V1Y 5L3

Other trials in Canada

About this study

Official title: High Dose Rate (HDR)Prostate Brachytherapy With Vitesse tm

High Dose Rate (HDR) temporary prostate brachytherapy offers a precise form of dose escalation for prostate cancer. Needles are placed, the position is confirmed and treatment is delivered. Previously High Dose Rate prostate brachytherapy was performed under TransRectal UltraSound (TRUS) guidance but planned with Computed Tomography (CT) imaging which introduced a source of error through needle displacement while transporting and repositioning patient. Recently Varian has introduced a one-step procedure where both implant and planning are based on UltraSound imaging and performed without patient repositioning. This planning system is approved by Health Canada and is commercially available.

This study will use High Dose Rate brachytherapy to treat 20 men. Treatment will be planned with TransRectal UltraSound and validated using Computed Tomography imaging.

Read the detailed description

Twenty men with intermediate risk prostate cancer, suitable for the combination of external beam radiotherapy and High Dose Rate brachytherapy will be entered in this study. High Dose Rate brachytherapy will be performed using TransRectal UltraSound guidance and then planned using both cone-beam Computed Tomography and TransRectal UltraSound. Planning by Computed Tomography is to check the reliability and reproducibility of UltraSound imaging to correctly identify the needle positions. Correct needle localization is essential because this is the basis for determining source dwell positions, dose calculation and dose optimization.

Being tested
HDR prostate brachytherapy
Keywords
prostate cancer, interstitial radiation,, brachytherapy
Medical subject headings
Prostatic Neoplasms

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • HDR prostate brachytherapyRadiation

    HDR prostate brachytherapy to be delivered in 2 fractions of 10 Gray as a "boost" combined with external beam radiotherapy

Study groups in NCT01248741
Study groupRoleWhat they receive
HDR prostate brachytherapyExperimentalAn array of 17 gauge steel needles, 20 cm in length, is inserted under Ultrasound (US) guidance into the prostate and advanced to the base of the prostate. A template is used to maintain spacing and parallelism and the needles are individually locked into the template once positioned. A continuously acquired set of US images is obtained for treatment planning purposes. Each needle is connected to a Varisource afterloader and treatment is delivered using a 10 Curie Iridium-192 source. The needles are then removed.
Receives: Radiation: HDR prostate brachytherapy

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of Needle Tip Identification on TransRectal UltraSound Compared to Computed Tomography

    Precise location of the tip of each needle in 3-dimensional space relative to the prostate determines the pattern of dose delivery. Inaccuracies in needle tip location may lead to differences detected between UltraSound(US)-based and Computed Tomography (CT)-based plans.The distance of the needle tip (as identified on either CT images or US images) protruding beyond the template was measured in mm. The template acted as a fixed reference point as it was locked into the stabilizer/stepper apparatus. The 2 protrusion readings for each needle tip were compared, the difference recorded in mm, and categorized as < 1 mm, 1-2 mm, 2-3 mm and > 3 mm.

    Measured: Treatment was planned and delivered based on ultrasound identification of needles and needle tips relative to prostate. All measurements and comparisons of measurements pertain to the day of the procedure.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Nov 2010 (estimated)
  2. Study startDec 2010
  3. Primary completionApr 2012
  4. Study completionMay 2012

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT01248741
Sponsor's protocol ID
H10-01987
Acronym
Vitesse
Status last verified
Nov 2020
First submitted
3 Nov 2010
Last updated
11 Dec 2020
Data monitoring committee
No

Questions about this trial

What is this clinical trial studying?

A study testing HDR prostate brachytherapy in people with Prostate Cancer and Interstitial Radiation, run by British Columbia Cancer Agency at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 11 Dec 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 11 Dec 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of Needle Tip Identification on TransRectal UltraSound Compared to Computed Tomography (time frame: Treatment was planned and delivered based on ultrasound identification of needles and needle tips relative to prostate. All measurements and comparisons of measurements pertain to the day of the procedure.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Dec 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in