Chronic Heart FailureENDURANCENCT01166347
The HeartWare™ Ventricular Assist System as Destination Therapy of Advanced Heart Failure: the ENDURANCE Trial
A study testing HeartWare® VAS in people with Chronic Heart Failure, run by Medtronic Cardiac Rhythm and Heart Failure at 48 sites in United States.
Trial summary
The purpose of this study is to determine the safety and effectiveness of the HeartWare Ventricular Assist System in patients with chronic Stage D/ New York Heart Association (NYHA) Class IIIB/IV left ventricular failure who have received and failed optimal medical therapy, and who are ineligible for cardiac… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Chronic Heart Failure
- What is being tested?
- HeartWare® VAS
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 451 participants
- Where
- 48 sitesUnited States
- Study dates
- Aug 2010to May 2017
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Must be ≥18 years of age at consent
- Body Surface Area (BSA) ≥ 1.2 m2
- Patients with advanced heart failure symptoms (New York Heart Association (NYHA) Class IIIB or IV) who are: (patient must meet one of the following) 3a. On optimal medical management, including dietary salt restriction and diuretics, for at least 45 out of the last 60 days and are failing to respond; or 3b. In NYHA Class III or NYHA Class IV heart failure for at least 14 days, and dependent on intra aortic balloon pump (IABP) for 7 days and/or inotropes for at least 14 days
- Left ventricular ejection fraction ≤ 25%
- LVAD implant is intended as destination therapy
- Must be able to receive either the HeartWare® VAS or control LVAD
- Female patients of childbearing potential must agree to use adequate contraceptive precautions for the duration of the study.
- The patient or legally authorized representative has signed the informed consent form
Who cannot join
- Body Mass Index (BMI) > 40
- Existence of any ongoing mechanical circulatory support (MCS) other than an intra-aortic balloon pump (IABP)
- Prior cardiac transplant.
- History of confirmed, untreated abdominal or thoracic aortic aneurysm > 5 cm.
- Cardiothoracic surgery within 30 days of randomization.
- Acute myocardial infarction within 14 days of implant
Show all 28Show fewer
- Patients eligible for cardiac transplantation
- On ventilator support for > 72 hours within the four days immediately prior to randomization and implant.
- Pulmonary embolus within three weeks of randomization
- Symptomatic cerebrovascular disease, stroke within 180 days of randomization or > 80% stenosis of carotid or cranial vessels.
- Uncorrected moderate to severe aortic insufficiency. Correction may include repair or bioprosthesis at the time of implant.
- Severe right ventricular failure as defined by the anticipated need for right ventricular assist device (RVAD) support or extracorporeal membrane oxygenation (ECMO) or right atrial pressure > 20 mmHg on multiple inotropes, right ventricular ejection fraction (RVEF) <15% or clinical signs
- Active, uncontrolled infection diagnosed by a combination of clinical symptoms and laboratory testing.
- Uncorrected thrombocytopenia or generalized coagulopathy (e.g., platelet count < 75,000, INR > 2.0 or PTT > 2.5 times control in the absence of anticoagulation therapy).
- Intolerance to anticoagulant or antiplatelet therapies or any other peri- or postoperative therapy that the investigator may administer based upon the patient's health status.
- Serum creatinine > 3.0 mg/dL within 72 hours of randomization or requiring dialysis (does not include use of ultra-filtration for fluid removal).
- Specific liver enzymes [AST (SGOT) and ALT (SGPT)] > 3 times upper limit of normal within 72 hours of randomization.
- A total bilirubin > 3 mg/dl within 72 hours of randomization, or biopsy proven liver cirrhosis or portal hypertension.
- Pulmonary vascular resistance (PVR) is demonstrated to be unresponsive to pharmacological manipulation and the PVR > 6 Wood units.
- Patients with a mechanical heart valve .
- Etiology of heart failure is due to, or associated with, uncorrected thyroid disease, obstructive cardiomyopathy, pericardial disease, amyloidosis, active myocarditis or restrictive cardiomyopathy
- History of severe Chronic Obstructive Pulmonary Disease (COPD) or severe restrictive lung disease
- Participation in any other study involving investigational drugs or devices
- Severe illness, other than heart disease, which would limit survival to < 3 years
- Peripheral vascular disease with rest pain or ischemic ulcers of the extremities
- Pregnancy
- Patient unwilling or unable to comply with study requirements
- Technical obstacles, which pose an inordinately high surgical risk, in the judgment of the investigator
Trial locations and contacts
48 sites in 1 country.
48 sites in 1 country
United States48 sites
University of Michigan Hospital
Ann Arbor, Michigan, 48109
The Emory Clinic Inc.
Atlanta, Georgia, 30322
Saint Joseph Hospital of Atlanta
Atlanta, Georgia, 30342
University of Colorado Hospital - Leprino
Aurora, Colorado, 80045
University of Maryland
Baltimore, Maryland, 21201
The University of Alabama at Birmingham
Birmingham, Alabama, 35294
Tufts Medical Center
Boston, Massachusetts, 02111
Northwestern Memorial Hospital
Chicago, Illinois, 60611
University of Chicago
Chicago, Illinois, 60637
Cleveland Clinic Foundation
Cleveland, Ohio, 44195
Ohio State University Medical Center
Columbus, Ohio, 43210
Baylor University Medical Center
Dallas, Texas, 75246
University of Texas - South Western
Dallas, Texas, 75390
Henry Ford Hospital
Detroit, Michigan, 48202
Duke University Medical Center
Durham, North Carolina, 27710
Innova Heart and Vascular Institute Research - Cardiac Vascular & Thoracic Surgery Associates, PC
Falls Church, Virginia, 22042
University of Florida - Gainesville
Gainesville, Florida, 32610
Milton S. Hershey Medical Center
Hershey, Pennsylvania, 17033
Texas Heart Institute
Houston, Texas, 77030
The Methodist Hospital
Houston, Texas, 77030
IU Health Methodist
Indianapolis, Indiana, 46202
Saint Vincent Health
Indianapolis, Indiana, 46260
The University of Southern California
Los Angeles, California, 90033
Jewish Hospital
Louisville, Kentucky, 40202
University of Miami/Jackson Memorial Hospital
Miami, Florida, 33136
Saint Luke's Medical Center
Milwaukee, Wisconsin, 53215
Abbott Northwestern
Minneapolis, Minnesota, 55407
University of Minnesota
Minneapolis, Minnesota, 55455
Intermountain Medical Center
Murray, Utah, 84107
John Ochsner Heart & Vascular Institute
New Orleans, Louisiana, 70115
New York Presbyterian Hospital/Columbia
New York, New York, 10032
Newark Beth Israel Medical Center
Newark, New Jersey, 07112
Sentara Norfolk
Norfolk, Virginia, 23507
Advocate Christ Medical Center
Oak Lawn, Illinois, 60453
University of Pennsylvania Hospital
Philadelphia, Pennsylvania, 19104
Mayo Clinic Hospital - Phoenix
Phoenix, Arizona, 85054
UPMC Presbyterian
Pittsburgh, Pennsylvania, 15213
Oregon Health & Science University
Portland, Oregon, 97239
St. Mary's Hospital - Mayo
Rochester, Minnesota, 55902
University of Utah
Salt Lake City, Utah, 84132
Sharp Memorial
San Diego, California, 92123
University of Washington Medical Center
Seattle, Washington, 98195
Northwest Cardiothoracic &Transplant Surgeons
Spokane, Washington, 99204
Washington University/Barnes-Jewish Hospital
St Louis, Missouri, 63110
Stanford University School of Medicine
Stanford, California, 94305
Tampa Transplant Institute/Tampa General Hospital
Tampa, Florida, 33606
Montefiore Medical Center
The Bronx, New York, 10467
Washington Hospital Center
Washington D.C., District of Columbia, 20010
About this study
Official title: A Prospective, Randomized, Controlled, Un-blinded, Multi-Center Clinical Trial to Evaluate the HeartWare™ Ventricular Assist System (VAS) for Destination Therapy of Advanced Heart Failure
The purpose of this study is to determine the safety and effectiveness of the HeartWare Ventricular Assist System in patients with chronic Stage D/ New York Heart Association (NYHA) Class IIIB/IV left ventricular failure who have received and failed optimal medical therapy, and who are ineligible for cardiac transplantation.
Read the detailed description
The HeartWare Ventricular Assist System (VAS) is intended for use in patients with chronic Stage D/NYHA Class IIIB/IV left ventricular failure who have received and failed optimal medical therapy and who are ineligible for cardiac transplantation. The ENDURANCE clinical study is a prospective, randomized, unblinded, multi-center, non-inferiority evaluation of the HeartWare® VAS versus a control group consisting of any FDA-approved Left Ventricular Assist Device (LVAD) approved for destination therapy. Patients are randomized to HeartWare® VAS or control LVAD in a 2:1 ratio. Each patient receiving the HeartWare® VAS or control LVAD is followed to the primary endpoint at 2 years, with a subsequent follow-up period extending to 5 years post implant.
- Conditions
- Chronic Heart Failure
- Being tested
- HeartWare® VAS, Control LVAD
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
HeartWare® VASDevice
The HeartWare® VAS is an implantable centrifugal pump that was designed to provide flows up to 10 L/min in a small device that is both lightweight and simple to use.
Control LVADDevice
Any FDA-approved LVAD for destination therapy.
| Study group | Role | What they receive |
|---|---|---|
| HeartWare® VAS | Experimental | Implant of HeartWare® Ventricular Assist System Receives: Device: HeartWare® VAS |
| Control LVAD | Active comparator | Implant of FDA-approved LVADs approved for destination therapy Receives: Device: Control LVAD |
What is being measured
The primary outcome is the main question the study is designed to answer.
Stroke-Free Survival Probability for 2 Years Post Implant
The primary endpoint of the trial is stroke-free survival at two years, defined as alive on the originally implanted device, electively transplanted or explanted due to patient recovery and free from disabling stroke (Modified Rankin Scale >=4). The Modified Rankin Scale is scored from 0 to 6, where 0 indicates an absence of symptoms and 6 indicates death. A score of 4 or higher indicates moderately severe or greater disability. Weibull model estimates of survival probability (shown as a percent of 100) are used.
Measured: Implant to 2 years
Secondary outcomes (12)
Number of Participants With Bleeding
Number of participants with bleeding, per Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) definition. The event of bleeding is defined as: An episode of suspected internal or external bleeding that results in one or more of the following:
- Death,
- Re-operation,
- Hospitalization,
- Transfusion of red blood cells as follows:
During first 7 days post implant
- Adults (≥ 50 kg): ≥ 4U packed red blood cells (PRBC) within any 24 hour period during first 7 days post implant.
After 7 days post implant
- Any transfusion of packed red blood cells (PRBC) after 7 days following implant.
Measured: Implant to two years
Number of Participants With Major Infections
Number of participants with major infections, per INTERMACS definition. A major infection is defined as: A clinical infection accompanied by pain, fever, drainage and/or leukocytosis that is treated by anti-microbial agents (non-prophylactic). A positive culture from the infected site or organ should be present unless strong clinical evidence indicates the need for treatment despite negative cultures. The general categories of infection include Localized non-device infection Percutaneous site and/or pocket infection Internal pump component, inflow or outflow tract infection Sepsis
Measured: Implant to two years
Overall Survival at 2 Years
Overall survival is the probability (expressed as a percent of 100) did not died within 2 years post implant via the Kaplan-Meier method. Participants that did not died were censored at the time of last follow-up or 2 years post implant, whichever occurred first.
Measured: Implant to two years
Number of Participants With Device Malfunctions
Number of Participants with device malfunctions per INTERMACS definition. Device malfunction denotes a failure of one or more of the components of the Mechanical Circulatory Support Device (MCSD) system which either directly causes or could potentially induce a state of inadequate circulatory support (low cardiac output state) or death. The manufacturer must confirm device failure. A failure that was iatrogenic or recipient-induced will be classified as an Iatrogenic/Recipient-Induced Failure.
Device failure should be classified according to which components fails as follows:
- Pump failure (blood contacting components of pump and any motor or other pump actuating mechanism that is housed with the blood contacting components).
- Non-pump failure (e.g., external pneumatic drive unit, electric power supply unit, batteries, controller, interconnect cable, compliance chamber)
Measured: Implant to two years
Health Status Change Measured by Kansas City Cardiomyopathy Questionnaire (KCCQ)
Health Status change as measured by Kansas City Cardiomyopathy Questionnaire (KCCQ) Overall Summary Score. The KCCQ is a disease-specific patient-reported outcomes measure for patients with heart failure. It consists of 23 items, is comprised of 7 clinically relevant scales (Symptom Frequency, Symptom Burden, Symptom Stability, Physical Limitation, Social Limitation, Quality of Life, and Self-Efficacy), and yields 3 summary scores (Clinical Summary, Total Symptom, and Overall Summary Scores). Scale and summary scores range between 0 and 100, with higher scores indicating better health status (e.g., better functioning, fewer symptoms, better quality of life). The Overall Summary Score is calculated as the mean of the Physical Limitation, Total Symptom, Quality of Life and Social Limitation scores. A positive change in score from baseline indicates an improvement.
Measured: Change from baseline to 2 years
Health Status Change Measured by EuroQol EQ-5D (Version 3L)
The EuroQol-5D (version 3L) is a brief self-administered, validated instrument consisting of 2 parts. The second part consists of the EQ-5D general health status as measured by a visual analog scale (EQ-5D VAS). EQ-5D VAS measures the participant's self-rated health status on a scale from 0 (worst imaginable health state) to 100 (best imaginable health state). An adjustment was done on the response where the scores were normalized based on this paper: Johnson JA, Coons SJ. Comparison of the EQ-5D and SF-12 in an adult US sample. Qual Life Res. 1998 Feb;7(2):155-66.
Measured: Change from baseline to 2 years
Change in Functional Status Measured by New York Heart Association (NYHA) Class
Change in Functional status, as measured by New York Heart Association (NYHA) class. There are 4 levels of NYHA:
I (Mild): No limitation of physical activity. Ordinary physical activity does not cause undue fatigue, palpitation, or dyspnea.
II (Mild): Slight limitation of physical activity. Comfortable at rest, but ordinary physical activity results in fatigue, palpitation, or dyspnea.
III (Moderate): Marked limitation of physical activity. Comfortable at rest, but less than ordinary activity causes fatigue, palpitation, or dyspnea.
IV (Severe): Unable to carry out any physical activity without discomfort. Symptoms of cardiac insufficiency at rest. If any physical activity is undertaken, discomfort is increased. Improvement is defined as moving from a higher numerical NYHA level to a lower numerical NYHA level (e.g., IV to III).
Measured: Change from baseline to 2 years
Change in Functional Status as Measured by 6-minute Walk
Change in functional status, as measured by 6-minute walk test.
Measured: Change from baseline to 2 years
Length of Initial Hospitalization
Length of Initial Hospitalization post implant
Measured: Implant to the end of the initial hospitalization
Number of Participants Who Had a Re-hospitalization
Number of participants who had a re-hospitalization while on the device
Measured: Implant to two years
Duration of Re-hospitalization
Duration of Re-hospitalization while on device
Measured: Implant to two years
Cause of Re-hospitalization
Cause of Re-hospitalization while on device. The reason a participant may have been re-hospitalized was due to an adverse event, the need for an explant, or for various "Other" reasons.
Measured: Implant to two years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted21 Jul 2010 (estimated)
- Study startAug 2010
- Primary completionMay 2014
- Study completionMay 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (3)Papers the sponsor has linked to this study.
- Other trials for Chronic Heart FailureStudies of the same condition, open and under way.
- More trials run by Medtronic Cardiac Rhythm and Heart FailureThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 451 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medtronic Cardiac Rhythm and Heart Failure
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Francis Pagani, MD, Principal investigator, University of Michigan HospitalJoseph Rogers, MD, Principal investigator, Duke University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01166347
- Sponsor's protocol ID
- HW004 ENDURANCE
- Acronym
- ENDURANCE
- Status last verified
- Sep 2018
- First submitted
- 16 Jul 2010
- Last updated
- 6 Sep 2018
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
Publications
Rogers JG, Pagani FD, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, Boyce SW, Najjar SS, Jeevanandam V, Anderson AS, Gregoric ID, Mallidi H, Leadley K, Aaronson KD, Frazier OH, Milano CA. Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure. N Engl J Med. 2017 Feb 2;376(5):451-460. doi: 10.1056/NEJMoa1602954.
PubMed 28146651Mahr C, McGee E Jr, Cheung A, Mokadam NA, Strueber M, Slaughter MS, Danter MR, Levy WC, Cheng RK, Beckman JA, May DM, Ismyrloglou E, Tsintzos SI, Silvestry SC. Cost-Effectiveness of Thoracotomy Approach for the Implantation of a Centrifugal Left Ventricular Assist Device. ASAIO J. 2020 Aug;66(8):855-861. doi: 10.1097/MAT.0000000000001209.
PubMed 32740343Silvestry SC, Mahr C, Slaughter MS, Levy WC, Cheng RK, May DM, Ismyrloglou E, Tsintzos SI, Tuttle E, Cook K, Birk E, Gomes A, Graham S, Cotts WG. Cost-Effectiveness of a Small Intrapericardial Centrifugal Left Ventricular Assist Device. ASAIO J. 2020 Aug;66(8):862-870. doi: 10.1097/MAT.0000000000001211.
PubMed 32740129
Study at a glance
From the registry record, last updated by the sponsor on 6 Sep 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Prospective, Randomized, Controlled, Un-blinded, Multi-Center Clinical Trial to Evaluate the HeartWare™ Ventricular Assist System (VAS) for Destination Therapy of Advanced Heart Failure
- ClinicalTrials.gov ID
- NCT01166347
- Acronym / sponsor ID
- ENDURANCE / HW004 ENDURANCE
- Conditions
- Chronic Heart Failure
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 451 participants (actual)
- Lead sponsor
- Medtronic Cardiac Rhythm and Heart FailureIndustry (pharma, biotech, devices)
- Study start
- Aug 2010
- Primary completion
- May 2014 (actual)
- Study completion
- May 2017 (actual)
- First posted
- 21 Jul 2010 (estimated)
- Results
- Posted 28 Feb 2018
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to determine the safety and effectiveness of the HeartWare Ventricular Assist System in patients with chronic Stage D/ New York Heart Association (NYHA) Class IIIB/IV left ventricular failure who have received and failed optimal medical therapy, and who are ineligible for cardiac transplantation.
Detailed description
The HeartWare Ventricular Assist System (VAS) is intended for use in patients with chronic Stage D/NYHA Class IIIB/IV left ventricular failure who have received and failed optimal medical therapy and who are ineligible for cardiac transplantation. The ENDURANCE clinical study is a prospective, randomized, unblinded, multi-center, non-inferiority evaluation of the HeartWare® VAS versus a control group consisting of any FDA-approved Left Ventricular Assist Device (LVAD) approved for destination therapy. Patients are randomized to HeartWare® VAS or control LVAD in a 2:1 ratio. Each patient receiving the HeartWare® VAS or control LVAD is followed to the primary endpoint at 2 years, with a subsequent follow-up period extending to 5 years post implant.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| HeartWare® VAS | Experimental | Device: HeartWare® VASImplant of HeartWare® Ventricular Assist System |
| Control LVAD | Active comparator | Device: Control LVADImplant of FDA-approved LVADs approved for destination therapy |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (8 listed)
- Must be ≥18 years of age at consent
- Body Surface Area (BSA) ≥ 1.2 m2
- Patients with advanced heart failure symptoms (New York Heart Association (NYHA) Class IIIB or IV) who are: (patient must meet one of the following) 3a. On optimal medical management, including dietary salt restriction and diuretics, for at least 45 out of the last 60 days and are failing to respond; or 3b. In NYHA Class III or NYHA Class IV heart failure for at least 14 days, and dependent on intra aortic balloon pump (IABP) for 7 days and/or inotropes for at least 14 days
- Left ventricular ejection fraction ≤ 25%
- LVAD implant is intended as destination therapy
Key exclusion criteria (28 listed)
- Body Mass Index (BMI) > 40
- Existence of any ongoing mechanical circulatory support (MCS) other than an intra-aortic balloon pump (IABP)
- Prior cardiac transplant.
- History of confirmed, untreated abdominal or thoracic aortic aneurysm > 5 cm.
- Cardiothoracic surgery within 30 days of randomization.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| HeartWare® VASThe HeartWare® VAS is an implantable centrifugal pump that was designed to provide flows up to 10 L/min in a small device that is both lightweight and simple to use. | Device | HeartWare® VAS |
| Control LVADAny FDA-approved LVAD for destination therapy. | Device | Control LVAD |
Primary outcome
Stroke-Free Survival Probability for 2 Years Post Implant
Time frame: Implant to 2 years
The primary endpoint of the trial is stroke-free survival at two years, defined as alive on the originally implanted device, electively transplanted or explanted due to patient recovery and free from disabling stroke (Modified Rankin Scale >=4). The Modified Rankin Scale is scored from 0 to 6, where 0 indicates an absence of symptoms and 6 indicates death. A score of 4 or higher indicates moderately severe or greater disability. Weibull model estimates of survival probability (shown as a percent of 100) are used.
12 secondary outcomes
Number of Participants With Bleeding
Time frame: Implant to two years
Number of Participants With Major Infections
Time frame: Implant to two years
Overall Survival at 2 Years
Time frame: Implant to two years
Number of Participants With Device Malfunctions
Time frame: Implant to two years
Health Status Change Measured by Kansas City Cardiomyopathy Questionnaire (KCCQ)
Time frame: Change from baseline to 2 years
Health Status Change Measured by EuroQol EQ-5D (Version 3L)
Time frame: Change from baseline to 2 years
Change in Functional Status Measured by New York Heart Association (NYHA) Class
Time frame: Change from baseline to 2 years
Change in Functional Status as Measured by 6-minute Walk
Time frame: Change from baseline to 2 years
Length of Initial Hospitalization
Time frame: Implant to the end of the initial hospitalization
Number of Participants Who Had a Re-hospitalization
Time frame: Implant to two years
Duration of Re-hospitalization
Time frame: Implant to two years
Cause of Re-hospitalization
Time frame: Implant to two years
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Sep 2018.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Results publication: PubMed 28146651Rogers JG, Pagani FD, Tatooles AJ, Bhat G, Slaughter MS, Birks EJ, Boyce SW, Najjar SS, Jeevanandam V, Anderson AS, Gregoric ID, Mallidi H, Leadley K, Aaronson KD, Frazier OH, Milano CA. Intrapericardial Left Ventricular Assist Device for Advanced Heart Failure. N Engl J Med. 2017 Feb 2;376(5):451-460. doi: 10.1056/NEJMoa1602954.
- Derived from this study: PubMed 32740343Mahr C, McGee E Jr, Cheung A, Mokadam NA, Strueber M, Slaughter MS, Danter MR, Levy WC, Cheng RK, Beckman JA, May DM, Ismyrloglou E, Tsintzos SI, Silvestry SC. Cost-Effectiveness of Thoracotomy Approach for the Implantation of a Centrifugal Left Ventricular Assist Device. ASAIO J. 2020 Aug;66(8):855-861. doi: 10.1097/MAT.0000000000001209.
- Derived from this study: PubMed 32740129Silvestry SC, Mahr C, Slaughter MS, Levy WC, Cheng RK, May DM, Ismyrloglou E, Tsintzos SI, Tuttle E, Cook K, Birk E, Gomes A, Graham S, Cotts WG. Cost-Effectiveness of a Small Intrapericardial Centrifugal Left Ventricular Assist Device. ASAIO J. 2020 Aug;66(8):862-870. doi: 10.1097/MAT.0000000000001211.
- Intrapericardial Left Ventricular Assist Device for Advanced Heart FailureLink provided by the sponsor.
Related trials for Chronic Heart Failure
Not yet recruiting
RELIEVE-HFrEF TRIAL: REducing Lung congestIon Symptoms Using the v-wavE Shunt in adVancEd Heart Failure With Reduced EF
Heart Failure and Reduced Ejection Fraction, Heart Failure Chronic
Not yet recruiting
Community Health Worker Nutrition Self-Management Support for Cardio-Kidney-Metabolic Health
Hypertension (HTN), CKD - Chronic Kidney Disease
RecruitingPhase 4
The Effects of Low-Dose Versus High-Dose Intravenous IRON Therapy With Ferric DerisomaltOSE in Patients With Chronic Heart Failure and Iron Deficiency
Heart Failure, Iron Deficiency
Recruiting
WIN Ratio Analysis to Determine a Strategy of Non- Invasive SUpport for Respiratory Failure in the EmeRgency Department
Acute Hypoxic Respiratory Failure, Acute Respiratory Distress Syndrome (ARDS)
RecruitingObservational study
Norepinephrine in the Management of General Anesthesia-Induced Arterial Hypotension in Chronic Heart Failure Patients
Hypotension
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Francis Pagani, MD principal investigator
University of Michigan Hospital
Joseph Rogers, MD principal investigator
Duke University
48 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing HeartWare® VAS in people with Chronic Heart Failure, run by Medtronic Cardiac Rhythm and Heart Failure at 48 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 8 inclusion and 28 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 6 Sep 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 48 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 28 Feb 2018). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Stroke-Free Survival Probability for 2 Years Post Implant (time frame: Implant to 2 years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01166347, which also lists 3 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Sep 2018.