BleedingNCT01090843
Video Capsule Endoscopy (VCE) Comparison Study
A study testing Video capsule endoscopy (VCE), MiroCam and Enteropro EndoCapsule in people with Bleeding and Anemia, run by Medical University of Vienna at 1 site in Austria.
Trial summary
MiroCam® is the new video capsule endoscope of IntroMedic®. By using a novel transmission technology it promises a longer battery life expectancy with consequential impact on the length of the video recorded for diagnostic evaluation. Read more about this study
- Who is it for?
- Ages 18 to 85 years
- What is being tested?
- Video capsule endoscopy (VCE), MiroCam and Enteropro EndoCapsule
- Type of treatment
- Pill or oral medicine, Medical device, Surgery or procedure
- How many people
- 50 participants
- Where
- 1 siteAustria
- Study dates
- Apr 2010to Oct 2011
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients transferred to our unit to undergo video capsule endoscopy because of
- Obscure digestive bleeding (ODB)
- Chronic anaemia of unknown origin
- Chronic diarrhoea
Who cannot join
- Patients age below 18 years
- Patients presenting with contraindications to video capsule endoscopy which are already known gastrointestinal stenoses, already known gastrointestinal adhesions, already known diverticula of the small bowel, already known severe or diabetes induced intestinal hypomotility
- Refusal to participate in the study
Trial locations and contacts
1 site in 1 country.
Austria1 site
Medical University of Vienna, Department of Medicine III., Clinical Division of Gastroenterology and Hepatology
Vienna, A-1090
About this study
Official title: Comparison Study of IntroMedic®'s MiroCam® and Olympus®' Enteropro EndoCapsule®
MiroCam® is the new video capsule endoscope of IntroMedic®. By using a novel transmission technology it promises a longer battery life expectancy with consequential impact on the length of the video recorded for diagnostic evaluation. As the investigators know about the shortcoming of battery life expectancy from many capsule examinations that were inconclusive because the ileocaecal transit was not filmed, the investigators would appreciate to have a capsule with extended video recording to improve the diagnostic yield of capsule examinations. Therefore the investigators want to compare MiroCam® to our routinely used Olympus® Enteropro EndoCapsule® in the context of a half-year clinical trial. Focussing on the total video length as well as on the rate of video-recorded ileocaecal transitions as surrogate parameters the investigators want to find out whether one of the two products provides superior diagnostic information in order to reduce the amount of inconclusive examinations.
Read the detailed description
Introduction
Video capsule endoscopy (VCE) is an important tool in the diagnostic management of several gastrointestinal (GI) disorders. Taking a video while passing the GI tract, VCE is the only technique providing image information of the whole small bowel. It is a comfortable and safe procedure; complications due to capsule retention are rare [1]. The main disadvantage of VCE is made up by its only dependence on macroscopic information. Therefore it can not be reliably used for the detection of disorders that need histological confirmation. However, lots of macroscopic pathologies can be diagnosed or excluded by VCE. Above all, obscure digestive bleeding (ODB) has become the main indication for the use of VCE [2].
Independent from the type of bowel preparation used, the ileocaecal transit cannot be visualized in up to 20 percent of VCE examinations, which means the loss of diagnostic information of the last intestinal parts [3]. Risk factors of such incomplete VCE include previous small-bowel surgery, hospitalization, moderate or poor bowel cleansing and a gastric transit time longer than 45 minutes [4]. Especially in the latter case, the success of the examination is determined by the battery life expectancy of the capsule technology used [5].
The new MiroCam®, a brand of IntroMedic®, is advertised to have a longer battery life expectancy than competitive products throughout the market. To prove this pronouncement, a pilot-study of 16 patients was presented by He Man Kim at the UEGW 2008, comparing MiroCam® to Given®'s PillCam® by sequential application of both capsules. Although the battery life expectancy of MiroCam® was significantly higher, there was no significant difference in the diagnostic yield of both products [6]. Currently a similar comparison study between MiroCam® and Pill Cam® is ongoing in France, involving a higher amount of patients [unpublished data].
Study Aims
In this prospective study we want to compare IntroMedic®'s MiroCam® to Olympus® Enteropro EndoCapsule® which was so far routinely used at our department. We want to investigate whether one of the two products provides superior diagnostic information about the small bowel. The primary endpoint will be the total video length registered as well as the rate of successful ileocoecal transitions during ongoing video registration. The secondary end point will be the number of pathologies detected by each capsule. If there will be a significant difference between the two tested products, preferred usage of the superior product may improve the diagnostic yield of future examinations by avoiding incomplete video registration of the small bowel.
Study Design
Prospective Study without randomisation or blinding
Study Population
Patients transferred to our unit to undergo video capsule endoscopy because of
- Obscure digestive bleeding (ODB)
- Chronic anaemia of unknown origin
- Chronic diarrhoea
Exclusion criteria:
- Patients age below 18 years
- Patients presenting with contraindications to video capsule endoscopy which are already known gastrointestinal stenoses, already known gastrointestinal adhesions, already known diverticula of the small bowel, already known severe or diabetes induced intestinal hypomotility
- Refusal to participate in the study
Methods
Our investigation will be performed at the Medical University of Vienna, department of medicine III, clinical division of gastroenterology and hepatology. Patient recruitment will start on the 1st of January 2010. The study will last for six month. The number of patients included within this period will be around 50, based on the current amount of VCE examinations performed at our department.
All patients who fulfil the listed inclusion criteria, will receive the patient information form of this study together with the routine informed consent form of VCE. Potentially occurring questions about the course of the examination, data acquisition and processing in context of the study will be answered by medical professionals.
As routine preparation for VCE, patients will receive 2 litres of washout solution on the previous day of their examination. At the day of the procedure fasting is required. The patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later - to our knowledge the first capsule will have already passed the gastro-duodenal transit at this time. The two capsules used in our investigation are the already mentioned MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list. After both capsules have been swallowed, fasting has to be continued for four hours to prevent image interference of VCE.
Risk/Benefit Assessment
The safety of both products used within our investigation was already proved in former clinical trials [7, 8]. For the patients enrolled in our study the potentially higher risk of complications will be made up for the expected increase of diagnostic yield that will be implicated by the evaluation of two different bowel videos. The only notable discomfort for patients participating in our investigation will be caused by the rather high amount of adhesive electrodes necessary for both capsules. There should not be any interference of the two video signals as already shown in former investigations [6,9].
- Being tested
- Video capsule endoscopy (VCE), MiroCam, Enteropro EndoCapsule
- Keywords
- Obscure digestive bleeding (ODB), Chronic anaemia of unknown origin, Chronic diarrhoea
- Medical subject headings
- Hemorrhage, Anemia, Diarrhea
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Video capsule endoscopy (VCE)Procedure or surgery
In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list.
MiroCamDevice
In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list.
Enteropro EndoCapsuleDevice
In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list.
What is being measured
The primary outcome is the main question the study is designed to answer.
Total video length
The primary endpoint will be the total video length registered as well as the rate of successful ileocoecal transitions during ongoing video registration.
Measured: 6 months
Secondary outcomes (1)
Diagnostic yield
The secondary end point will be the number of pathologies detected by each capsule.
Measured: 6 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Mar 2010 (estimated)
- Study startApr 2010
- Primary completionApr 2011
- Study completionOct 2011
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (9)Papers the sponsor has linked to this study.
- Other trials for BleedingStudies of the same condition, open and under way.
- More trials run by Medical University of ViennaThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 50 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medical University of Vienna
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Werner Dolak, MD, Medical University of Vienna
- Investigators
- Andreas Puespoek, MD, Study director, Medical University of ViennaWerner Dolak, MD, Principal investigator, Medical University of Vienna
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT01090843
- Sponsor's protocol ID
- EK 961/2009
- Status last verified
- Oct 2011
- First submitted
- 22 Mar 2010
- Last updated
- 5 Oct 2011
- Results posted
- No
- Data monitoring committee
- No
Publications
Munoz-Navas M. Capsule endoscopy. World J Gastroenterol. 2009 Apr 7;15(13):1584-6. doi: 10.3748/wjg.15.1584.
PubMed 19340899Nakamura T, Terano A. Capsule endoscopy: past, present, and future. J Gastroenterol. 2008;43(2):93-9. doi: 10.1007/s00535-007-2153-6. Epub 2008 Feb 29.
PubMed 18306982Kalantzis C, Triantafyllou K, Papadopoulos AA, Alexandrakis G, Rokkas T, Kalantzis N, Ladas SD. Effect of three bowel preparations on video-capsule endoscopy gastric and small-bowel transit time and completeness of the examination. Scand J Gastroenterol. 2007 Sep;42(9):1120-6. doi: 10.1080/00365520701251601.
PubMed 17710680Westerhof J, Weersma RK, Koornstra JJ. Risk factors for incomplete small-bowel capsule endoscopy. Gastrointest Endosc. 2009 Jan;69(1):74-80. doi: 10.1016/j.gie.2008.04.034. Epub 2008 Aug 8.
PubMed 18691709Sanchez-Yague A. Risk factors for incomplete small-bowel capsule endoscopy: should capsule retention be considered independently? Gastrointest Endosc. 2009 Oct;70(4):820; author reply 820. doi: 10.1016/j.gie.2009.02.018. No abstract available.
PubMed 19788996He Man Kim. Sequential capsule endoscopy of two different capsule endoscopes, MiroCam and Pillcam SB1, without interference: a pilot study. UEGW Oct 21, 2008.
Bang S, Park JY, Jeong S, Kim YH, Shim HB, Kim TS, Lee DH, Song SY. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation. Gastrointest Endosc. 2009 Feb;69(2):253-9. doi: 10.1016/j.gie.2008.04.033. Epub 2008 Jul 21.
PubMed 18640676Gheorghe C, Iacob R, Bancila I. Olympus capsule endoscopy for small bowel examination. J Gastrointestin Liver Dis. 2007 Sep;16(3):309-13.
PubMed 17925927Cave DR, Fleischer DE, Leighton JA, Faigel DO, Heigh RI, Sharma VK, Gostout CJ, Rajan E, Mergener K, Foley A, Lee M, Bhattacharya K. A multicenter randomized comparison of the Endocapsule and the Pillcam SB. Gastrointest Endosc. 2008 Sep;68(3):487-94. doi: 10.1016/j.gie.2007.12.037. Epub 2008 Apr 14.
PubMed 18410941
Study at a glance
From the registry record, last updated by the sponsor on 5 Oct 2011. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparison Study of IntroMedic®'s MiroCam® and Olympus®' Enteropro EndoCapsule®
- ClinicalTrials.gov ID
- NCT01090843
- Acronym / sponsor ID
- EK 961/2009
- Keywords
- Obscure digestive bleeding (ODB), Chronic anaemia of unknown origin, Chronic diarrhoea
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 50 participants (actual)
- Lead sponsor
- Medical University of ViennaUniversity, hospital or other
- Study start
- Apr 2010
- Primary completion
- Apr 2011 (actual)
- Study completion
- Oct 2011 (actual)
- First posted
- 23 Mar 2010 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
MiroCam® is the new video capsule endoscope of IntroMedic®. By using a novel transmission technology it promises a longer battery life expectancy with consequential impact on the length of the video recorded for diagnostic evaluation. As the investigators know about the shortcoming of battery life expectancy from many capsule examinations that were inconclusive because the ileocaecal transit was not filmed, the investigators would appreciate to have a capsule with extended video recording to improve the diagnostic yield of capsule examinations. Therefore the investigators want to compare MiroCam® to our routinely used Olympus® Enteropro EndoCapsule® in the context of a half-year clinical trial. Focussing on the total video length as well as on the rate of video-recorded ileocaecal transitions as surrogate parameters the investigators want to find out whether one of the two products provides superior diagnostic information in order to reduce the amount of inconclusive examinations.
Detailed description
Introduction
Video capsule endoscopy (VCE) is an important tool in the diagnostic management of several gastrointestinal (GI) disorders. Taking a video while passing the GI tract, VCE is the only technique providing image information of the whole small bowel. It is a comfortable and safe procedure; complications due to capsule retention are rare [1]. The main disadvantage of VCE is made up by its only dependence on macroscopic information. Therefore it can not be reliably used for the detection of disorders that need histological confirmation. However, lots of macroscopic pathologies can be diagnosed or excluded by VCE. Above all, obscure digestive bleeding (ODB) has become the main indication for the use of VCE [2].
Independent from the type of bowel preparation used, the ileocaecal transit cannot be visualized in up to 20 percent of VCE examinations, which means the loss of diagnostic information of the last intestinal parts [3]. Risk factors of such incomplete VCE include previous small-bowel surgery, hospitalization, moderate or poor bowel cleansing and a gastric transit time longer than 45 minutes [4]. Especially in the latter case, the success of the examination is determined by the battery life expectancy of the capsule technology used [5].
The new MiroCam®, a brand of IntroMedic®, is advertised to have a longer battery life expectancy than competitive products throughout the market. To prove this pronouncement, a pilot-study of 16 patients was presented by He Man Kim at the UEGW 2008, comparing MiroCam® to Given®'s PillCam® by sequential application of both capsules. Although the battery life expectancy of MiroCam® was significantly higher, there was no significant difference in the diagnostic yield of both products [6]. Currently a similar comparison study between MiroCam® and Pill Cam® is ongoing in France, involving a higher amount of patients [unpublished data].
Study Aims
In this prospective study we want to compare IntroMedic®'s MiroCam® to Olympus® Enteropro EndoCapsule® which was so far routinely used at our department. We want to investigate whether one of the two products provides superior diagnostic information about the small bowel. The primary endpoint will be the total video length registered as well as the rate of successful ileocoecal transitions during ongoing video registration. The secondary end point will be the number of pathologies detected by each capsule. If there will be a significant difference between the two tested products, preferred usage of the superior product may improve the diagnostic yield of future examinations by avoiding incomplete video registration of the small bowel.
Study Design
Prospective Study without randomisation or blinding
Study Population
Patients transferred to our unit to undergo video capsule endoscopy because of
- Obscure digestive bleeding (ODB)
- Chronic anaemia of unknown origin
- Chronic diarrhoea
Exclusion criteria:
- Patients age below 18 years
- Patients presenting with contraindications to video capsule endoscopy which are already known gastrointestinal stenoses, already known gastrointestinal adhesions, already known diverticula of the small bowel, already known severe or diabetes induced intestinal hypomotility
- Refusal to participate in the study
Methods
Our investigation will be performed at the Medical University of Vienna, department of medicine III, clinical division of gastroenterology and hepatology. Patient recruitment will start on the 1st of January 2010. The study will last for six month. The number of patients included within this period will be around 50, based on the current amount of VCE examinations performed at our department.
All patients who fulfil the listed inclusion criteria, will receive the patient information form of this study together with the routine informed consent form of VCE. Potentially occurring questions about the course of the examination, data acquisition and processing in context of the study will be answered by medical professionals.
As routine preparation for VCE, patients will receive 2 litres of washout solution on the previous day of their examination. At the day of the procedure fasting is required. The patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later - to our knowledge the first capsule will have already passed the gastro-duodenal transit at this time. The two capsules used in our investigation are the already mentioned MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list. After both capsules have been swallowed, fasting has to be continued for four hours to prevent image interference of VCE.
Risk/Benefit Assessment
The safety of both products used within our investigation was already proved in former clinical trials [7, 8]. For the patients enrolled in our study the potentially higher risk of complications will be made up for the expected increase of diagnostic yield that will be implicated by the evaluation of two different bowel videos. The only notable discomfort for patients participating in our investigation will be caused by the rather high amount of adhesive electrodes necessary for both capsules. There should not be any interference of the two video signals as already shown in former investigations [6,9].
Study design
- Primary purpose
- Diagnosis
- Allocation
- Randomised
- Intervention model
- Single group
- Masking
- Single blind (outcomes assessor)
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Patients transferred to our unit to undergo video capsule endoscopy because of
- Obscure digestive bleeding (ODB)
- Chronic anaemia of unknown origin
- Chronic diarrhoea
Key exclusion criteria (3 listed)
- Patients age below 18 years
- Patients presenting with contraindications to video capsule endoscopy which are already known gastrointestinal stenoses, already known gastrointestinal adhesions, already known diverticula of the small bowel, already known severe or diabetes induced intestinal hypomotility
- Refusal to participate in the study
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Video capsule endoscopy (VCE)In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list. | Procedure or surgery | – |
| MiroCamIn the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list. | Device | – |
| Enteropro EndoCapsuleIn the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list. | Device | – |
Primary outcome
Total video length
Time frame: 6 months
The primary endpoint will be the total video length registered as well as the rate of successful ileocoecal transitions during ongoing video registration.
1 secondary outcome
Diagnostic yield
Time frame: 6 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 5 Oct 2011.
- Background: PubMed 19340899Munoz-Navas M. Capsule endoscopy. World J Gastroenterol. 2009 Apr 7;15(13):1584-6. doi: 10.3748/wjg.15.1584.
- Background: PubMed 18306982Nakamura T, Terano A. Capsule endoscopy: past, present, and future. J Gastroenterol. 2008;43(2):93-9. doi: 10.1007/s00535-007-2153-6. Epub 2008 Feb 29.
- Background: PubMed 17710680Kalantzis C, Triantafyllou K, Papadopoulos AA, Alexandrakis G, Rokkas T, Kalantzis N, Ladas SD. Effect of three bowel preparations on video-capsule endoscopy gastric and small-bowel transit time and completeness of the examination. Scand J Gastroenterol. 2007 Sep;42(9):1120-6. doi: 10.1080/00365520701251601.
- Background: PubMed 18691709Westerhof J, Weersma RK, Koornstra JJ. Risk factors for incomplete small-bowel capsule endoscopy. Gastrointest Endosc. 2009 Jan;69(1):74-80. doi: 10.1016/j.gie.2008.04.034. Epub 2008 Aug 8.
- Background: PubMed 19788996Sanchez-Yague A. Risk factors for incomplete small-bowel capsule endoscopy: should capsule retention be considered independently? Gastrointest Endosc. 2009 Oct;70(4):820; author reply 820. doi: 10.1016/j.gie.2009.02.018. No abstract available.
- BackgroundHe Man Kim. Sequential capsule endoscopy of two different capsule endoscopes, MiroCam and Pillcam SB1, without interference: a pilot study. UEGW Oct 21, 2008.
- Background: PubMed 18640676Bang S, Park JY, Jeong S, Kim YH, Shim HB, Kim TS, Lee DH, Song SY. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation. Gastrointest Endosc. 2009 Feb;69(2):253-9. doi: 10.1016/j.gie.2008.04.033. Epub 2008 Jul 21.
- Background: PubMed 17925927Gheorghe C, Iacob R, Bancila I. Olympus capsule endoscopy for small bowel examination. J Gastrointestin Liver Dis. 2007 Sep;16(3):309-13.
- Background: PubMed 18410941Cave DR, Fleischer DE, Leighton JA, Faigel DO, Heigh RI, Sharma VK, Gostout CJ, Rajan E, Mergener K, Foley A, Lee M, Bhattacharya K. A multicenter randomized comparison of the Endocapsule and the Pillcam SB. Gastrointest Endosc. 2008 Sep;68(3):487-94. doi: 10.1016/j.gie.2007.12.037. Epub 2008 Apr 14.
Related trials for Bleeding
Recruiting
Contribution of GFAP and UCH-L1 Assays in Whole Blood to Optimizing Personalized Care for "Repeated Fallers" Hospitalized in Geriatric Wards
Fallers Aged 60 Years and Older, Biomarkers / Blood
RecruitingObservational study
Development and Validation of Risk Prediction Models for Stroke and Cognitive Impairment in Moyamoya Disease and Moyamoya Syndrome
Moyamoya Disease, Moyamoya Syndrome
Enrolling by invitationEarly Phase 1
Clinical Safety and Efficacy Evaluation of the Blood-cooling and Stasis-removing Formula as an Adjunct to Atorvastatin in the Treatment of Hemorrhagic Moyamoya Disease.
Moyamoya Disease
RecruitingPhase 2
HMBeacon: A Phase 2 Study to Evaluate ALN-6400 in Adult and Adolescent Female Patients With VWD and HMB
Von Willebrand Disease (VWD), Heavy Menstrual Bleeding (HMB)
Not yet recruitingPhase 3
Extended Post-Operative Oral Tranexamic Acid Dosing After ACL Reconstruction
Anterior Cruciate Ligament Injuries, Anterior Cruciate Ligament Rupture
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Andreas Puespoek, MD study director
Medical University of Vienna
Werner Dolak, MD principal investigator
Medical University of Vienna
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Video capsule endoscopy (VCE), MiroCam and Enteropro EndoCapsule in people with Bleeding and Anemia, run by Medical University of Vienna at 1 site in Austria.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 5 Oct 2011. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Austria. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Total video length (time frame: 6 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT01090843, which also lists 9 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?