AzTrials
AzTrials

Carotid Artery StenosisPhase 3EMBOLDENNCT00766493

GORE® Embolic Filter in Carotid Stenting for High Risk Surgical Subjects (EMBOLDEN)

A Phase 3 study testing GORE® Embolic Filter in people with Carotid Artery Stenosis, run by W.L.Gore & Associates.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Compare the 30-day safety and efficacy of the GORE® Embolic Filter used in conjunction with FDA-approved carotid stents to a performance goal obtained from carotid stent studies utilizing distal embolic protection. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Carotid Artery Stenosis
What is being tested?
GORE® Embolic Filter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
250 participants
Where
No sites listed yet
Study dates
Jan 2009to Jul 2010
Phase
Phase 3
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Subject is either:
  • Symptomatic (amaurosis fugax in the hemisphere supplied by the target vessel, TIA or non-disabling stroke within 6 months of the procedure) with carotid stenosis ≥50% as diagnosed by angiography using NASCET methodology, OR
  • Asymptomatic with carotid stenosis ≥80% as diagnosed by angiography using NASCET methodology
  • Target lesion is located in one of the following:
  • ICA
  • bifurcation
  • CCA proximal to the bifurcation
  • At Anatomic risk for adverse events from CEA (e.g., restenosis after a prior CEA) or at Co-morbid risk for adverse events from CEA (e.g., unstable angina with ECG changes)

Who cannot join

  • Recent surgical procedure within 30 days before or after the stent procedure
  • Uncontrolled sensitivity to contrast media
  • Renal Insufficiency
  • Recent evolving, acute stroke within 21 days of study evaluation
  • Myocardial infarction within 72 hours prior to stent procedure
  • History of a prior major ipsilateral stroke with residual neurological deficits likely to confound the neurological assessments (e.g., NIHSS)
Show all 16Show fewer
  • Neurological deficits not due to stroke likely to confound the neurological assessments (e.g., NIHSS)
  • Angiographic Exclusion Criteria:
  • Isolated ipsilateral hemisphere leading to subject intolerance to reverse flow
  • Total occlusion of the ipsilateral carotid artery
  • Pre-existing stent in the ipsilateral carotid artery OR the contralateral carotid artery that extends into the aortic arch
  • Presence of a filling defect, thrombus, occlusion or "string sign" in the target vessel
  • Severe lesion calcification restricting stent deployment
  • Carotid stenosis located distal to target stenosis that is more severe than target stenosis
  • >50% stenosis of the CCA proximal to target vessel
  • Known mobile plaque in the aortic arch

About this study

Official title: GORE® Embolic Filter in Carotid Stenting for High Risk Surgical Subjects (GORE EMBOLDEN)

Compare the 30-day safety and efficacy of the GORE® Embolic Filter used in conjunction with FDA-approved carotid stents to a performance goal obtained from carotid stent studies utilizing distal embolic protection.

Read the detailed description

Continuous advances in angioplasty techniques and the development of low-profile, flexible, tapered nitinol stents designed specifically for carotid applications have made CAS a viable alternative to CEA. Advances in embolic protection technology will assist in moving CAS forward as a universally accepted procedure. While the GORE® Embolic Filter is similar in many ways to other currently available filters, it has been designed to provide optimal vessel wall apposition. Bench tests suggest that the wall apposition may provide improved filter efficiency, thereby minimizing embolization of particles downstream and potentially decreasing adverse clinical effects. In addition, preclinical testing suggests that the GORE® Embolic Filter has improved deliverability, including torque ability and lesion cross that may improve the ability of the system to access and treat tight lesions in tortuous anatomy. Thus, the purpose of this multi-center clinical study is to assess the safety and effectiveness of the GORE® Embolic Filter when used to provide cerebral embolic protection during carotid artery angioplasty and stenting.

Being tested
GORE® Embolic Filter
Keywords
carotid artery stenosis, embolic protection device, distal embolic filter, minimizing risks of carotid artery stenting
Medical subject headings
Carotid Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • GORE® Embolic FilterDevice

    Embolic protection during carotid stenting

Study groups in NCT00766493
Study groupRoleWhat they receive
GORE® Embolic FilterExperimentalSubjects treated with the GORE® Embolic Filter and an FDA-approved carotid stent.
Receives: Device: GORE® Embolic Filter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Composite Major Adverse Event (MAE) Rate of Death, Myocardial Infarction, and Stroke at 30 Days Postprocedure

    Measured: 30 days

Secondary outcomes (4)
  1. Device Success

    Device Success defined as the number of participants with Technical Success using the GORE Embolic Protection System (i.e., the GORE Embolic Filter device was delivered, placed, and retrieved as outlined in the Instructions for Use).

    Measured: Post Procedure

  2. Clinical Success

    Clinical Success defined as GORE Embolic Filter and carotid stent success in the absence of death, emergency endarterectomy, repeat PTA / thrombolysis of the target vessel, and stroke or MI as determined by the Clinical Events Committee. Clinical success will be evaluated from procedure through 24-48 hours postprocedure.

    Measured: 30 days

  3. Access Site Complications

    Access Site Complications defined as the presence of a large hematoma (>5cm or requiring treatment or prolonged hospitalization), fistula or pseudoaneurysm formation, retroperitoneal bleeding or the need for surgical repair postprocedure.

    Measured: 30 days

  4. Neurologic Events

    Neurological Events at 30 days post-procedure, including transient ischemic attacks (TIAs).

    Measured: 30 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Oct 2008 (estimated)
  2. Study startJan 2009
  3. Primary completionJul 2010
  4. Study completionJul 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 3
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
250 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00766493
Sponsor's protocol ID
GEF-06-08
Acronym
EMBOLDEN
Status last verified
Aug 2016
First submitted
3 Oct 2008
Last updated
29 Sep 2016
Data monitoring committee
Yes

Questions about this trial

What is this clinical trial studying?

A Phase 3 study testing GORE® Embolic Filter in people with Carotid Artery Stenosis, run by W.L.Gore & Associates.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 8 inclusion and 16 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 Sep 2016. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 3 studies compare the treatment with the current standard treatment or a placebo in a large group, to confirm how well it works and watch for side effects.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Yes. Results are posted in the registry (first posted 7 Aug 2012). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Composite Major Adverse Event (MAE) Rate of Death, Myocardial Infarction, and Stroke at 30 Days Postprocedure (time frame: 30 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Sep 2016.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in