The APPROPRIATE study will compare differences in functional capacity (peak VO2) between chronotropically incompetent patients randomized to receive rate responsive pacing driven by either the minute ventilation (respiration-based) sensor or an accelerometer (motion-based). Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Heart Diseases
What is being tested?
Rate adaptive pacemaker
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
566 participants
Where
2 sitesUnited States
Study dates
Dec 2008to Jan 2011
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Meets or met current pacemaker implantation indications
  • Willing and capable of providing informed consent for participation
  • Receiving a dual-chamber pacemaker or previously received a dual-chamber pacemaker with active atrial and ventricular leads
  • Plans to remain in the long-term care of his/her enrolling physician and is available for study follow-up for three months post-enrollment

Who cannot join

  • Mobitz II second degree heart block
  • Third degree heart block
  • Chronic atrial fibrillation or uncontrolled atrial arrhythmias within the past 90 days prior to consent
  • Neuromuscular, orthopedic, or vascular disability that prevents normal walking or weight carrying (e.g., intermittent claudication, arthritis, residual stroke weakness, need for a wheelchair or walker)
  • A symptom-limited exercise protocol is thought to be dangerous or contra-indicated, including but not limited to changing pattern of chest discomfort or uncontrolled arrhythmias
  • Pulmonary disease as defined by any one of the following:
Show all 16Show fewer
  • Forced Vital Capacity (FVC) or Forced Expiratory Volume in one second (FEV1) < 60% of predicted values
  • Use of two or more pulmonary inhalers
  • Use of supplemental oxygen
  • Chronic use of oral steroids for pulmonary disease treatment
  • Life expectancy is less than 12 months due to other medical conditions, per physician discretion
  • Has or indicated for an implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy-defibrillator (CRT-D)
  • Currently enrolled in another investigational study that would directly impact the treatment or outcome of the current study.
  • Younger than 18 years of age
  • Pregnant or planning to become pregnant during the study (method of assessment upon physician's discretion)
  • Unable or unwilling to comply with the protocol requirements

Trial locations and contacts

2 sites in 1 country.

United States2 sites
  • Genesis Heart Institute

    Davenport, Iowa

  • Cardiology Association of NE Arkansas

    Jonesboro, Arkansas

Other trials in United States

About this study

Official title: Assessment of Proper Physiologic Response With Rate Adaptive Pacing Driven by Minute Ventilation or Accelerometer

The APPROPRIATE study will compare differences in functional capacity (peak VO2) between chronotropically incompetent patients randomized to receive rate responsive pacing driven by either the minute ventilation (respiration-based) sensor or an accelerometer (motion-based).

Conditions
Heart Diseases
Being tested
Rate adaptive pacemaker
Keywords
Pacemaker
Medical subject headings
Heart Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Rate adaptive pacemakerDevice

    Accelerometer sensor

  • Rate adaptive pacemakerDevice

    Minute ventilation sensor

Study groups in NCT00757666
Study groupRoleWhat they receive
AccelerometerActive comparatorPatients implanted with a Boston Scientific ALTRUA 60 pacemaker with accelerometer (motion-based) sensor.
Receives: Device: Rate adaptive pacemaker
Minute VentilationActive comparatorPatients implanted with a Boston Scientific ALTRUA 60 pacemaker with minute ventilation sensor.
Receives: Device: Rate adaptive pacemaker

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mean Change in Functional Capacity (Peak VO2).

    The APPROPRIATE Study compared differences in functional capacity (peak VO2) between CI patients randomized to receive rate responsive pacing driven by either the minute ventilation (respiration-based) sensor or by an accelerometer (motion-based) sensor.

    The mean change in functional capactity will be compared against baseline; changes from baseline will be measured.

    Measured: 1 month and 2 months post-implant

Secondary outcomes (4)
  1. Changes in Heart Rate During Activities of Daily Living (ADL) Using a Lift and Carry Test

    This outcome measure will be compared against baseline.

    Measured: 2 months post-implant

  2. Metabolic Chronotropic Relationship (MCR) Slope

    Measured: 1 month and 2 months post-implant

  3. Exercise Time

    Measured: 1 month and 2 months post-implant

  4. VO2 at Ventilatory Threshold

    Measured: 1 month and 2 months post-implant

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Sep 2008 (estimated)
  2. Study startDec 2008
  3. Primary completionJan 2011
  4. Study completionJan 2011

Why it stopped: Difficulty enrollment; higher than planned patient attrition and data attrition

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
566 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00757666
Sponsor's protocol ID
CR-CA-082808-B
Acronym
APPROPRIATE
Status last verified
May 2017
First submitted
19 Sep 2008
Last updated
14 Jun 2017
Data monitoring committee
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Rate adaptive pacemaker in people with Heart Diseases, run by Boston Scientific Corporation at 2 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 16 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 14 Jun 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 14 Jun 2017). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Mean Change in Functional Capacity (Peak VO2). (time frame: 1 month and 2 months post-implant). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jun 2017.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
APPROPRIATE - Rate Adaptive Pacing Sensor | AzTrials