Coronary Artery DiseaseAGILITYNCT00686647
AngioSculpt® Coronary Bifurcation Study
A study testing AngioSculpt® Scoring Balloon Catheter and AngioSculpt Scoring Balloon Catheter in people with Coronary Artery Disease and Myocardial Ischemia, run by AngioScore, Inc. at 1 site in United States.
Trial summary
The purpose of this study is to evaluate a new angioplasty catheter, AngioSculpt® for the treatment of bifurcation lesions (blockages occurring at branch points) in coronary arteries. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease, Myocardial Ischemia
- What is being tested?
- AngioSculpt® Scoring Balloon Catheter and AngioSculpt Scoring Balloon Catheter
- Type of treatment
- Medical device
- How many people
- 93 participants
- Where
- 1 siteUnited States
- Study dates
- Apr 2008to Jan 2011
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- At least 18 years of age and able to give informed consent.
- Patients with significant (> 50% diameter stenosis) native coronary artery disease involving a bifurcation and the ostium of the side branch vessel (Medina class (x, x, 1)) including stable or unstable angina and silent ischemia.
- Patients with lesions suitable for percutaneous coronary intervention (PCI).
Who cannot join
- Concomitant use of Rotablator, Cutting Balloon, or investigational coronary devices.
- Additional planned coronary interventions for a non-target lesion within 9 months of the study procedure.
- Left ventricular ejection fraction < 35%
- Patients refusing or not candidates for emergency coronary artery bypass grafting (CABG)surgery
- Uncontrolled severe hypertension (systolic BP >180 mm Hg or diastolic BP >110 mm Hg)
- Patients who are not candidates for chronic treatment with aspirin or Clopidogrel/Ticlopidine
Show all 27Show fewer
- Severe renal failure with creatinine >2.0 mg/dL
- Untreated pre-procedural hemoglobin <10 g/dL
- Coagulopathy manifested by platelet count <100,000 or International Normalized ratio (INR) >2.0 (INR is only required in patients who have taken warfarin within 2 weeks of enrollment)
- Women who are known or suspected to be pregnant
- Patients in cardiogenic shock
- Acute myocardial infarction (MI) within the past 72 hours, and/or elevated CPK (and abnormal Troponin-I) at the time of enrollment
- Patients with a life expectancy of less than 1 year
- Target main branch vessel < 2.5 mm in diameter
- Target main branch lesion > 30 mm in length
- Intended use of a bare metal stent (BMS) in the main branch
- Target side branch vessel < 2.0 mm in diameter
- Target side branch lesion > 15 mm in length
- Target bifurcation angle > 90º (distal angle)
- Totally obstructed target coronary arteries (TIMI 0 or 1 flow)
- Target bifurcation lesion within a previously placed stent (i.e. in-stent restenosis (ISR))
- Target bifurcation lesion within a surgical conduit (e.g. saphenous vein or internal mammary)
- Target lesion demonstrating severe dissection prior to planned deployment of the AngioSculpt device
- Unprotected Left Main diameter stenosis ≥ 50%
- Visible thrombus (by angiography) at target lesion site
- Coronary spasm in the absence of a significant stenosis
- Patients who are concurrently participating in an investigational study when such participation could confound the treatment or outcomes of this study
Trial locations and contacts
1 site in 1 country.
United States1 site
Columbia University Medical Center
New York, New York, 10032
About this study
Official title: AngioSculpt® Scoring Balloon Catheter Multi-Center Coronary Bifurcation Study
The purpose of this study is to evaluate a new angioplasty catheter, AngioSculpt® for the treatment of bifurcation lesions (blockages occurring at branch points) in coronary arteries.
Read the detailed description
Background: Bifurcation lesions, which consist of a narrowing occurring at branch points of coronary arteries, typically involve both the main branch (parent vessel) and an adjacent side branch. These lesions pose a particularly challenging situation for angioplasty procedures due to the difficulty of covering both branches with stents and a higher rate of recurrence (restenosis). A new angioplasty scoring balloon catheter (AngioSculpt®) has recently been approved for the treatment of narrowings in coronary arteries. The AngioSculpt® catheter incorporates a nitinol device that consists of spiral wires that wrap around the balloon catheter. As the balloon inflates, the spiral wires score the lesion allowing the balloon to be more stable (avoid slippage) and may enlarge the narrowed sections of the artery with less pressure or risk of dissection (uncontrolled tearing of the inner lining of the artery wall commonly seen with conventional balloons).
Study Purpose: To demonstrate the safety and efficacy of the AngioSculpt® used in conjunction with coronary stents (implantable wire mesh tubes for scaffolding blocked arteries) for the treatment of coronary artery bifurcation narrowings and to compare these results with the historical outcomes associated with the use of conventional balloons and stents in the treatment of bifurcation lesions.
Study Design: A prospective, multi-center, non-randomized, single-arm study with results compared to a literature search derived historical control for conventional balloon angioplasty (OPC - Objective Performance Criteria). The intent of this study is to enroll and treat 100 patients at 8 U.S. interventional cardiology programs with clinical follow-up planned at 30 days and 9 months following the procedure.
- Conditions
- Coronary Artery Disease, Myocardial Ischemia
- Being tested
- AngioSculpt® Scoring Balloon Catheter, AngioSculpt Scoring Balloon Catheter
- Keywords
- Coronary Angioplasty, Coronary Stents, Scoring Balloons, Coronary Artery Bifurcation Lesions
- Medical subject headings
- Coronary Artery Disease, Myocardial Ischemia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
AngioSculpt® Scoring Balloon CatheterDevice
Use of a stent for the main branch of a bifurcation lesion and use of a scoring balloon for the side branch of the same bifurcation lesion
AngioSculpt Scoring Balloon CatheterDevice
Treatment of the side-branch vessel of true bifurcation lesions using the AngioSculpt device
What is being measured
The primary outcome is the main question the study is designed to answer.
Procedural Success
Defined as less than or equal to 30% diameter stenosis in the main branch and less than or equal to 70% diameter stenosis in the side branch at the conclusion of the procedure (including adjunctive stenting) in the absence of in-hospital major adverse cardiac events (MACE) [cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR]
Measured: 1 day
Secondary outcomes (2)
Major Adverse Cardiovascular Events
cardiac death, myocardial infarction, or target lesion revascularization
Measured: 30 days
Major Adverse Cardiac Events
cardiac death, myocardial infarction, or target lesion revascularization
Measured: 9 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted30 May 2008 (estimated)
- Study startApr 2008
- Primary completionApr 2010
- Study completionJan 2011
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 93 participants (actual)
Sponsor and investigators
- Lead sponsor
- AngioScore, Inc.
- Sponsor type
- Industry (pharma, biotech, devices)
- Investigators
- Jeffrey W. Moses, M.D., Principal investigator, Columbia University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT00686647
- Sponsor's protocol ID
- ASC-ST1210
- Acronym
- AGILITY
- Status last verified
- Jul 2011
- First submitted
- 28 May 2008
- Last updated
- 10 Aug 2011
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
Publications
Weisz G, Metzger DC, Liberman HA, O'Shaughnessy CD, Douglas JS Jr, Turco MA, Mehran R, Gershony G, Leon MB, Moses JW. A provisional strategy for treating true bifurcation lesions employing a scoring balloon for the side branch: final results of the AGILITY trial. Catheter Cardiovasc Interv. 2013 Sep 1;82(3):352-9. doi: 10.1002/ccd.24630. Epub 2013 Mar 9.
PubMed 22927100
Study at a glance
From the registry record, last updated by the sponsor on 10 Aug 2011. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- AngioSculpt® Scoring Balloon Catheter Multi-Center Coronary Bifurcation Study
- ClinicalTrials.gov ID
- NCT00686647
- Acronym / sponsor ID
- AGILITY / ASC-ST1210
- Conditions
- Coronary Artery Disease, Myocardial Ischemia
- Keywords
- Coronary Angioplasty, Coronary Stents, Scoring Balloons, Coronary Artery Bifurcation Lesions
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 93 participants (actual)
- Lead sponsor
- AngioScore, Inc.Industry (pharma, biotech, devices)
- Study start
- Apr 2008
- Primary completion
- Apr 2010 (actual)
- Study completion
- Jan 2011 (actual)
- First posted
- 30 May 2008 (estimated)
- Results
- Posted 10 Aug 2011
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to evaluate a new angioplasty catheter, AngioSculpt® for the treatment of bifurcation lesions (blockages occurring at branch points) in coronary arteries.
Detailed description
Background: Bifurcation lesions, which consist of a narrowing occurring at branch points of coronary arteries, typically involve both the main branch (parent vessel) and an adjacent side branch. These lesions pose a particularly challenging situation for angioplasty procedures due to the difficulty of covering both branches with stents and a higher rate of recurrence (restenosis). A new angioplasty scoring balloon catheter (AngioSculpt®) has recently been approved for the treatment of narrowings in coronary arteries. The AngioSculpt® catheter incorporates a nitinol device that consists of spiral wires that wrap around the balloon catheter. As the balloon inflates, the spiral wires score the lesion allowing the balloon to be more stable (avoid slippage) and may enlarge the narrowed sections of the artery with less pressure or risk of dissection (uncontrolled tearing of the inner lining of the artery wall commonly seen with conventional balloons).
Study Purpose: To demonstrate the safety and efficacy of the AngioSculpt® used in conjunction with coronary stents (implantable wire mesh tubes for scaffolding blocked arteries) for the treatment of coronary artery bifurcation narrowings and to compare these results with the historical outcomes associated with the use of conventional balloons and stents in the treatment of bifurcation lesions.
Study Design: A prospective, multi-center, non-randomized, single-arm study with results compared to a literature search derived historical control for conventional balloon angioplasty (OPC - Objective Performance Criteria). The intent of this study is to enroll and treat 100 patients at 8 U.S. interventional cardiology programs with clinical follow-up planned at 30 days and 9 months following the procedure.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- At least 18 years of age and able to give informed consent.
- Patients with significant (> 50% diameter stenosis) native coronary artery disease involving a bifurcation and the ostium of the side branch vessel (Medina class (x, x, 1)) including stable or unstable angina and silent ischemia.
- Patients with lesions suitable for percutaneous coronary intervention (PCI).
Key exclusion criteria (27 listed)
- Concomitant use of Rotablator, Cutting Balloon, or investigational coronary devices.
- Additional planned coronary interventions for a non-target lesion within 9 months of the study procedure.
- Left ventricular ejection fraction < 35%
- Patients refusing or not candidates for emergency coronary artery bypass grafting (CABG)surgery
- Uncontrolled severe hypertension (systolic BP >180 mm Hg or diastolic BP >110 mm Hg)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| AngioSculpt® Scoring Balloon CatheterUse of a stent for the main branch of a bifurcation lesion and use of a scoring balloon for the side branch of the same bifurcation lesion | Device | – |
| AngioSculpt Scoring Balloon CatheterTreatment of the side-branch vessel of true bifurcation lesions using the AngioSculpt device | Device | – |
Primary outcome
Procedural Success
Time frame: 1 day
Defined as less than or equal to 30% diameter stenosis in the main branch and less than or equal to 70% diameter stenosis in the side branch at the conclusion of the procedure (including adjunctive stenting) in the absence of in-hospital major adverse cardiac events (MACE) [cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR]
2 secondary outcomes
Major Adverse Cardiovascular Events
Time frame: 30 days
Major Adverse Cardiac Events
Time frame: 9 months
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 10 Aug 2011.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Derived from this study: PubMed 22927100Weisz G, Metzger DC, Liberman HA, O'Shaughnessy CD, Douglas JS Jr, Turco MA, Mehran R, Gershony G, Leon MB, Moses JW. A provisional strategy for treating true bifurcation lesions employing a scoring balloon for the side branch: final results of the AGILITY trial. Catheter Cardiovasc Interv. 2013 Sep 1;82(3):352-9. doi: 10.1002/ccd.24630. Epub 2013 Mar 9.
Related trials for Coronary Artery Disease
Not yet recruitingPhase 1/2
EDIT-401 in Adults Who Require Additional Lowering of Low-Density Lipoprotein Cholesterol (LDL-C)
Heterozygous Familial Hypercholesterolemia (HeFH)
Active, not recruitingPhase 3
Coronary Computed Tomography Study to Assess the Effect of Inclisiran in Addition to Maximally Tolerated Statin Therapy on Atherosclerotic Plaque Progression in Participants With a Diagnosis of Non-obstructive Coronary Artery Disease Without Previous Cardiovascular Events
Coronary Artery Disease
RecruitingObservational study
Characterization of Patients With Uncommon Presentations and/or Uncommon Diseases Associated With the Cardiovascular System
Metabolic Disease, Obesity
Active, not recruiting
Troponin in Acute Chest Pain to Risk Stratify and Guide EffecTive Use of Computed Tomography Coronary Angiography
Coronary Artery Disease
Recruiting
A Prospective, Multicenter, Randomized Controlled Trial to Investigate the Value of Coronary CT Angiography in the Understanding and Management of Coronary Calcium (The Optimal Trial)
Cardiovascular Diseases, Myocardial Ischemia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jeffrey W. Moses, M.D. principal investigator
Columbia University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing AngioSculpt® Scoring Balloon Catheter and AngioSculpt Scoring Balloon Catheter in people with Coronary Artery Disease and Myocardial Ischemia, run by AngioScore, Inc. at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 27 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 10 Aug 2011. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 10 Aug 2011). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Procedural Success (time frame: 1 day). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT00686647, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Aug 2011.