Coronary Artery DiseasePhase 2/3MARTINNCT00637104

European Multicenter, Randomized, Comparative Efficacy/Safety Study of the Mar-Tyn TiN-Coated Stent

A Phase 2/3 study testing Mar-Tyn TiN coated Co-Cr Numen stent implant and Vision Co-Cr stent implant in people with Coronary Artery Disease and Angioplasty, Transluminal, Percutaneous Coronary, run by International Biomedical Systems S.p.A. at 7 sites in 4 countries.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The main objective of this study is to assess the safety and effectiveness of the TiN-coated MAR-Tyn stent in maintaining minimum lumen diameter in de novo native coronary artery lesions as compared to an uncoated control cobalt-chromium balloon-expandable stent (Vision, Abbott Vascular). Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Mar-Tyn TiN coated Co-Cr Numen stent implant and Vision Co-Cr stent implant
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
160 participants
Where
7 sitesin 4 countries
Study dates
Jul 2008to Jun 2011
Phase
Phase 2/3
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients must meet ALL of the following criteria:
  • The patient must be > 18 years of age;
  • Female of childbearing potential must have a negative pregnancy test within 7 days of enrollment and utilize reliable birth control for eight months after enrollment
  • Diagnosis of angina pectoris as defined by Canadian Cardiovascular Society Classification (CCS I, II, III, IV) OR unstable angina pectoris (Braunwald Classification B\&C, I-II) OR patients with documented silent ischemia;
  • Single treatment of de novo lesion in a major coronary artery in patients with single or multi-vessel disease; patients with multiple lesions can be included only if the other lesions do not require treatment;
  • Target vessel diameter at the lesion site is >2.50mm and <3.5mm in diameter (visual estimate);
Show all 13Show fewer
  • Target lesion is >10mm and <22mm in length (visual estimate);
  • Target lesion stenosis is >50% and <100% (visual estimate);
  • At least TIMI II coronary flow;
  • Acceptable candidate for coronary artery bypass surgery (CABG);
  • Patient is willing to comply with the specified follow-up evaluation;
  • Patient must provide written informed consent prior to the procedure using a form that is approved by the local Ethics Committee.
  • Patient can be pre-treated with aspirin and clopidogrel or, alternatively, aspirin alone plus a loading dose of 300 mg of clopidogrel before procedure completion in case of urgent PCI

Who cannot join

  • Patients will be excluded if ANY of the following conditions apply:
  • Patient has experienced a Q-wave or non-Q-wave myocardial infarction with documented total CK >2 times normal within the preceding 24 hours and the CK and CK-MB enzymes remains above normal at the time of treatment;
  • Has unstable angina classified as Braunwald III B or C and A I-II-III, or is having a peri infarction;
  • Unprotected left main coronary disease with >50% stenosis;
  • Significant (>50%) stenosis proximal or distal to the target lesion that might require revascularization or impede runoff;
  • Have an ostial target lesion;
Show all 25Show fewer
  • Have a target lesion in a venous graft;
  • Angiographic evidence of thrombus within target lesion;
  • Calcified lesion which cannot be successfully predilated;
  • Documented left ventricular ejection fraction <=25%;
  • Totally occluded vessel (TIMI 0 level);
  • Impaired renal function (creatinine > 3.0 mg/dl) at the time of treatment;
  • Pretreatment with devices other than balloon angioplasty;
  • Target lesion has excessive tortuousity or angulation (> 45°) which makes it unsuitable for stent delivery and deployment;
  • Target lesion involves bifurcation including a diseased side branch >=2 mm in diameter (either stenosis of both main vessel and major branch or stenosis of just major branch) that would require side branch stenting;
  • Prior stent within 5mm of target lesion;
  • Direct Stenting
  • Recipient of heart transplant;
  • Patient with a life expectancy less than 12 months;
  • Known allergies to the following: aspirin, clopidogrel bisulfate (Plavix) and ticlopidine (Ticlid), heparin, cobalt, chromium, or contrast agent (that cannot be managed medically)
  • Recent (6 months) cerebrovascular accidents or intracranial hemorrhage
  • Any significant medical condition which in the investigator's opinion may interfere with the patient's optimal participation in the study;
  • Currently participating in an investigational drug or another device study;
  • Intervention of another lesion has occurred within 6 months before the index procedure;
  • In the investigator's opinion, the lesion is not suitable for stenting.

Trial locations and contacts

7 sites in 4 countries.

Luigi Marras, Dr. MEng. PhD. contact

+39 3346738578

luigi.marras@ibsmed.it

Nader Shehata, Dr. Eng. contact

+39 040 3755 639

Nader.shehta@ibsmed.it

7 sites in 4 countries

Italy4 sites, 4 recruiting
  • Policlinico Universitario di Bari-Emodinamica Interventista

    Bari, BA

    Bortone, abortone@cardiochir.uniba.it

    Alessandro Bortone, Dr. MD

    Recruiting
  • Ospedale San Raffaele- Emodinamica e Cardiologia

    Milan, MI

    Antonio Colombo, Dr. MD, colombo.antonio@hsr.it

    Antonio Colombo, Dr. MD

    Recruiting
  • Ospedale di Ravenna, U.O. Cardiologia

    Ravenna, Ra

    Marco Balducelli, Dr. MD, +39 0544 285 388, ra.hocardioemo@ausl.ra.it

    Marco Balducelli, Dr. MD

    Recruiting
  • Campus Biomedico, Cardiologia

    Roma, Roma

    Germano Di Sciascio, Dr. MD, +39 06225411, g.disciascio@unicampus.it

    Germano Di Sciascio, Dr. MD

    Recruiting

Other trials in Italy

Germany1 site, 1 recruiting
  • Department of Internal Medicine III (Cardiology), University of Freiburg im Breisgau

    Freiburg im Breisgau, 79106

    Christoph Hehrlein, Prof. MD, hehrlein@Medizin.Ukl.Uni-Freiburg.De

    Christoph Hehrlein, Prof. MD

    Recruiting

Other trials in Germany

Netherlands1 site, 1 recruiting
  • CARIM, Department of Cardiology

    Maastricht

    J. Waltenberger, Prof. MD, j.waltenberger@cardio.azm.nl

    J. Waltenberger, Prof. MD

    Recruiting

Other trials in Netherlands

Switzerland1 site, 1 recruiting
  • Cardiocentro Ticino, Cardiologia

    Lugano

    Tiziano Moccetti, tiziano.moccetti@cardiocentro.org

    Tiziano Moccetti, Prof. MD

    Recruiting

Other trials in Switzerland

About this study

Official title: A European Multicenter, Randomized, Single Blind Study of the MAR-Tyn Cobalt Chromium TiN-Coated Balloon-Expandable Stent in the Treatment of Patients With de Novo Coronary Artery Lesions

The main objective of this study is to assess the safety and effectiveness of the TiN-coated MAR-Tyn stent in maintaining minimum lumen diameter in de novo native coronary artery lesions as compared to an uncoated control cobalt-chromium balloon-expandable stent (Vision, Abbott Vascular). Both stents are mounted on a Rapid Exchange Stent Delivery System.

Read the detailed description

Occlusive coronary artery disease is predominantly caused by coronary atherosclerosis, a pathologic vascular condition characterized by abnormal lipid and fibrous tissue accumulation in the vessel wall. This condition may be accompanied by degenerative changes and/or calcification leading to stenosis (narrowing) of the luminal channel. Percutaneous Transluminal Coronary Angioplasty (PTCA) is a well-accepted method of non-surgical myocardial revascularization for selected patients with symptomatic occlusive coronary artery disease.

Restenosis is the most important challenge limiting the long-term success of coronary angioplasty. Symptomatic restenosis usually occurs 6 months after an angioplasty procedure. The rates of restenosis reported in numerous clinical trials vary from 13% to 57%. This variability may be attributed in part to differences in the methods used to assess the occurrence of restenosis and in the criteria used to define restenosis. Regardless of the exact percentage, restenosis remains the Achilles heel of angioplasty. Numerous pharmaceutical approaches to limit restenosis have been tested, but none have been successful to date.

It was chosen to coat the stent with Titanium Nitrate (TiN), which is an inert, biocompatible material, that creates a thin physical barrier to diffusion of toxic metal atoms, TiN creates a very smooth surface that is impossible to obtain with a metal alloy. This coating was applied to the cobalt chromium platform, "Numen", made of the L605 Cobalt-20 Chromium-15 Tungsten-10 Nickel alloy. This alloy contains the lowest Nickel percentage of Cobalt Chromium alloys used for surgical implants. The strut thickness of the platform is reduced to the minimum of 65 microns for optimal hemodynamic performance and to permit an ultra low profile delivery system. The "Numen" design complies with the requirements of the "LMS -Less Mismatch Stent" theory applied where multiple 1 mm high zigzags form the stent pattern to align the segments at 45° with respect to blood flow when the stent is expanded to its nominal diameter. TiN coating is being used commercially for their hard-wearing and chemical inactive properties, particularly for surgical tools. TiN features chemical stability, great hardness, excellent wear properties, low electric impedance, biocompatibility, hemocompatibility and the possibility, through the application process, to exchange the orientation of the grains, the hardness, the wear characteristics and also the biocompatibility (a nanocrystalline structure produces a chemical surface more suitable for the endothelial cells). The produced coatings were very fine grained and dense with a porosity within the film structure of less than 10 nm in diameter. Furthermore, in an iliac artery stent model in normal rabbits, safety and efficacy in reduced restenosis of the TiN coated Numen™ stent was assessed.

The special TiN coating of the Mar-Tyn stents is very promising in reducing the lesions and the causes of intima neoplasia.

This study is a multicenter (up to 8 European centers), prospective, randomized single blind study. This study has a 2-arm design assessing the safety and effectiveness of the Tin-coated MAR-Tyn stent to an uncoated control cobalt-chromium balloon-expandable stent (Vision, Abbott Vascular), both mounted on a Rapid Exchange Stent Delivery System. A total of 160 patients will be entered in the study and will be randomized on a 1:1 basis. Patients who meet the eligibility criteria will be either randomized to Treatment A or Treatment B. The patient will not know which stent will be implanted while the physician will be unblinded . Patients will be followed at 30 days, 6, and 12 months post-procedure, with all patients undergoing repeat angiography at 6 months. All adverse events up to the 1 year follow-up period will be collected and analyzed.

Being tested
Mar-Tyn TiN coated Co-Cr Numen stent implant, Vision Co-Cr stent implant
Keywords
percutaneous transluminal coronary angioplasty, stents, restenosis, biocompatible materials, ceramics
Medical subject headings
Coronary Artery Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Mar-Tyn TiN coated Co-Cr Numen stent implantDevice

    Also called Mar-Tyn, martin, TiN coated stent

    Implant of the Mar-tyn TiN coated stent

  • Vision Co-Cr stent implantDevice

    Also called cobalt-chromium stent

    Implant of the Vision stent

Study groups in NCT00637104
Study groupRoleWhat they receive
A - Mar-tynExperimentalIt includes the implant of the Mar-tyn TiN coated stent
Receives: Device: Mar-Tyn TiN coated Co-Cr Numen stent implant
B - VisionActive comparatorIncludes all the patients treated with the Vision stent
Receives: Device: Vision Co-Cr stent implant

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. in-stent minimum lumen diameter (MLD)

    Measured: 6 months

Secondary outcomes (4)
  1. Composite of Major Adverse Cardiac Events (MACE) defined as death, myocardial infarction (Q wave and non-Q wave), emergent bypass surgery, thrombosis, or repeat target lesion revascularization

    Measured: 30 days, 6 months, 12 months

  2. Angiographic binary restenosis (>50% diameter stenosis) 6 months post-procedure. In-lesion minimum lumen diameter (MLD) at 6 months post-procedure.

    Measured: 6 months

  3. Target lesion revascularization (TLR) at 6 months post-procedure. Target vessel revascularization (TVR) at 6 months post-procedure.

    Measured: 6 months

  4. • Device success defined as achievement of a final residual diameter stenosis of <30% (by QCA), using the assigned device only. If QCA is not available, the visual estimate of diameter stenosis is used.

    Measured: 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted17 Mar 2008 (estimated)
  2. Study startJul 2008
  3. Primary completionDec 2010 (estimated)
  4. Study completionJun 2011 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 2/3
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
160 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00637104
Sponsor's protocol ID
IBS/03-2007
Acronym
MARTIN
Status last verified
Feb 2010
First submitted
10 Mar 2008
Last updated
9 Feb 2010
Results posted
No
Data monitoring committee
Yes

Questions about this trial

What is this clinical trial studying?

A Phase 2/3 study testing Mar-Tyn TiN coated Co-Cr Numen stent implant and Vision Co-Cr stent implant in people with Coronary Artery Disease and Angioplasty, Transluminal, Percutaneous Coronary, run by International Biomedical Systems S.p.A. at 7 sites in 4 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 13 inclusion and 25 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 9 Feb 2010. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 7 sites in Italy, Germany, Netherlands, Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this combined phase mean?

Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.

Phase 3 studies compare the treatment with the current standard treatment or a placebo in a large group, to confirm how well it works and watch for side effects.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Luigi Marras, Dr. MEng. PhD. (+39 3346738578, luigi.marras@ibsmed.it), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

in-stent minimum lumen diameter (MLD) (time frame: 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Feb 2010.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in