AzTrials
AzTrials

Coronary Artery DiseaseBRANCHNCT00607321

Bare Metal Bifurcation Stent Clinical Trial in Humans

A study testing Medtronic Bifurcation Stent System in people with Coronary Artery Disease and Myocardial Ischemia, run by Medtronic Vascular at 1 site in New Zealand.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To assess the feasibility and safety of the Medtronic Bifurcation Stent System for the treatment of single de novo bifurcation lesions in native coronary arteries with reference vessel diameters (RVD) for the proximal main vessel of 3.8 - 4.3 mm, distal main branch of 3.0 - 3.5 mm, and side branch RVD up to 2.5 mm. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Coronary Artery Disease, Myocardial Ischemia
What is being tested?
Medtronic Bifurcation Stent System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteNew Zealand
Study dates
Feb 2008to Aug 2010
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

General Inclusion Criteria

  • Candidate for percutaneous coronary intervention \& emergent coronary artery bypass graft surgery
  • Clinical evidence of ischemic heart disease or a positive functional study
  • Female patients of childbearing potential has negative pregnancy test within 7 days before trial procedure
  • Patient or patient's legal representative provided written informed consent
  • Patient agrees to comply with follow-up evaluations

Angiographic Inclusion Criteria

  • Target lesion ia a single de novo bifurcation lesion involving a native coronary artery with reference vessel diameter for the proximal main of 3.8 - 4.3 mm, distal main of 3.0 - 3.5 mm, \& side branch RVD up to 2.5 mm
  • Acceptable target lesion lengths are any combination of:
  • <16mm proximally from carina in proximal main vessel
  • <16mm distally from the carina in distal main branch
  • <12mm from carina in side branch
  • Target lesion in main vessel has stenosis of > 50% and <100%
  • Target vessel has (TIMI) flow >2

General Exclusion Criteria

  • Known hypersensitivity/contraindication to aspirin, heparin or bivalirudin, clopidogrel or ticlopidine, cobalt, nickel, chromium, molybdenum, or sensitivity to contrast media, which can't be adequately pre-medicated
  • Platelet count <100,000 cells/mm³ or >700,000 cells/mm³, or a white blood cell (WBC) count <3,000 cells/mm³ within 7 days prior to index procedure
  • Serum creatinine level >170 micromol/L within 7 days prior to index procedure
  • Evidence of acute MI within 72 hours of intended trial procedure (defined as: QWMI or NQWMI having CK enzymes >2X laboratory upper limit of normal with presence of elevated CK-MB (any amount above laboratory upper limit of normal)
  • Previous stenting anywhere in target vessel
  • PCI of non-target vessel within 30 days prior to procedure that results in any MACE event. If non target vessel stent is implanted within 72 hours prior to index procedure, 2 post procedural serial CK or CK-MB measurements must be below investigational site's upper limit of normal.
  • PCI of non-target vessel within 24 hours prior to procedure
  • Planned PCI of any vessel within 30 days post-procedure
  • Planned PCI of the target vessel within 6 months post-procedure
  • During index procedure, target lesion requires treatment with device other than PTCA or cutting balloon prior to stent placement
  • Documented left ventricular ejection fraction (LVEF) <30% at most recent evaluation.
  • History of stroke or transient ischemic attack (TIA) within prior 6 months
  • Active peptic ulcer or upper gastrointestinal (GI) bleeding within prior 6 months
  • History of bleeding diathesis or coagulopathy or will refuse blood transfusions
  • Concurrent medical condition with life expectancy < 12 months
  • Currently participating in investigational drug or device trial that's not completed the primary endpoint or that clinically interferes with current trial endpoints; or requires coronary angiography, IVUS or other coronary artery imaging procedures.

Angiographic Exclusion Criteria

  • Bifurcation angle of >90 degrees by visual estimate
  • Target lesion located in native vessel with saphenous vein graft or left/right internal mammary artery (LIMA/RIMA) bypass
  • Significant stenosis (>50%) proximal or distal to target lesion that might require revascularization or impede run off.
  • Target vessel is excessively tortuous (two bends >90º to reach target lesion)
  • Target lesion has any of following characteristics:
  • Lesion location is aorto-ostial, unprotected left main lesion, or within 5 mm of origin of left anterior descending (LAD), left circumflex (LCX), or right coronary artery (RCA).
  • Severely calcified
  • Evidence of thrombus
  • Co-existence of unprotected left main coronary artery disease (obstruction >50% in left main coronary artery)

Trial locations and contacts

1 site in 1 country.

New Zealand1 site
  • Auckland City Hospital

    Auckland

Other trials in New Zealand

About this study

Official title: The Medtronic Bare Metal Bifurcation Stent Clinical Trial in Humans

To assess the feasibility and safety of the Medtronic Bifurcation Stent System for the treatment of single de novo bifurcation lesions in native coronary arteries with reference vessel diameters (RVD) for the proximal main vessel of 3.8 - 4.3 mm, distal main branch of 3.0 - 3.5 mm, and side branch RVD up to 2.5 mm.

Being tested
Medtronic Bifurcation Stent System
Keywords
restenosis, Coronary Disease, Coronary Arteriosclerosis, Arterial Occlusive Diseases
Medical subject headings
Coronary Artery Disease, Myocardial Ischemia, Coronary Disease, Arterial Occlusive Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Medtronic Bifurcation Stent SystemDevice

    Percutaneous Coronary Stenting

Study groups in NCT00607321
Study groupRoleWhat they receive
1ExperimentalMedtronic Bifurcation Stent System
Receives: Device: Medtronic Bifurcation Stent System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Participants With Target Vessel Failure (TVF) at 30 Days Post Procedure.

    TVF was reported if any of the following events occurred: Recurrent MI in territory not clearly attributed to a vessel other than the target lesion; Cardiac death not clearly due to a non-target vessel endpoint or Clinically driven target revascularization.

    Measured: 30 days

Secondary outcomes (4)
  1. Device Success

    Device success is reported as Historical-standard definition: attainment of <50% residual stenosis of all target lesion/s using only the assigned device and any adjunct stents as specified in the Investigational Plan.

    Measured: During index procedure

  2. Number of Participants With Target Vessel Failure (TVF) at 6 Months

    TVF was reported if any of the following events occurred: Recurrent MI in territory not clearly attributed to a vessel other than the target lesion; Cardiac death not clearly due to a non-target vessel endpoint or Clinically driven target revascularization.

    Measured: 6 month

  3. Number of Participants With Target Vessel Failure at 9 Months.

    TVF was reported if any of the following events occurred: Recurrent MI in territory not clearly attributed to a vessel other than the target lesion; Cardiac death not clearly due to a non-target vessel endpoint or Clinically driven target revascularization.

    Measured: 9 month

  4. Number of Participant With Target Vessel Failure at 12 Months

    TVF was reported if any of the following events occurred: Recurrent MI in territory not clearly attributed to a vessel other than the target lesion; Cardiac death not clearly due to a non-target vessel endpoint or Clinically driven target revascularization.

    Measured: 12 month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Feb 2008 (estimated)
  2. Study startFeb 2008
  3. Primary completionAug 2010
  4. Study completionAug 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00607321
Sponsor's protocol ID
IP088
Acronym
BRANCH
Status last verified
Apr 2017
First submitted
22 Jan 2008
Last updated
18 May 2017
Data monitoring committee
Yes

Publications

  • Sakata K, Koo BK, Waseda K, Nakatani D, Yock PG, Whitbourn R, Worthley SG, Ormiston J, Webster M, Wilkins GT, Honda Y, Meredith IT, Fitzgerald PJ. A Y-shaped bifurcation-dedicated stent for the treatment of de novo coronary bifurcation lesions: an IVUS analysis from the BRANCH trial. EuroIntervention. 2015 Mar 22;10(11):e1-8. doi: 10.4244/EIJY14M08_16.

    PubMed 25169593

Questions about this trial

What is this clinical trial studying?

A study testing Medtronic Bifurcation Stent System in people with Coronary Artery Disease and Myocardial Ischemia, run by Medtronic Vascular at 1 site in New Zealand.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 18 May 2017. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in New Zealand. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 31 Aug 2011). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Participants With Target Vessel Failure (TVF) at 30 Days Post Procedure. (time frame: 30 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00607321, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 18 May 2017.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in