AzTrials
AzTrials

AtherosclerosisSTRIDESNCT00475566

A Safety and Efficacy Study of the Dynalink®-E Everolimus Eluting Peripheral Stent System

A study testing Dynalink®-E everolimus-eluting peripheral stent and Dynalink®-E, everolimus-eluting peripheral stent in people with Atherosclerosis and Peripheral Vascular Disease, run by Abbott Medical Devices at 10 sites in 4 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this first-in-man study is to evaluate the safety and performance of the Dynalink®-E everolimus eluting peripheral stent system for the treatment of patients with atherosclerotic de novo or restenotic native superficial femoral and proximal popliteal lesions. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Atherosclerosis, Peripheral Vascular Disease
What is being tested?
Dynalink®-E everolimus-eluting peripheral stent and Dynalink®-E, everolimus-eluting peripheral stent
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
104 participants
Where
10 sitesin 4 countries
Study dates
May 2007to Feb 2010
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Rutherford Becker Category 2-5
  • Single de novo or restenotic lesion in the superficial femoral or proximal popliteal artery
  • Disease segment length 30-170 mm
  • >50% diameter stenosis or total occlusion
  • Target reference vessel diameter 4.3-7.3 mm

Who cannot join

  • Target lesion previously treated with stent or surgery
  • Rutherford Becker Category 0, 1, or 6
  • Immunosuppressive disorder or currently receiving immunosuppressive agents
  • Serum creatinine >2.5 mg/dl

Trial locations and contacts

10 sites in 4 countries.

10 sites in 4 countries

Germany4 sites
  • Herzzentrum Bad Krozingen

    Bad Krozingen, 79189

  • The Jewish Hospital Berlin

    Berlin, 13347

  • Herzzentrum Leipzig

    Leipzig, 04289

  • University Hospital Tübingen

    Tübingen, 72076

Other trials in Germany

Belgium3 sites
  • Sint Blasius Hospital

    Dendermonde

  • ZOL St. Jan

    Ghent, 3600

  • University Hospital

    Ghent, 9000

Other trials in Belgium

Austria2 sites
  • Landeskrankenhaus Klagenfurt

    Klagenfurt, 9020

  • Allgemeines Krankenhaus der Stadt Wien- AKH Wien

    Vienna, 1090

Other trials in Austria

Italy1 site
  • Casa di Cura di Montevergine

    Mercogliano, 83013

Other trials in Italy

About this study

Official title: A Study to Evaluate the Safety and Performance of the Dynalink®-E, Everolimus Eluting Peripheral Stent System for Treating Atherosclerotic de Novo or Restenotic Native Superficial Femoral and Proximal Popliteal Artery Lesions

The purpose of this first-in-man study is to evaluate the safety and performance of the Dynalink®-E everolimus eluting peripheral stent system for the treatment of patients with atherosclerotic de novo or restenotic native superficial femoral and proximal popliteal lesions.

Abbott Vascular is ceasing data analysis of the STRIDES Clinical Trial after 2 years. The decision to discontinue the study is not related to any safety concern. The rationale for this proposal is based on the following considerations:

Read more

The performance of DYNALINK-E from STRIDES shows no device- or procedure-related deaths and no stent fractures, and the rate of additional revascularizations has been stable since approximately 14 months after the procedure.

Evaluations of the bare metal nitinol DYNALINK and ABSOLUTE stents in the clinical literature show low rates of death, reintervention and stent fracture, which are consistent with STRIDES and demonstrate the safety of the nitinol stent platform of the DYNALINK-E.

Long-term animal studies show no concerns with the drug or polymer coating of DYNALINK-E - everolimus tissue concentration drops below the quantifiable limit by approximately 17 months after implant, and vascular response to the coating is normal with widely patent lumens and struts incorporated into vessel tissue.

The safety and performance of the DYNALINK-E has been substantiated by its clinical and pre-clinical data, and by the clinical data of similar products. Given the demonstrated mechanical integrity of the stent along with the evidence of a healthy long-term vascular response, there is a reasonable expectation of continued low event rates.

Read the detailed description

A prospective, Non-Randomized, Single-arm, Multi-center, Clinical Study to Evaluate the Safety and Performance of the Dynalink®-E, Everolimus Eluting Peripheral Stent System for the Treatment of Atherosclerotic de Novo or Restenotic Native Superficial Femoral and Proximal Popliteal Artery Lesions.

Being tested
Dynalink®-E everolimus-eluting peripheral stent, Dynalink®-E, everolimus-eluting peripheral stent
Medical subject headings
Atherosclerosis, Peripheral Vascular Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Dynalink®-E everolimus-eluting peripheral stentDevice

    Stenting of atherosclerotic de novo or restenotic lesions (> 50% stenosis) in the native superficial femoral or proximal popliteal artery

  • Dynalink®-E, everolimus-eluting peripheral stentDevice

    Stenting of atherosclerotic de novo or restenotic lesions (> 50% stenosis) in the native superficial femoral or proximal popliteal artery

Study groups in NCT00475566
Study groupRoleWhat they receive
1OtherThis is a prospective, non-randomized, single-arm, multi-center study. A projected 100 patients will receive the stent(s) in this study at approximately 10-15 European sites. The primary objective is to evaluate the safety and performance of the Dynalink®-E everolimus eluting peripheral stent system for the treatment of patients with atherosclerotic de novo or restenotic native superficial femoral or proximal popliteal lesions.
Receives: Device: Dynalink®-E everolimus-eluting peripheral stent; Device: Dynalink®-E, everolimus-eluting peripheral stent

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. In-stent binary restenosis (>50% stenosis), as measured by duplex ultrasound

    Measured: 6 months

Secondary outcomes (3)
  1. Angiographic in-stent binary restenosis rate (>50%)

    Measured: 12 months

  2. Angiographic mean in-stent late loss, in-stent mean minimum lumen diameter (MLD), percent diameter stenosis

    Measured: 12 months

  3. Primary, and secondary patency

    Measured: 1, 6, 12, 18 months, 2, 3, 4, 5 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted21 May 2007 (estimated)
  2. Study startMay 2007
  3. Primary completionJul 2008
  4. Study completionFeb 2010

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Non-randomised
Intervention model
Single group
Masking
None (open label)
Enrolment
104 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT00475566
Sponsor's protocol ID
06-103
Acronym
STRIDES
Status last verified
Mar 2011
First submitted
16 May 2007
Last updated
10 Mar 2011
Results posted
No
Data monitoring committee
Yes

Publications

  • Lammer J, Scheinert D, Vermassen F, Koppensteiner R, Hausegger KA, Schroe H, Menon RM, Schwartz LB. Pharmacokinetic analysis after implantation of everolimus-eluting self-expanding stents in the peripheral vasculature. J Vasc Surg. 2012 Feb;55(2):400-5. doi: 10.1016/j.jvs.2011.08.048. Epub 2011 Nov 1.

    PubMed 22051872
  • Lammer J, Bosiers M, Zeller T, Schillinger M, Boone E, Zaugg MJ, Verta P, Peng L, Gao X, Schwartz LB. First clinical trial of nitinol self-expanding everolimus-eluting stent implantation for peripheral arterial occlusive disease. J Vasc Surg. 2011 Aug;54(2):394-401. doi: 10.1016/j.jvs.2011.01.047. Epub 2011 Jun 12.

    PubMed 21658885

Questions about this trial

What is this clinical trial studying?

A study testing Dynalink®-E everolimus-eluting peripheral stent and Dynalink®-E, everolimus-eluting peripheral stent in people with Atherosclerosis and Peripheral Vascular Disease, run by Abbott Medical Devices at 10 sites in 4 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 Mar 2011. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 10 sites in Germany, Belgium, Austria, Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

In-stent binary restenosis (>50% stenosis), as measured by duplex ultrasound (time frame: 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT00475566, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Mar 2011.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in