CataractPhase 4NCT00459303
Comparison of Functional Vision Provided by AMO Tecnis Z9000 and Alcon SA60AT Acrysof
A Phase 4 study testing aspherical intraocular lens and spherical intraocular lens in people with Cataract, run by National Taiwan University Hospital at 1 site in Taiwan.
Trial summary
This study is to compare intraindividually the functional vision provided by two different posterior chamber intraocular lenses: AMO Tecnis Z9000 and Alcon SA60AT Acrysoft. To see if the aspherical intraocular lenses provide better functional vision than traditional spherical intraocular lenses. Read more about this study
- Who is it for?
- Ages 45 to 80 yearsHealthy volunteers can take part
- Conditions the study is for
- Cataract
- What is being tested?
- aspherical intraocular lens and spherical intraocular lens
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 20 participants
- Where
- 1 siteTaiwan
- Study dates
- Oct 2005to Dec 2007
- Phase
- Phase 4
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 45 to 80 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Bilateral cataracts, eligible for phacoemulsification with primary implantation of a posterior chamber IOL
- Willing and able to comply with scheduled visits and other study procedures
Who cannot join
- Preoperative ocular pathology potentially affect visual acuity. EX: diabetic retinopathy, macular degeneration, corneal opacity, glaucoma, visual field defect...etc.
- Previous ocular surgery. Ex: refractive surgery, vitreoretinal surgery...etc.
- Patients who cannot cooperative with the study procedures
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Intraidivisual Comparison of Functional Vision Provided by AMO Tecnis Z9000 and ALcon SA60AT Acrysof Posterior Chamber Intraocular Lenses
This study is to compare intraindividually the functional vision provided by two different posterior chamber intraocular lenses: AMO Tecnis Z9000 and Alcon SA60AT Acrysoft. To see if the aspherical intraocular lenses provide better functional vision than traditional spherical intraocular lenses.
Read the detailed description
In this prospective study, 20 patients with bilateral catarct presenting for cataract surgery are randomly assigned to recieve an aspherical intraocular lens(AMO Tecnis Z9000) in one eye and a spherical intraocular lens(Alcon SA60AT Acrysof)in the other. All surgeries are performed by one experienced surgeon(Fung-Rong Hu,MD)with clear cornea small incision phacoemulsification and in-the-bag posterior chamber intraocular implantation.
The patients are followed for 3 months, and postoperative contrast sensitivity, contrast acuity, corneal \& total ocular high-ordered aberrations are measured and compared intraidividually between two different IOL groups.
Outcome Measurement:
- Contrast sensitivity testing: measured with spectacle correction for the target distance of three meters using wall-mounted FACT sine-wave grating chart with nine levels of contrast.The graphic contrast sensitivity is recorded as a log functional units on the y-axis and displayed for five spatial frequency targets (1.5, 3, 6, 12, 18 cycles per degree (cpd))on x- axis.
- Contrast acuity testing: measured with spectacle correction for the target distance of three meters using logMAR letter chart(Precision Vision®)represented on a wall-mounted illuminator cabinet.Two types of contrast charts are used, high contrast(Cat.No.2103 SLOAN translucent chart)and low contrast(Cat.No.2132 10% SLOAN translucent chart),and are tested under both photopic and mesopic conditions.
- Pupil diameters: measured by Colvard infrared pupillometer (Oasis. Medical, Glendora, CA, USA )under both photopic and mesopic luminance levels.
- Corneal aberration analysis: performed with TMS-4 (Tomey, Japan).The corneal HOAs are described with Zernike polynomials of 3rd-to 5th- order root-mean-square(RMS)of central 6mm diameter using VOLPro 6.89 software(Fa. Sarver and Associates, Carbondale. Ill, USA).
- Total ocular aberration analysis: performed with a Hartmann-Shack aberrometer(Zywave, Bausch \& Lomb Inc., Rochester, New. York)under maximal mydriasis with Mydrin-P(phenylephrine hydrochloride 0.5% and tropicamide 0.5%, Santen).The wavefront errors were described using Zernike polynomials RMS for total HOA at pupil diameter of 5 mm and 6 mm, primary spherical (Z 4,0) and 3rd-to 5th-order aberration at pupil diameter of 6 mm.
Data Analysis:
- Mann-Whitney U matched-paired test was used with STATA software
- P values of 0.05 or less were considered statistically significant
- Conditions
- Cataract
- Being tested
- aspherical intraocular lens, spherical intraocular lens
- Keywords
- cataract, aspherical intraocular lenses, functional vision
- Medical subject headings
- Cataract
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
aspherical intraocular lensDevice
Also called AMO Tecnis Z9000
implantation of aspherical intraocular lenses(AMO Tecnis Z9000)during cataract suregry (small cornea incision phacoemulsification, deliver with Monarch II device, in the bag implantation)
spherical intraocular lensDevice
Also called Alcon SA60AT Acrysof
implantation of spherical intraocular lenses(Alcon SA60AT Acrysof)during cataract suregry (small cornea incision phacoemulsification, deliver with Monarch II device, in the bag implantation)
| Study group | Role | What they receive |
|---|---|---|
| intraocular lens | Active comparator | patients with bilateral clinical significant cataract reisiceved cataract surgeries and recieved spherial intraocuar lens(SA60AT, Alcon) in one eye and aspherical intraocular lens(Tecnis Z9000, AMO)in the other respectively. Receives: Device: aspherical intraocular lens; Device: spherical intraocular lens |
What is being measured
The primary outcome is the main question the study is designed to answer.
Best Corrected logMAR Contrast Acuity at Photopic/Mesopic Condition
Contrast acuity testing was measured with spectacle correction for the target distance of three meters using a logMAR letter chart (Precision Vision®) represented on a wall-mounted illuminator cabinet. Two types of contrast charts were used, high contrast (Cat.No.2103 SLOAN translucent chart) and low contrast (Cat.No.2132 10% SLOAN translucent chart), and these were tested under both photopic (250 Lux) and mesopic (0.5 Lux) conditions. The contrast acuity tested ranges from 20/160 to 20/20(from worse to best), which equals LogMAR(Logarithm of the Minimum Angle of Resolution)0.9 to -0.3. All of the visual acuity and functional vision testing examinations mentioned above were performed by a single ophthalmologist. The outcomes were recorded as average of three post-operative measurments.
Measured: average data of post-op 3rd, 6th, 12th week measurements
Best Corrected Contrast Sensitivity in Photopic Condition
Contrast sensitivity testing was measured with spectacle correction for the target distance of three meters using a wall-mounted FACT sine-wave grating chart with nine levels of contrast (Stereo Optical Inc.)and five spatial frequency targets (1.5, 3, 6, 12, 18 cycles per degree (cpd)) at 250 lux. The last correct grating seen for each spatial frequency is recorded and translated by the "EYEVIEW™ Functional Analysis Software" into a log contrast sensitivity unit. The outcomes were recorded as average of the three post-operative measurements.
( physiological range of contrast sensitivity: 1.5 cpd : 25~82.5 ; 3 cpd: 30~150 ; 6 cpd: 65 ~ 200 ; 12 cpd: 20 ~130 ; 18 cpd: 6.5 ~ 65 )
Measured: average data of post-operative 3rd week, 6th week, 12th week measurements
Secondary outcomes (2)
Corneal High-order Aberrations
Corneal topography was performed with a TMS-4 corneal tomographer (Tomey, Japan). We used the 31-rings placido-based system that covers 10.9 mm of corneal diameter which is sufficient for the study of aberrations up to the fifth order for 6 mm diameter. Corneal HOAs were described with Zernike polynomials of 3rd- to 5th-order root-mean-square (RMS) of central 6mm diameter using VOLPro 6.89 software (Fa. Sarver and Associates, Carbondale. Ill, USA).
Measured: pre-op & averate data of post-op 3rd, 6th, 12th week measurements
Total Ocular High-order Aberrations
A Hartmann-Shack aberrometer (Zywave, Bausch \& Lomb Inc., Rochester, New York ) was used for measurement of HOAs of the whole eye. The measurements were done under maximal mydriasis with Mydrin-P (phenylephrine hydrochloride 0.5% and tropicamide 0.5%, Santen). The wavefront errors were described using the RMS of Zernike polynomials for total HOA at pupil diameters of 5 mm and 6 mm, primary spherical (Z 4,0) and 3rd-to 5th-order aberration at the pupil diameter of 6 mm.
Measured: average data of post-op 3rd, 6th, 12th week measurements
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Apr 2007 (estimated)
- Study startOct 2005
- Primary completionSep 2007
- Study completionDec 2007
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for CataractStudies of the same condition, open and under way.
- More trials run by National Taiwan University HospitalThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 4
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- Double blind
- Who is masked
- Participant, Outcomes assessor
- Enrolment
- 20 participants (actual)
Sponsor and investigators
- Lead sponsor
- National Taiwan University Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Pei-Yuang Su, MD, Principal investigator, National Taiwan Unoversity HospitalFung-Rong Hu, MD, Study chair, National Taiwan University Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT00459303
- Sponsor's protocol ID
- 05012006
- Status last verified
- Dec 2013
- First submitted
- 10 Apr 2007
- Last updated
- 17 Feb 2014
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 17 Feb 2014. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Intraidivisual Comparison of Functional Vision Provided by AMO Tecnis Z9000 and ALcon SA60AT Acrysof Posterior Chamber Intraocular Lenses
- ClinicalTrials.gov ID
- NCT00459303
- Acronym / sponsor ID
- 05012006
- Conditions
- Cataract
- Keywords
- cataract, aspherical intraocular lenses, functional vision
- Phase
- Phase 4
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 20 participants (actual)
- Lead sponsor
- National Taiwan University HospitalUniversity, hospital or other
- Study start
- Oct 2005
- Primary completion
- Sep 2007 (actual)
- Study completion
- Dec 2007 (actual)
- First posted
- 11 Apr 2007 (estimated)
- Results
- Posted 17 Feb 2014
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is to compare intraindividually the functional vision provided by two different posterior chamber intraocular lenses: AMO Tecnis Z9000 and Alcon SA60AT Acrysoft. To see if the aspherical intraocular lenses provide better functional vision than traditional spherical intraocular lenses.
Detailed description
In this prospective study, 20 patients with bilateral catarct presenting for cataract surgery are randomly assigned to recieve an aspherical intraocular lens(AMO Tecnis Z9000) in one eye and a spherical intraocular lens(Alcon SA60AT Acrysof)in the other. All surgeries are performed by one experienced surgeon(Fung-Rong Hu,MD)with clear cornea small incision phacoemulsification and in-the-bag posterior chamber intraocular implantation.
The patients are followed for 3 months, and postoperative contrast sensitivity, contrast acuity, corneal \& total ocular high-ordered aberrations are measured and compared intraidividually between two different IOL groups.
Outcome Measurement:
- Contrast sensitivity testing: measured with spectacle correction for the target distance of three meters using wall-mounted FACT sine-wave grating chart with nine levels of contrast.The graphic contrast sensitivity is recorded as a log functional units on the y-axis and displayed for five spatial frequency targets (1.5, 3, 6, 12, 18 cycles per degree (cpd))on x- axis.
- Contrast acuity testing: measured with spectacle correction for the target distance of three meters using logMAR letter chart(Precision Vision®)represented on a wall-mounted illuminator cabinet.Two types of contrast charts are used, high contrast(Cat.No.2103 SLOAN translucent chart)and low contrast(Cat.No.2132 10% SLOAN translucent chart),and are tested under both photopic and mesopic conditions.
- Pupil diameters: measured by Colvard infrared pupillometer (Oasis. Medical, Glendora, CA, USA )under both photopic and mesopic luminance levels.
- Corneal aberration analysis: performed with TMS-4 (Tomey, Japan).The corneal HOAs are described with Zernike polynomials of 3rd-to 5th- order root-mean-square(RMS)of central 6mm diameter using VOLPro 6.89 software(Fa. Sarver and Associates, Carbondale. Ill, USA).
- Total ocular aberration analysis: performed with a Hartmann-Shack aberrometer(Zywave, Bausch \& Lomb Inc., Rochester, New. York)under maximal mydriasis with Mydrin-P(phenylephrine hydrochloride 0.5% and tropicamide 0.5%, Santen).The wavefront errors were described using Zernike polynomials RMS for total HOA at pupil diameter of 5 mm and 6 mm, primary spherical (Z 4,0) and 3rd-to 5th-order aberration at pupil diameter of 6 mm.
Data Analysis:
- Mann-Whitney U matched-paired test was used with STATA software
- P values of 0.05 or less were considered statistically significant
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- Double blind (participant, outcomes assessor)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| intraocular lens | Active comparator | Device: aspherical intraocular lens, Device: spherical intraocular lenspatients with bilateral clinical significant cataract reisiceved cataract surgeries and recieved spherial intraocuar lens(SA60AT, Alcon) in one eye and aspherical intraocular lens(Tecnis Z9000, AMO)in the other respectively. |
Who may qualify
- Ages
- 45 to 80 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- Bilateral cataracts, eligible for phacoemulsification with primary implantation of a posterior chamber IOL
- Willing and able to comply with scheduled visits and other study procedures
Key exclusion criteria (3 listed)
- Preoperative ocular pathology potentially affect visual acuity. EX: diabetic retinopathy, macular degeneration, corneal opacity, glaucoma, visual field defect...etc.
- Previous ocular surgery. Ex: refractive surgery, vitreoretinal surgery...etc.
- Patients who cannot cooperative with the study procedures
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| aspherical intraocular lensAlso: AMO Tecnis Z9000implantation of aspherical intraocular lenses(AMO Tecnis Z9000)during cataract suregry (small cornea incision phacoemulsification, deliver with Monarch II device, in the bag implantation) | Device | intraocular lens |
| spherical intraocular lensAlso: Alcon SA60AT Acrysofimplantation of spherical intraocular lenses(Alcon SA60AT Acrysof)during cataract suregry (small cornea incision phacoemulsification, deliver with Monarch II device, in the bag implantation) | Device | intraocular lens |
Primary outcome
Best Corrected logMAR Contrast Acuity at Photopic/Mesopic Condition
Time frame: average data of post-op 3rd, 6th, 12th week measurements
Contrast acuity testing was measured with spectacle correction for the target distance of three meters using a logMAR letter chart (Precision Vision®) represented on a wall-mounted illuminator cabinet. Two types of contrast charts were used, high contrast (Cat.No.2103 SLOAN translucent chart) and low contrast (Cat.No.2132 10% SLOAN translucent chart), and these were tested under both photopic (250 Lux) and mesopic (0.5 Lux) conditions. The contrast acuity tested ranges from 20/160 to 20/20(from worse to best), which equals LogMAR(Logarithm of the Minimum Angle of Resolution)0.9 to -0.3. All of the visual acuity and functional vision testing examinations mentioned above were performed by a single ophthalmologist. The outcomes were recorded as average of three post-operative measurments.
Best Corrected Contrast Sensitivity in Photopic Condition
Time frame: average data of post-operative 3rd week, 6th week, 12th week measurements
Contrast sensitivity testing was measured with spectacle correction for the target distance of three meters using a wall-mounted FACT sine-wave grating chart with nine levels of contrast (Stereo Optical Inc.)and five spatial frequency targets (1.5, 3, 6, 12, 18 cycles per degree (cpd)) at 250 lux. The last correct grating seen for each spatial frequency is recorded and translated by the "EYEVIEW™ Functional Analysis Software" into a log contrast sensitivity unit. The outcomes were recorded as average of the three post-operative measurements. ( physiological range of contrast sensitivity: 1.5 cpd : 25~82.5 ; 3 cpd: 30~150 ; 6 cpd: 65 ~ 200 ; 12 cpd: 20 ~130 ; 18 cpd: 6.5 ~ 65 )
2 secondary outcomes
Corneal High-order Aberrations
Time frame: pre-op & averate data of post-op 3rd, 6th, 12th week measurements
Total Ocular High-order Aberrations
Time frame: average data of post-op 3rd, 6th, 12th week measurements
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 17 Feb 2014.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
Related trials for Cataract
Recruiting
Implementing AI-based Glaucoma Screening Within Federally Qualified Health Centers
Glaucoma, Ocular Hypertension
Not yet recruiting
Trial to Investigate the Safety and Effectiveness of the KI-362-US1 (YP2.2VM) Intraocular Lens (IOL) in Adult Participants for Correction of Aphakia Following Cataract Extraction
Aphakia, Postcataract
Not yet recruiting
Effects of Oxygen Cage Support During Cataract Surgery
Cataract
Active, not recruitingObservational study
Age-Related Eye Disease Study (AREDS) Follow-Up
Age-Related Macular Degeneration, Cataract
RecruitingObservational study
Objective Depth-of-Focus Changes During Light Adjustable Lens UV Adjustments
Light Adjustable Lens, Objective Depth of Focus
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Pei-Yuang Su, MD principal investigator
National Taiwan Unoversity Hospital
Fung-Rong Hu, MD study chair
National Taiwan University Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 4 study testing aspherical intraocular lens and spherical intraocular lens in people with Cataract, run by National Taiwan University Hospital at 1 site in Taiwan.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 17 Feb 2014. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Taiwan. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
Yes. Results are posted in the registry (first posted 17 Feb 2014). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Best Corrected logMAR Contrast Acuity at Photopic/Mesopic Condition (time frame: average data of post-op 3rd, 6th, 12th week measurements). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.