Coronary Artery DiseasePhase 2/3NCT00292474
TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent
A Phase 2/3 study testing percutaneous coronary intervention in people with Coronary Artery Disease, run by Boston Scientific Corporation at 1 site in United States.
Trial summary
The ultimate goal of a paclitaxel eluting stent system (TAXUS stent) is to prevent restenosis by blunting the initial response to stent implant injury and sustaining the arrested response until vascular healing has taken place. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary Artery Disease
- What is being tested?
- percutaneous coronary intervention
- Type of treatment
- Medical device
- Could I receive a placebo?
- Yes, some participants may receive a placebo
- How many people
- 1,326 participants
- Where
- 1 siteUnited States
- Study dates
- Mar 2002to Aug 2007
- Phase
- Phase 2/3
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patient is > or = 18 years old
- Eligible for percutaneous coronary intervention (PCI)
- Documented stable angina pectoris (Canadian Cardiovascular Society Classification [CCS] 1, 2, 3, or 4) or unstable angina pectoris with documented ischemia (Braunwald Class IB-C, IIB-C, or IIIB-C), or documented silent ischemia
- Left ventricular ejection fraction (LVEF) of > or = 25%
- Acceptable candidate for CABG
- Patient (or legal guardian) understands the study requirements and the treatment procedures and provides written Informed Consent before any study-specific tests or procedures are performed
Show all 10Show fewer
- Willing to comply with all specified follow-up evaluations
- 1. Target lesion located within a single native coronary vessel 2. Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent 3. Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate) 4. RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate) 5. Target lesion diameter stenosis > or = 50% (visual estimate) 6. Target lesion is de novo (i.e., a coronary lesion not previously treated)
- 7. Target lesion located within a single native coronary vessel 8. Target lesion randomized to treatment with the study device may be composed of multiple lesions but must be completely coverable by one (1) study stent 9. Cumulative target lesion length is > or = 10 mm and < or = 28 mm (visual estimate) 10. RVD of > or = 2.5mm to < or = 3.75 mm (visual estimate) 11. Target lesion diameter stenosis > or = 50% (visual estimate) 12. Target lesion is de novo (i.e., a coronary lesion not previously treated)
- -
Who cannot join
- 1. Known sensitivity to paclitaxel 2. Any previous or planned treatment with a non-study anti-restenotic drug-coated or drug-eluting coronary stent. (Note: previous or planned treatment with heparin or phosphorylcholine coated stents is acceptable, as long as the procedure with the non-study stent meets the protocol defined criteria for staged procedures) 3. Previous or planned treatment with intravascular brachytherapy in the target vessel 4. MI within 72 hours prior to the index procedure and/or CK-MB >2x the local laboratory's upper limits of normal (refers to a measured value on the day of the index procedure) 5. Cerebrovascular Accident (CVA) within the past 6 months 6. Acute or chronic renal dysfunction (creatinine >2.0 mg/dl or >150 µmol/L) 7. Contraindication to ASA, or to both clopidogrel and ticlopidine 8. Leukopenia (leukocyte count <3.5 x 109/liter) 9. Thrombocytopenia (platelet count <100,000/mm3) 10. Active peptic ulcer or active gastrointestinal (GI) bleeding 11. Known allergy to stainless steel 12. Any prior true anaphylactic reaction to contrast agents 13. Known anaphylactoid or other non-anaphylactic allergic reactions to contrast agents that cannot be adequately pre-medicated prior to the index procedure 14. Patient is currently taking colchicine 15. Patient is currently, or has been treated with paclitaxel within 12 months of the index procedure 16. Female of childbearing potential with a positive pregnancy test within 7 days before the index procedure, or lactating, or intends to become pregnant during the study 17. Life expectancy of less than 24 months due to other medical conditions 18. Co-morbid condition(s) that could limit the patient's ability to participate in the study, compliance with follow-up requirements or impact the scientific integrity of the study 19. Currently participating in another investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the endpoints of this study
- -
Trial locations and contacts
1 site in 1 country.
About this study
The ultimate goal of a paclitaxel eluting stent system (TAXUS stent) is to prevent restenosis by blunting the initial response to stent implant injury and sustaining the arrested response until vascular healing has taken place.
The purpose of the TAXUS IV-SR trial is to study the safety and efficacy of the TAXUS Stent under controlled trial circumstances used in the treatment of new coronary artery lesions (heart blockages) This clinical investigation will evaluate the safety and effectiveness of the TAXUS Stent with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier system for treatment of new coronary artery lesions.
Read the detailed description
This was a prospective randomized, double-blind, multicenter safety and efficacy trial. Patients were stratified by presence or absence of medically treated diabetes mellitus and vessel diameter (<3.0 mm or >/=3.0 mm), then randomized 1:1 to receive either the TAXUS Stent or a Control stent. Additional study stents were permitted to optimize outcomes. The study was considered complete (with regard to the primary endpoint) after all patients enrolled had completed the 9 month follow-up.
Enrollment of 1172 patients was planned; 1326 were treated and randomized at 73 centers involving 76 sites by 8 July 2002 with 667 in the TAXUS group and 659 in the Control group.
- Conditions
- Coronary Artery Disease
- Being tested
- percutaneous coronary intervention
- Keywords
- coronary artery disease, percutaneous coronary interventions, stent implant, drug-coated stent
- Medical subject headings
- Coronary Artery Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
percutaneous coronary interventionDevice
| Study group | Role | What they receive |
|---|---|---|
| TAXUS Express | Experimental | Not described Receives: Device: percutaneous coronary intervention |
| Express Bare | Placebo comparator | Not described Receives: Device: percutaneous coronary intervention |
What is being measured
The primary outcome is the main question the study is designed to answer.
The primary objective of this study is to evaluate the safety and effectiveness of the TAXUS Stent System with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier syst
Secondary outcomes (6)
Secondary endpoints include the following:
• Rates of composite MACE and the individual components of MACE (MI, TVR, Cardiac Death), assessed at 1, 4 and 9 months after the index procedure and annually for 5 more years (i.e., 1, 2, 3, 4, and 5 years after the index procedure).
• Stent thrombosis rate
• Target Vessel Failure
• Clinical procedural success
• Binary restenosis rate
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted16 Feb 2006 (estimated)
- Study startMar 2002
- Primary completionAug 2007
- Study completionAug 2007
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- More trials run by Boston Scientific CorporationThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 2/3
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind
- Who is masked
- Participant, Investigator
- Enrolment
- 1,326 participants (actual)
Sponsor and investigators
- Lead sponsor
- Boston Scientific Corporation
- Sponsor type
- Industry (pharma, biotech, devices)
- Investigators
- Gregg W Stone, MD, Principal investigator, Columbia HospitalStephen G Ellis, MD, Principal investigator, The Cleveland Clinic
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT00292474
- Sponsor's protocol ID
- S2004
- Other IDs
- TAXUS IV
- Status last verified
- Oct 2008
- First submitted
- 14 Feb 2006
- Last updated
- 8 Oct 2008
- Results posted
- No
Publications
Wakabayashi K, Mintz GS, Weissman NJ, Stone GW, Ellis SG, Grube E, Ormiston JA, Turco MA, Pakala R, Xue Z, Desale S, Laynez-Carnicero A, Romaguera R, Sardi G, Pichard AD, Waksman R. Impact of drug-eluting stents on distal vessels. Circ Cardiovasc Interv. 2012 Apr;5(2):211-9. doi: 10.1161/CIRCINTERVENTIONS.111.965780. Epub 2012 Apr 10.
PubMed 22496083Ellis SG, Stone GW, Cox DA, Hermiller J, O'Shaughnessy C, Mann T, Turco M, Caputo R, Bergin PJ, Bowman TS, Baim DS; TAXUS IV Investigators. Long-term safety and efficacy with paclitaxel-eluting stents: 5-year final results of the TAXUS IV clinical trial (TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent). JACC Cardiovasc Interv. 2009 Dec;2(12):1248-59. doi: 10.1016/j.jcin.2009.10.003.
PubMed 20129552
Study at a glance
From the registry record, last updated by the sponsor on 8 Oct 2008. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent
- ClinicalTrials.gov ID
- NCT00292474
- Acronym / sponsor ID
- S2004
- Conditions
- Coronary Artery Disease
- Keywords
- coronary artery disease, percutaneous coronary interventions, stent implant, drug-coated stent
- Phase
- Phase 2/3
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 1,326 participants (actual)
- Lead sponsor
- Boston Scientific CorporationIndustry (pharma, biotech, devices)
- Study start
- Mar 2002
- Primary completion
- Aug 2007 (actual)
- Study completion
- Aug 2007 (actual)
- First posted
- 16 Feb 2006 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The ultimate goal of a paclitaxel eluting stent system (TAXUS stent) is to prevent restenosis by blunting the initial response to stent implant injury and sustaining the arrested response until vascular healing has taken place.
The purpose of the TAXUS IV-SR trial is to study the safety and efficacy of the TAXUS Stent under controlled trial circumstances used in the treatment of new coronary artery lesions (heart blockages) This clinical investigation will evaluate the safety and effectiveness of the TAXUS Stent with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier system for treatment of new coronary artery lesions.
Detailed description
This was a prospective randomized, double-blind, multicenter safety and efficacy trial. Patients were stratified by presence or absence of medically treated diabetes mellitus and vessel diameter (<3.0 mm or >/=3.0 mm), then randomized 1:1 to receive either the TAXUS Stent or a Control stent. Additional study stents were permitted to optimize outcomes. The study was considered complete (with regard to the primary endpoint) after all patients enrolled had completed the 9 month follow-up.
Enrollment of 1172 patients was planned; 1326 were treated and randomized at 73 centers involving 76 sites by 8 July 2002 with 667 in the TAXUS group and 659 in the Control group.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, investigator)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| TAXUS Express | Experimental | Device: percutaneous coronary intervention |
| Express Bare | Placebo comparator | Device: percutaneous coronary intervention |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (10 listed)
- Patient is > or = 18 years old
- Eligible for percutaneous coronary intervention (PCI)
- Documented stable angina pectoris (Canadian Cardiovascular Society Classification [CCS] 1, 2, 3, or 4) or unstable angina pectoris with documented ischemia (Braunwald Class IB-C, IIB-C, or IIIB-C), or documented silent ischemia
- Left ventricular ejection fraction (LVEF) of > or = 25%
- Acceptable candidate for CABG
Key exclusion criteria (2 listed)
- 1. Known sensitivity to paclitaxel 2. Any previous or planned treatment with a non-study anti-restenotic drug-coated or drug-eluting coronary stent. (Note: previous or planned treatment with heparin or phosphorylcholine coated stents is acceptable, as long as the procedure with the non-study stent meets the protocol defined criteria for staged procedures) 3. Previous or planned treatment with intravascular brachytherapy in the target vessel 4. MI within 72 hours prior to the index procedure and/or CK-MB >2x the local laboratory's upper limits of normal (refers to a measured value on the day of the index procedure) 5. Cerebrovascular Accident (CVA) within the past 6 months 6. Acute or chronic renal dysfunction (creatinine >2.0 mg/dl or >150 µmol/L) 7. Contraindication to ASA, or to both clopidogrel and ticlopidine 8. Leukopenia (leukocyte count <3.5 x 109/liter) 9. Thrombocytopenia (platelet count <100,000/mm3) 10. Active peptic ulcer or active gastrointestinal (GI) bleeding 11. Known allergy to stainless steel 12. Any prior true anaphylactic reaction to contrast agents 13. Known anaphylactoid or other non-anaphylactic allergic reactions to contrast agents that cannot be adequately pre-medicated prior to the index procedure 14. Patient is currently taking colchicine 15. Patient is currently, or has been treated with paclitaxel within 12 months of the index procedure 16. Female of childbearing potential with a positive pregnancy test within 7 days before the index procedure, or lactating, or intends to become pregnant during the study 17. Life expectancy of less than 24 months due to other medical conditions 18. Co-morbid condition(s) that could limit the patient's ability to participate in the study, compliance with follow-up requirements or impact the scientific integrity of the study 19. Currently participating in another investigational drug or device study that has not completed the primary endpoint or that clinically interferes with the endpoints of this study
- -
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| percutaneous coronary intervention | Device | Express Bare, TAXUS Express |
Primary outcome
The primary objective of this study is to evaluate the safety and effectiveness of the TAXUS Stent System with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier syst
6 secondary outcomes
Secondary endpoints include the following:
• Rates of composite MACE and the individual components of MACE (MI, TVR, Cardiac Death), assessed at 1, 4 and 9 months after the index procedure and annually for 5 more years (i.e., 1, 2, 3, 4, and 5 years after the index procedure).
• Stent thrombosis rate
• Target Vessel Failure
• Clinical procedural success
• Binary restenosis rate
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Oct 2008.
- Derived from this study: PubMed 22496083Wakabayashi K, Mintz GS, Weissman NJ, Stone GW, Ellis SG, Grube E, Ormiston JA, Turco MA, Pakala R, Xue Z, Desale S, Laynez-Carnicero A, Romaguera R, Sardi G, Pichard AD, Waksman R. Impact of drug-eluting stents on distal vessels. Circ Cardiovasc Interv. 2012 Apr;5(2):211-9. doi: 10.1161/CIRCINTERVENTIONS.111.965780. Epub 2012 Apr 10.
- Derived from this study: PubMed 20129552Ellis SG, Stone GW, Cox DA, Hermiller J, O'Shaughnessy C, Mann T, Turco M, Caputo R, Bergin PJ, Bowman TS, Baim DS; TAXUS IV Investigators. Long-term safety and efficacy with paclitaxel-eluting stents: 5-year final results of the TAXUS IV clinical trial (TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent). JACC Cardiovasc Interv. 2009 Dec;2(12):1248-59. doi: 10.1016/j.jcin.2009.10.003.
Related trials for Coronary Artery Disease
Not yet recruiting
Effect of Stress Ball Use During Femoral Arterial Sheath Removal After Coronary Angiography
Femoral Arterial Sheath Removal, Stress Ball
Active, not recruiting
Shockwave™ vs Surgical Endarterectomy for Calcified Severe Common Femoral Artery Stenosis: Comparison of Efficacy, Safety and Long-Term Outcomes
Common Femoral Artery Stenosis, Calcification; Heart
Not yet recruitingPhase 4
Roxadustat and Myocardial Injury After Off-Pump Coronary Artery Bypass Surgery
Coronary Artery Disease, Coronary Artery Bypass Grafting
RecruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
Active, not recruiting
The OCTOBER Trial - European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction (OCTOBER)
Ischaemic Heart Disease, Ischemic Heart Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Gregg W Stone, MD principal investigator
Columbia Hospital
Stephen G Ellis, MD principal investigator
The Cleveland Clinic
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 2/3 study testing percutaneous coronary intervention in people with Coronary Artery Disease, run by Boston Scientific Corporation at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 10 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 8 Oct 2008. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this combined phase mean?
Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.
Phase 3 studies compare the treatment with the current standard treatment or a placebo in a large group, to confirm how well it works and watch for side effects.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
The primary objective of this study is to evaluate the safety and effectiveness of the TAXUS Stent System with 1 ug/mm2 (loaded drug/stent surface area) of paclitaxel incorporated into a slow rate-release formulation of a triblock copolymer carrier syst. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT00292474, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Oct 2008.